VESDA LASERFOCUS 268 and UL 268A Duct File S5198 FM Approved VESDA LaserFOCUS Air Sampling Smoke Detector very early warning smoke detection performance for protection of small business critical environments of 2,500 and 5,000 VLF 500 square feet or less air sampling detection concept works by continually ambient air through sample points in a pipe network entering the unit the sampled air is filtered via the dual filter then it is passed into the detection chamber where scattering technology detects the presence of very small of smoke As the amount of detected smoke increases revolutionary circular Smoke Dial provides the user with instant understanding of a smoke event even from a distance Detector status information is externally via relays or optional interface cards START VESDA LaserFOCUS unrivaled concept provides straight forward installation and commissioning out of the box using proven pre engineered sampling pipe network designs and powerful AutoLearn routines the need for a special interface or software programming tools The AutoLearn function automatically sets alarm thresholds for both smoke and flow levels without the need for a PC or separate programming Custom sampling pipe network designs are supported via the ASPIRE2 calculation program operation the unique circular Smoke Dial provides instant understanding of a smoke event and system status a fault occur the System Fault LED is illuminated To trouble shoot the condition the user simply opens the service door and activates the Instant Fault Finder feature to determine the specific fault condition This can then be passed onto the Fire Service provider ensuring service technicians arrive onsite fully prepared FEATURE Ultrasonic Flow Sensing patent pending used in the LaserFOCUS provides a direct reading of the sampling pipe rate The SonicFlow concept is immune to air temperature and pressure changes and is unaffected by VESDA is the first air sampling smoke detector to use ultrasonic flow sensing Operation Ultrasonic Airflow Sensing Absolute Smoke Detection Pipe Network Designs Alarm Thresholds Dual Stage Air Filtration Recognition Display Fault Finder Smoke Flow Service Access Door Multiple Event Logging in separate logs Offline online configuration capability log up to 18,000 events to 2500 sq ft 250 m2 coverage on VLF 250 to 5000 sq ft 500m2 cover on VLF 500 S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 4615 www fike com No V 1.06.01 Power WHD Rating Conditions Network Inlet Pipe Outputs Access Termination Range Threshold Setting Range Log Smoke Flow Period 24VDC Nominal 18 30 VDC 24 VDC 220 mA nominal 295 mA in alarm VLF 250 24 VDC 410 mA nominal 490 mA in alarm VLF 500 5 8in x 6 7 8in x3 1 2in 245mm x 175mm x 90mm VLF 250 7 8in x 7 1 8in x 3 1 2in 255mm x 185mm x 90mm VLF 500 4.4 lbs 2kg inverted or horizontal Ambient 32 to 104 0 to 40 5 to 95 non condensing area of coverage 2500 sq ft depending on local codes and Maximum pipe length in accordance with pre engineered designs for custom networks use Pipe Modeling Design Tool ASPIRE2 and standards both American and metric standard pipe sizes without use of diameter 1 in 25mm diameter IPS 3 4 in 21mm Form C relays Fire 1 Action Fault Contacts rated 2A 30VDC max x 1 in 25mm cable entries 1 rear entry 2 top entry Terminals 30 12AWG 0.2 2.5 mm2 in Terminal Block Connections diagram plus an RS232 Port General Purpose Input GPI interface offers Reset Standby Alarm set 1 Alarm set 2 and External Input functions obs ft 0.025 20.00 obs m Action 0.008 0.625 obs ft 0.025 2.00 obs m 1 Fire 2 0.008 6.25 obs ft 0.025 20.00 obs m Alarm Delays 0 60 seconds Alarm Threshold Setting Either time or GPI based Alarm State Indicators Level Indicator Disable and Test controls and Disabled Indicators Fault Finder and Flow AutoLearn Controls to 18,000 events time and date stamped in separate non volatile logs smoke level flow level detector status and faults set acceptable alarm thresholds for both smoke and flow 15 minutes maximum 15 days default 14 days AutoLearn thresholds are NOT changed from pre set values years BLOCK CONNECTIONS GPI GPI Display TX Display RX Display Common Ground Display Power Display Power Power Return 0 VDC Power in 24 VDC Power Return 0 VDC Power Out 24 VDC NC Common NO NC Common NO NC Common NO relay relay 1 relay power supply unit next detector more than 1 detector per Power Supply Unit display provided to the user includes a Dial and alarm and status indicators the field service access door is open user has access to the RESET Fire Test AutoLearn Instant Fault Finder functions When the Fault Finder function is activated the Dial converts to a fault indicator with dial segment numbers correspond to the listed below OF FAULT INDICATORS External Device PSU Filter Aspirator Interface Card Field Wiring High Flow Low Flow Auto Learn Fail N A 10 Detector Failure INFORMATION VLF 250 VLF 500 VIC 250 500 Interface Card page is left blank intentionally Fike Corporation All Rights Reserved No V 1.06.01 July 2005 Specifications are subject to change without notice document may not be reproduced in whole or in part by any means without the prior express written permission of the copyright owner Copyright 2003 Vision Security Pty Ltd ABN 008 009 514 The manufacturer reserves the right to change designs or specifications without obligation and without further notice VESDA LaserPLUS LaserSCANNER LaserCOMPACT VESDAnet VESDAlink ASPIRE AutoLearn VSM VConfig and InfoWORKS are trademarks used under by the distributor

Related Files