Fike Weatherproof Evac Signals P 1 61 01

File Preview
File Preview
Click below to download for free

File Data

Name fike-weatherproof-evac-signals-p-1-61-01-5816479023.pdf
Type PDF
Size 799.65 KB
Downloads

Text Preview

WEATHERPROOF EVACUATION SIGNALS Fike Weatherproof Evacuation Signals manufactured by Gentex are a low profile strobe horn or horn strobe combination that offer visible and or audible alarms These durable horns offer a or synchable temporal three in 2400Hz and mechanical tone a chime well as a whoop tone All tones are easy for the professional to change in the by using switches Units are shipped from the factory on the temporal lower mode and come standard with a rugged die cast metal mounting plate Fike Weatherproof Evacuation Signals have a minimal operation current and minimum flash rate of 1Hz regardless of input voltage Weatherproof Evacuation Signals are also equipped with the SuperSlide to test supervision Included with shipment of the unit is a weatherproof and must be used together to meet the UL outdoor listing are UL 464 UL 1638 listed for use with fire protective systems and warranted for three years from date of purchase FEATURES SPECIFICATIONS Prewire Entire System Then Install see Gentex Technical 015 Signals Ease of Supervision Testing Super Listed for UL1638 outdoor use True Evacuation Tone Switch Selection for High or Low Switch for Chime Whoop and 2400Hz Tone Switch for Continuous or Temporal not available on whoop tone Tamperproof Re entrant Grill Wide Voltage Range 16 33 VDC or Separate Horn and Strobe Functions Synchronize Strobe and or Horn by the AVS Series Control MODELS used with the outdoor Lower Installation and Operating Input Terminals 12 to 18 AWG Rugged Die Cast Metal Mounting Available in Red or Off White 75 Candela Strobe Meets ADA Requirements Operating Temperature to 120 0 to 49 Indoor to 150 35 to 66 Red White Red White Horn Strobe Red Strobe and Horn Strobe Shipped the Weatherproof Enclosure Americans with Disabilities Act 4.28.3 BFP City of Chicago BS A MEA 285 91 E XVI CSFM 7135 0569 122 Horn Strobe Weatherproof Outdoor NFPA 72 UL 464 UL 1638 Must order the enclosure when using the Evacuation in an outdoor application P N P N Current Draw 24VDC S 10th Street P O Box 610 Blue Springs Missouri 64013 0610 U S A 816 229 3405 816 229 0314 www fike com 10 ft per High 10 ft per Low mA Mode 24v 33v 16v 24v 33v 16v 24v 33v 3 2400Hz 3 Mechanical 3 Chime 2400Hz Mechanical 80 Chime The sound output for the temporal 3 tone is rated lower since the time the horn is off averaged into the sound output rating While horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode Gentex does not recommend using a or pulsing signaling circuit with any of our strobe products Operating the horn in this mode at this voltage will result in not meeting the minimum UL reverberant sound level required for public mode protection service These settings are acceptable only for private mode fire alarm use Use the high dBA setting for public mode application not when using the chime tone The chime tone is always private mode SuperSlide Locations Position Temp Cont Temp Cont Diagram Fike Weatherproof Evacuation Signals with AVS Synchronization Module AND ENGINEERING SPECIFICATIONS audible and or visible signal shall be a Gentex Weatherproof Evacuation Signal or approved equal and shall be listed by Laboratories Inc per UL 1638 and or UL 464 The notification appliance shall also be listed with the State Fire Marshall CSFM and the Bureau of Standards and Appeals NYC notification appliance combination audible visible and audible units only shall produce a peak sound output of or greater as measured in an anechoic chamber The signaling appliance shall also have the capability to silence the signal while leaving the visible signal energized with the use of a single pair of power wires Additionally the user be able to select either continuous or temporal tone output with the temporal signal having the ability to be audible visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or greater regardless of input voltage The appliance shall also be capable of meeting the candela requirements of the ADA 75Cd appliance shall be polarized to allow for electrical supervision of the system wiring The unit shall be provided with a bracket with terminals with barriers for input output wiring and be able to mount to a single gang or double gang or double workbox without the use of an adapter plate The unit shall have an input voltage range of 16 33 volts with direct current of full wave rectified power appliance shall be capable of test supervision without disconnecting wires Also the appliance shall be capable of to a surface back box The Weatherproof Evacuation Signal unit must be used with the outdoor enclosure to UL outdoor listing Fike Corporation All Rights Reserved No P 1.61.01 May 2004 Specifications are subject to change without notice

Related Files