Fike System Sensor i3 Sounder and Relay Smoke Detectors A05-0348

File Preview
File Preview
Click below to download for free

Text Preview

C O N V E N T I O N A L D E T E C T I O N and Relay Detectors Available Models Models with thermal and sounder with thermal and Form C relay with thermal and sounder with thermal and Form C relay with thermal sounder and C relay with isolated thermal sounder Form C relay relay synchronization module loop test maintenance module reader tool adapter bracket Overview line of options including 85 dB sounder Form C relay Isolated thermal sensor the i3 feature set design base included terminals to octagonal single and 4 square back or direct to the ceiling Lock to the base cover and maintenance signaling compensation and algorithms sensitivity color LEDs Walk loop testing Sensor i3 sounder and relay smoke detectors apply the guiding principles installation ease intelligence and instant inspection in a series of specialty devices ease Throughout the i3 series installation is simple with its installer base and plug in design The base accommodates a broad range of back box direct mounting options and provides ample space for pre wiring the installation complete the installation the i3 detector plugs into its base with a simple Stop Drop Lock action To reduce the likelihood of nuisance alarms all i3 detectors are equipped both drift compensation and smoothing algorithms These capabilities minimize short and long term causes of nuisance alarms such as RF interference and dust When connected to the 2W MOD2 loop test maintenance module or an Ready panel 2 wire i3 detectors can generate a remote maintenance signal when are in a maintenance or freeze trouble condition To measure the sensitivity of any detector the SENS RDR displays the reading in terms of percent per foot obscura within seconds inspection The i3 line red and green LEDs simplify local status indication dur power up standby alarm maintenance and freeze trouble conditions When in i3 sounder models generate an 85dB temporal tone If connected to the RRS reversing relay synchronization module all i3 sounders on the loop will activate one detector is in alarm Additionally the RRS MOD synchronizes the output of i3 sounders to ensure a clear audible signal the application call for differentiating between a local and a general alarm the i3 offers an isolated thermal model which initiates a local alarm when smoke is detect and a general alarm when the thermal sensor is activated Speci detector shall be a System Sensor i3 model number listed to Laboratories UL 268 for Fire Signaling Systems The detector be a combination photoelectric ther equipped with a sounder model 4WTA B a Form C relay model a combination sounder relay 4WTAR B or an isolated model 4WITAR B detector shall include a mounting base mounting to 31 and 4 inch octago single gang and 4 inch square back Specifications Voltage 12 24 V non polarized 8.5 V 35 V 10 V 35 V Ripple Voltage of applied voltage peak to peak with a plaster ring or direct mount the ceiling using drywall anchors Wiring shall be made by means of screws The detector shall allow pre of the base and the head shall be a type The detector shall have a sensitivity of 2.5 per foot nomi as measured in the UL smoke box The shall be capable of automatically its sensitivity by means of drift and smoothing algorithms detector shall provide dual color LED which blinks to indicate power normal standby out of sensitivity and freeze trouble conditions When in conjunction with the 2W MOD2 2 wire models shall include a signal to indicate the need for at the alarm control panel shall provide a loop testing capability verify the circuit without testing each individually When used in con with the RRS MOD module all sounder models on a loop shall sound one alarms all shall be synchronized all sounders may be silenced from the Current 50 maximum average 50 maximum average Standby Current 100 n a Alarm Current 130 mA limited by control panel 4WTA B 4WTR B 35 mA 4WITAR B 50 mA Contact Ratings n a 0.5 A 30V AC DC C Contact Ratings 30V AC DC Modes Mode up standby of sensitivity trouble LED every 10 seconds every 5 seconds LED every 10 seconds every 5 seconds every 10 seconds Up Sequence for LED Indication LED status indication seconds nominal Terminals AWG including base inches 134 mm diameter inches 51 mm height Weight oz 200 grams Pressure Output dBA models 2WTA B 4WTA B and 4WITAR B only octagonal back box octagonal back box gang back box square back box with a plaster ring mount to ceiling Current mA max limited by control panel mA max limited by control panel mA mA mA mA relay synchronization module loop test maintenance module reader replacement tool adapter bracket Specifications Temperature Range 0 Humidity Range to 95 RH non condensing Sensor 57.2 Trouble 5 Information Wiring Sensor Sales and Service Sensor Headquarters Ohio Avenue Charles IL 60174 800 SENSOR2 630 377 6495 on Demand x3 Sensor Canada 905.812.0767 905.812.0771 Sensor Europe 44.1403.276500 44.1403.276501 Sensor China 86.29.524.6253 86.29.524.6259 Sensor Singapore 65.273.2230 65.273.2610 Sensor Far East 85.22.191.9003 85.22.736.6580 Sensor Australia 613.54.281.142 613.54.281.172 Sensor India 91.11.558.2119 91.11.527.6815 2002 System Sensor The company reserves the right to change product speci without notice

Related Files