Autocall 4010ES Basic Addressable Fire Detection and Control Unit Modules and Accessories; International

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Fire Control Units Basic Addressable Fire Detection and Control Unit Modules and Accessories ULC Approved CSFM Listed FM with Autocall ES Net fire alarm network system features Models available with Color ES Touch Screen Display or Monochrome 2 x 40 Character Display Capacity for up to 1000 addressable IDNet points up to 127 VESDA Aspiration points up to 2000 points of annunciation and up to 20 and external card addresses CPU assembly includes dedicated compact flash memory for on site information storage and convenient Ethernet service port 8 A power supply with up to 2 A of auxiliary power and battery capacity for up to 110 Ah batteries UL 50 Ah maximum with battery shelf in two bay control cabinet Four onboard Class A or B 3 A notification appliance circuits NACs one programmable auxiliary relay output rated for 2 A at 32 VDC IDNet addressable device communications that support TrueAlarm sensors and IDNet communications monitoring and control with an electrically isolated output channel allowing use with shielded or unshielded twisted or untwisted single pair wiring providing dual short circuit isolating output loops Remote annunciator module support with remote unit interface RUI port either Class B or Class A operation 48 LED panel mount annunciation provides 40 red and 8 yellow LEDs select models optional LED kits are available for LED configurations Available with InfoAlarm Command Center expanded content user requires a two bay cabinet Main System Supply 2 and door mounted modules and options include City Connect Module Alarm relay module Battery brackets for seismic area protection block space modules include Fire alarm network interface card NIC for ES Net Peer to peer network communications supports either Class B or Ethernet connectivity options include ES Net NIC and BACpac Ethernet X operation Dual RS 232 Module for printer or third party interface VESDA Air Aspiration High Level Interface Serial DACT 8 Point Zone Relay Module 4 Point Auxiliary Relay Module with or without Feedback Additional IDNet addressable channels Eight point zone relay module Class A or B You can select each point an IDC input or relay output Class A IDCs require two points out and one return Relays rated for 2 A at 30 VDC resistive as normally open or closed 1 2 Bay 4010ES Fire Control Panel 2x40 Monochrome LCD Display Agency Listing UL 864 Control Units System UOJZ Control Unit Accessories Fire Alarm UOXX Control Units Releasing Device Service Smoke Control System Equipment UUKL UL 1076 Proprietary Alarm Units APOU UL 1730 Smoke Detector Monitors and Accessories UULH UL 2017 Emergency Alarm System Control Units CO detection FSZI Equipment Management QVAX ULC S527 Control Units System Fire Alarm UOJZ7 Control Unit System Fire Alarm UOXX7 Control Units Releasing Service SYZV7 ULC S559 Central Station Fire Alarm System Units DAYR7 ULC ORD C1076 Proprietary Burglar Alarm System Units APOU7 ULC ORD C100 Smoke Control System Equipment UUKL7 This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7120 2269 0546 7272 2269 0509 7272 2269 0537 7165 2269 0541 7165 2269 0542 and 7165 0026 0369 for allowable values and or conditions concerning material presented in this document to Tables 3 and 4 for applicable listings at time of publication Additional listings may be applicable contact your local product supplier for the latest status For specific product listings refer to 2 and 3 AC4010 0004 Rev 27 11 2021 Basic Addressable Fire Detection and Control Unit Modules and Accessories series fire detection and control units provide leading edge installation operator and service features for customer applications in the mid addressable fire alarm systems market An onboard Ethernet port provides fast external system communications to expedite installation and activity Dedicated compact flash memory archiving provides secure on site system information storage of electronic job configuration files design A variety of functional modules are available to meet specific system requirements With the selections control units are for either stand alone or networked fire control operation Command Center options provide convenient expanded display content Refer to data sheet InfoAlarm Command Center for the 4010ES Fire Control Unit AC4010 0009 for more information with the following Autocall remotely located modules 4098 9757 QuickConnect TrueAlarm smoke sensors 4009 IDNet NAC Extenders 4009A A4081 Series 110 Ah Battery Chargers 4100 7400 Series Graphic Annunciators A4606 9102 Remote LCD Annunciator and A100 9400 Series Remote ES Touch Screen Displays and A100 9400 Series Remote InfoAlarm Command and A602 Series Status Command Units SCU and Remote Command Units RCU Annunciators description Mounting box provides convenient stud markers for drywall thickness and nail hole knockouts for quicker mounting Includes smooth box surfaces for precise local cutting of conduit entrance holes The hinged user interface panel easily opens for internal access NACs mount directly on power supply assemblies providing minimized wiring loss compact size and readily accessible terminations Modules are power limited except where noted such as relay modules Doors include tempered glass inserts boxes and doors are available in platinum or red Box and door or retainer assemblies are included with basic control unit assemblies Cabinet assembly is rated NEMA 1 and IP 30 Cabinet assembly design is seismic tested and is certified to IBC and CBC standards and to ASCE 7 categories A through F requires battery brackets detailed on data sheet Battery Brackets for Seismic Activity Applications AC2081 0019 unit hardware Master Controller and Main System Supply 2 the Master Controller and Main System Supply 2 in the upper section of the 4010ES cabinet See Figure 10 for more information Block Space Option Cards the 4010ES Block Space Option Cards to the left of the 4010ES Main System Supply 2 In two bay cabinets mount the block space option cards the 4010ES ESS 4010ES options the 4010ES City Connect module or the optional Alarm Relay module directly to the Main System Supply 2 These options are mutually battery compartment located in the bottom of the 4010ES cabinet accepts two batteries without interfering with expansion module space feature summary TrueAlarm individual analog sensing with front panel information and selection access Dirty TrueAlarm sensor maintenance alerts service and status reports including almost dirty TrueAlarm magnet test indication appears as a distinct test abnormal message on display when in test mode TrueAlarm sensor peak value performance report Install Mode allows grouping of multiple troubles for uninstalled modules and devices into a single trouble condition Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring Recurring Trouble Filtering allows the control unit to recognize process and log recurring intermittent troubles such as external wiring ground faults only sends a single outbound system trouble to avoid nuisance communications WALKTEST silent or audible system test performs an automatic self resetting test cycle peripheral devices 4010ES is compatible with an extensive list of remote peripheral devices including printers and both conventional and addressable devices TrueAlarm analog sensors 2 AC4010 0004 Rev 27 11 2021 Basic Addressable Fire Detection and Control Unit Modules and Accessories device control 4010ES provides standard addressable device communications for IDNet compatible devices Using a two wire communications circuit individual such as manual fire alarm stations TrueAlarm sensors conventional IDC zones and sprinkler waterflow switches interface to the addressable to communicate their ident

Related Files