Autocall 4100 Series Graphic Annunciator Modules; LED Switch Modules and 24 Point I O Graphic Module

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Approved Accessories LED Annunciators Series Graphic Annunciator Modules LED Switch Modules and 24 Point I O Graphic modules for LED and switch control of custom graphic panels including A100 7401 24 Point I O Graphic Modules with points selectable as switch inputs or LED outputs A100 7402 64 Switch and 64 LED Driver Module with 32 on board LED A100 7403 32 Point LED Driver Modules A100 7404 32 Point LED Switch Input Modules compatibility For use with Autocall 4007ES 4010ES and 4100ES series fire alarm units door mounting options are available Semi flush or surface mount cabinets in beige or red with or without a Interface modules can be mounted in the same cabinet as the graphic or mounted nearby Plate mounted for mounting in cabinet by others Interface modules are UL listed for use in agency listed custom graphic panels and status supervision Supervised remote unit interface communications RUI require a twisted wire pair some applications may require shields to the alarm control unit power is supplied via a second wire pair Multiple annunciator module types can be connected to same wiring Convenient wiring connections are via pluggable terminal blocks listed to Standard 864 for Fire Detection and Control UOJZ Smoke Control Service UUKL Control remote annunciator graphic control modules complement 4007ES 4010ES and 4100ES and other installed legacy panels providing LED lamp relay drivers and switch inputs to allow custom displays to be designed for specific facility requirements such as smoke control UUKL systems Wiring is minimized by signaling line SLC communications that also provides supervision the event of communications loss a trouble will be displayed at fire alarm control panel and can also be identified at the remote if desired Flexibility packaging flexibility these modules are plate mounted allowing with vended graphics assemblies These modules also convenient terminal block wiring connections and use compact cable connectors for multiple module interconnection 1 Fire Alarm Control Unit Connected to a Graphic Annunciator and a Remote LCD Annunciator This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7120 2269 0546 for allowable and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 7 01 2020 Series Graphic Annunciator Modules LED Switch Modules and 24 Point I O Graphic Module Control Module Descriptions 24 Point I O Graphic Module 24 Points selectable as either a switch input or a lamp relay driver output Switch monitoring includes unsupervised supervision for opens supervision for opens or shorts and supervised monitoring of HOA hand off auto Switches can be momentary or maintained 2 position or 3 position maximum distance is 2500 ft 762 m or 65 from the module Each LED lamp relay driver is rated at 150 mA 24 VDC per point inrush is current limited for compatibility with incandescent bulbs relays need to diode suppressed at the relay coil maximum distance is 600 ft 183 m or 2 from the module LED lamp relay driver outputs are supervised for open circuits and can be set as on continuous or pulsed at a slow or fast rate Additional inputs are included for communicating a remote power supply trouble and for lamp testing the module can also be configured to provide indication of communications loss 64 64 LED Switch Controller Module Support for up to 64 switches and 64 LEDs switches are unsupervised Includes 32 LED driver outputs on board for direct LED connection Full capacity is achieved by using a A100 7403 32 Point LED Driver Module and two A100 7404 32 Point Switch Modules Multiplexed LED drivers provide 40 mA peak 5 mA average 60 Hz rate 12.5 duty cycle for direct LED drive and can be steady on or slow or fast LEDs are supervised for open circuits LED and switch module connections are supervised LEDs or switches can be up to 25 ft 7.6 m or 3 from module 32 Point LED Driver Module Provides an additional 32 LED drivers for use with the A100 7402 Controller LED output is the same as for the A100 7402 32 Point Switch Module Monitors momentary or maintained 2 or 3 position switches Switch position sampling is multiplexed at a 60 Hz rate 40 mA maximum 1 mA average 2 Rev 7 01 2020 Series Graphic Annunciator Modules LED Switch Modules and 24 Point I O Graphic Module Mounting Reference 2 mounting reference Annunciator mounting plate 1 A100 7402 LED switch controller A100 7403 32 point LED driver A100 7404 32 point switch modules mounting plate 2 24 point I O graphic modules 3 Rev 7 01 2020 Series Graphic Annunciator Modules LED Switch Modules and 24 Point I O Graphic Module 1 System Type select one Selection mounted graphic modules modules only plate mounted addition modules only Point I O Graphic Module LED Switch Controller Point LED Driver Module Point Switch Input Module 2 Graphic Modules Information is on dedicated mounting plates up to 3 per plate Rules A100 7402 64 64 LED Switch Controller mounted per plate the same plate can mount A100 7403 32 Point LED Driver Module and two A100 7404 32 Point Switch Input mounting plate requires 2 units of space 1 plate per 2 unit cabinet 2 plates per 4 unit 3 plates per 6 unit cabinet Select as required refer to Module Mounting Reference for panel mounting dimensions 4100 series graphic modules are available internally mounted and UL listed in custom graphic annunciator panels and custom graphic smoke annunciators from Space Age Electronics Inc website www 1sae com 3 Package Size Finish and Trim Options select as required if A100 8401 assembly box with glass door retainer finish option only no door Cabinet Dimension Reference See Autocall Annunciator Cabinet Reference for additional information 527 mm 921 mm 1324 mm 654 mm Width 4 Cabinet Dimensions Depth Width 108 mm 675 mm 4 Rev 7 01 2020 Series Graphic Annunciator Modules LED Switch Modules and 24 Point I O Graphic Module 24 Point I O Module current 64 64 LED Switch Per Output Requirements Temperature Humidity Information 5 Annunciator specifications to 32 VDC 24 VDC nominal from fire alarm control unit and Alarm 78 mA all connected LED lamp relay currents and all switch currents mode 12 mA when closed per switch for open circuit mode 5 mA open 12 mA closed per switch for open or short mode 4 mA open 8 mA closed per switch mode 12 mA on 8 mA off 4.5 mA center position to individual control panel and annunciator data for additional RUI compatibility information 67 mA all switch loads 285 mA with 64 total LEDs on all switch loads current 1 mA average up position 0.5 mA average down position external annunciator communications line SLC to 31 total remote RUI devices to 20 internal and external card to 10 remote RUI devices twisted wire pair some applications may require shields AWG 0.82 mm2 to 12 AWG 0.82 mm2 to 3.31 mm2 wires for 24 VDC system power to 14 AWG 0.82 mm2 to 2.08 mm2 dedicated earth ground connection to the electrical box is required for proper ESD and EMI wire in accordance with NFPA 72 and National Electrical Code NEC F to 120 F 0 C to 49 C to 93 RH non condensing 90 F 32 C maximum to Field Wiring Diagram 841 802 connections are terminal blocks Annunciator Cabinet Reference

Related Files