Autocall Audible Visible Notification Appliances; Multi-Tone Horn Strobe with 520 Hz Output, Non-Addressable

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM Notification Appliances Notification Appliances Multi Tone Horn Strobe with 520 Hz Output Non 24 VDC multi tone multi candela horn strobes provide Multi candela xenon strobe with synchronized 1 Hz flash rate jumper as 15 30 75 110 135 or 185 cd Per appliance tone selection of 520 Hz Horn Broadband Horn Bell High Low Slow Whoop or Siren selected using an on board Switch refer to Specifications 520 Hz tone is compliant with NFPA 72 Low Frequency Signal for Sleeping Areas Operation is selectable for SmartSync two wire control or free run Tone output level is selectable as high or low Diode polarized input for connection to reverse polarity supervised Appliance Circuits NACs Compatibility with ADA requirements refer to Installation Reference Electrical test point access without removing cover two wire control of audible and visible notification provides Control of Horn Bell and High Low tones as Temporal Pattern March pattern or on continuously controlled separately from visible on the same circuit Control of Slow Whoop Siren and Chime tones as synchronized signals when receiving SmartSync continuous commands SmartSync March Time pattern is selectable per appliance to produce BPM or 20 BPM Visible appliances on the same SmartSync circuit operate at a 1 Hz flash rate Refer to Synchronized Strobes for SmartSync control list and additional information Strobe operation is listed to UL Standard 1971 and ULC Standard S526 Horn operation is listed to UL Standard 464 and ULC Standard S525 design features include Rugged high impact flame retardant thermoplastic housing in red with letters or white with red letters with clear lens available with FEU ALERT FEU FIRE or blank lettering Separate covers are available to change application type on site or replacement covers can be easily removed without disturbing the housing and avoiding trouble conditions A separate mounting plate allows wiring to be completed before is mounted use with single gang double gang or 4 inch box flush or surface mount In out wiring terminals for 18 AWG to 12 AWG Optional mounting adapters are available to cover surface mounted boxes and to adapt to Autocall 2975 9145 boxes 1 Multi Tone A Vs are Available in with White Lettering and White with Red Lettering non addressable multi tone multi candela horn a flexible selection of output tones and strobe intensity for alarm audible notification Tone selection output level and strobe is set per appliance allowing notification needs to be tailored to area requirements Refer to Specifications Tone Selection Switch selection determines the local tone choice A separate DIP position allows selection of a standard or a high output sound selectable appropriate to the location See Specifications two stage alarm applications DIP Switch selection per appliance allows the SmartSync March Time input to be produced as 60 BPM or 20 BPM The 20 BPM rate typically required for Canadian two stage alarm applications as the followed by the Temporal Pattern Two stage alarm operation a 4010 4010ES 4100ES or 4100U as the control panel alarm operation requires a 4010ES 4100ES or 4007ES as the panel See Table 7 for functional limitations by tone type mounting horn strobes can be semi flush or surface mounted on a single gang double gang or 4 square 102 mm electrical box accessories are available to increase mounting and application This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7125 2269 0520 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 7 03 2021 Notification Appliances Multi Tone Horn Strobe with 520 Hz Output Non Addressable Application Selection selection of visible notification is dependent on occupancy location local codes and proper applications of the National Fire Alarm Code NFPA ANSI A117.1 the appropriate model building code BOCA ICBO or SBCCI and the application guidelines of the Americans with Disabilities Act Strobes Strobes When multiple strobes and their reflections can be seen from one location synchronized flashes reduce the probability of photo reactions as well as the annoyance and possible distraction of random flashing The multi candela strobes of these multi tone horn strobes synchronized by the controlling SmartSync operation NAC Two Wire Control operation mode allows a two wire circuit to provide the ability to activate both the multi tone horn and strobe on the same NAC and allow the multi tone horn to be silenced while the strobe remains flashing The multi tone horn operates as on until silenced while the strobe is on until reset Control Sources 4007ES Hybrid 4010ES 4100ES Fire Alarm Control Panels refer to individual product data sheets for more information 4009 IDNet NAC Extender refer to data sheet AC4009 0002 SmartSync Control Module SCM A4905 9938 refer to data sheet AC4905 0003 SmartSync compatible notification appliances include separate multi tone horns and combination multi tone horn strobe notification Selection 1 Multi Tone Multi Candela Horn Strobes Color Wording cover and mounting plate separately with Cover 2 Separate Mounting Plate Required when ordering model 49CMTV APPLW BA BA indicates model is available either with or without the BA suffix Model numbers ending in BA APPLW models and separate mounting are assembled in the USA plate select color to match cover 3 Separate Covers Required when ordering model 49CMTV APPLW BA Only 4 Mounting Adapters mount red adapter skirt mount white adapter skirt to cover 1 1 2 deep surface boxes Plate red for mounting to Autocall 2975 9145 box typically for may be mounted vertical or horizontal mounting box requires Adapter Plate A4905 9931 H x 5 W x 1 D 136 mm x mm x 41 mm Total depth with 3 79 mm 5 x 5 x 0.060 Thick 211 x 146 mm x 1.5 mm x 5 x 2 D 200 mm x 130 x 70 mm 5 Synchronization Control Module Control Module Class A or Class B in 4 square box for use with control not providing SmartSync control x 4 x 1 D 102 mm x 105 mm x 32 mm 2 Rev 7 03 2021 Notification Appliances Multi Tone Horn Strobe with 520 Hz Output Non Addressable Reference Voltage Range Loading Range Range Instructions Hz Horn Horn Whoop Hz Horn and High Low Horn Bell Chime Slow and Siren 6 General Specifications VDC to 33 VDC Special Application of 13 A49CMT Series appliances per NAC to 122 F 0 to 50 C to 93 non condensing 104 F 40 C blocks on mounting plate for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires per terminal for wiring for A49CMTV Series Horn Strobes for A49CMP Mounting Plates 7 Tone Characteristics Hz tone 600 3000 Hz signal Bell tone modulated tones with fundamentals of 1000 Hz and 800 250 ms duration each 520 Hz to 1200 Hz sweep with 2 s duration 600 Hz to 1200 Hz to 600 Hz sweep with 2 s duration signal with a peak and decay time of 1 s compatible with control panel SmartSync for operation as Temporal Code 3 Time selected at appliance for 20 or 60 or Continuous operation that operate as Continuous with with control panel SmartSync 8 TrueAlert Multi Tone Horn Strobe Current Ratings

Related Files