Autocall 4100ES Addressable Fire Detection and Control Basic Panel Modules and Accessories

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Fire Control Units Addressable Fire Detection and Control Basic Panel Modules and Accessories ULC CSFM Listed FM NYC Fire Approved refer to data sheet AC4100 0061 Electrically isolated output IDNet 2 two loop and IDNet 2 2 four loop with short circuit isolation output loops allowing use with shielded or unshielded twisted or untwisted single pair wiring Fire Alarm Network Interfaces DACTs city connections and up to five ports for printers and terminals IDNAC signalling line circuits SLCs for addressable appliance control Alarm relays auxiliary relays additional power supplies IDC modules expansion modules VESDA Air Aspiration Systems interface ASHRAE BACnet Interface LED switch modules and panel mount printers Emergency communications systems ECS equipment 8 channel audio or 2 channel analog audio 8 point zone relay module each point is selectable as an IDC input or output Class A IDCs require two points one out and one return rated for 2 A 30 VDC resistive and configurable as either open or normally closed Compatible with Autocall remotely located 4009 IDNet NAC Extenders to ten for each IDNet SLC information UL 864 Fire Detection and Control UOJZ Smoke Control Service Releasing Device Service SYZV Emergency Communication Relocation Equipment UOQY UL 1076 Proprietary Alarm Units Burglar APOU UL 2017 Process Management Equipment QVAX Emergency Alarm Control Units FSZI UL 1730 Smoke Detector Monitor UULH UL 2572 Mass Notification Systems PGWM CAN ULC S527 Control Units for Fire Alarm Systems UOJZ7 Releasing Service SYZV7 CAN ULC S559 Central Station Fire Alarm System Units DAYR7 ULC ORD C1076 Proprietary Burglar Alarm Units and Systems APOU7 ULC ORD C100 Smoke Control System Equipment UUKL7 Feature Summary provides dual configuration programs Two programs allow for optimal system protection and commissioning with one active program and one reserve Downtime is reduced because the system stays running during based programmer features Convenient front panel accessed Ethernet port for quick and easy of site specific programming Modifications can be uploaded as well as downloaded for greater flexibility Firmware enhancements are made through software downloads to the flash memory interface features TrueAlarm individual analog sensing with front panel information and access Dirty TrueAlarm sensor maintenance alerts service and status including almost dirty 1 4100ES Cabinets are with one two or three bays Controller top bay Models available with Color ES Touch Screen Display shown in Figure Monochrome 2 line x 40 Character Display or Monochrome Display 32 Bit Master Controller with color coded operator interface including switches for high confidence feedback Dual configuration program CPU convenient service port access and for up to 3000 addressable points CPU assembly includes 2 GB dedicated compact flash memory for on system programming and information storage ES Power Supply ES PS and charger with onboard alarm relay auxiliary power output and provisions for one 4 in 10 in or two 4 in x 5 in compatible option cards such as IDNet2 device interface Conventional NAC or Addressable SLC modules refer to 579 1288AC installation instructions for details compatibility with Autocall ES Net Fire Alarm Network addressable interfaces include 250 point addressable IDNet 2 SLC channel with electrically isolated short circuit isolating loops that supports TrueAlarm analog and IDNet communications monitoring and control devices Remote annunciator module support through RUI remote unit communications port modules include Building Network Interface Module BNIC for Ethernet connectivity TrueAlarm magnet test indication appears as distinct test abnormal This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7165 2269 0542 for allowable and or conditions concerning material presented in this document Additional listings may be applicable contact your local Simplex product supplier for the latest status Additional listings may applicable contact your local product supplier for the latest status AC4100 1031 Rev 11 11 2021 Addressable Fire Detection and Control Basic Panel Modules and Accessories on display when in test mode TrueAlarm sensor peak value performance report Install Mode allows grouping of multiple troubles for uninstalled and devices into a single trouble condition typical with future expansion with future equipment and devices grouped into single trouble operators can more clearly identify events from the and occupied areas Module level ground fault searching assists installation and service by and isolating modules with grounded wiring Recurring Trouble Filtering allows the panel to recognize process log recurring intermittent troubles such as external wiring ground but only sends a single outbound system trouble to avoid communications WALKTEST silent or audible system test performs an automatic self test cycle Series Fire Detection and Control Panels provide extensive operator and service features with point and module suitable for a wide range of system applications An on Ethernet port provides fast external system communications expedite installation and service activity Dedicated compact flash archiving provides secure on site system information storage of job configuration files design wide variety of functional modules are available to meet specific requirements Selections allow panels to be configured for either or Networked fire control operation InfoAlarm Command options provide convenient expanded display content detailed data sheet AC4100 1045 Bay Description Master Controller Bay top includes a standard multi featured ES supply the master controller board expansion space for optional and operator interface equipment Expansion Bays include a Power Distribution Interface PDI for 4 in x 5 in flat design option modules and also accommodate modules Battery Compartment bottom accepts two batteries up to 50 to be mounted within the cabinet without interfering with module 2 identifies bay locations using a three bay cabinet for reference 2 4100ES Module Bay Reference 2 AC4100 1031 Rev 11 11 2021 Addressable Fire Detection and Control Basic Panel Modules and Accessories Description Boxes can be close nippled each box provides convenient stud for drywall thickness and nail hole knockouts for quicker Smooth box surfaces are provided for locally cutting conduit entrance exactly where required The latching dress panel retainer assembly easily lifts off for internal NACs can be mounted directly on power supply assemblies minimized wiring loss compact size and readily accessible Peripheral Devices 4100ES is compatible with an extensive list of remote peripheral including printers CRT keyboards up to five total and both and addressable devices including TrueAlarm analog and TrueAlert addressable appliances Controller Bay Module Details Controller and Motherboard Master Controller mounts in Slot 2 of a two slot motherboard and one Class B or Class A RUI communications channel for isolated or un isolated operation Packaging supports traditional 4100 style motherboard with daughter Slot 1 of the motherboard is primarily for an optional network interface Modules are power limited except as noted such as relay modules The NEMA 1 IP30 box is ordered separately and available for early Doors are available with tempered glass inserts or solid boxes and are available in platinum or red Boxes and do

Related Files