Autocall Audible Visible Notification Appliances, Weatherproof Ceiling Mount Multi-Candela Horn Strobe, Model Series A49AV

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC Listed ES Addressable Notification Appliances Notification Appliances Weatherproof Ceiling Mount Multi Candela Horn Model Series A49AV Mount Addressable Visible A V Notification Appliances individually addressed audible visible notification appliances that power supervision and control signals from an Autocall fire control panel providing IDNAC signaling line circuits SLCs LED Xenon tube strobes devices are interoperable on the same IDNAC addressed and controlled multi candela TrueAlert ES audible visible notification appliances provide Multi candela xenon strobe with synchronized 1 Hz flash rate and with programmable from the control panel or jumper selected the appliance as 110 cd 135 cd or 185 cd Advanced addressable notification controlled by IDNAC SLCs IDNAC SLCs provide regulated 29 VDC to allow horns to operate with current Wiring supervision to each appliance to allow T tap connections for B circuits to simplify wiring Class A circuits require in out wiring Self Test Mode uses an on board sensor to detect the horn output and the status to the control panel TrueAlert Device Reports at the control panel detailing appliance point custom label type and candela setting See an example in TrueAlert reports reference Magnet Test diagnostics to assist checkout and testing of the and wiring Remove the cover to access the electrical test point Compatibility with ADA requirements see Installation reference Strobe operation is listed to UL Standard 1971 and ULC Standard Horn operation is listed to UL Standard 464 and ULC Standard indicator and Magnet Test feature Appliance LED can be selected to display each polling cycle to indicate supervision When the controller is in diagnostic mode the Magnet Test pulses the to indicate appliance address and can also be set to briefly flash strobe and sound the horn design features Rugged high impact flame retardant thermoplastic housing available a variety of colors and lettering Separate covers are available for replacement or to change the type on site Covers can be easily removed without disturbing the connected avoiding trouble conditions In out wiring terminals for 18 AWG to 12 AWG Optional red wire guards see Product selection notification appliance horn Harmonically rich output sound for either coded or steady operation Horns sound as Temporal Code 3 March Time pattern or Temporal Code 4 controlled separately from visible on the same two wire circuit Selectable March Time rates of 20 beats per minute bpm 60 bpm 120 bpm Output is high or low 5 dBA difference selectable at the appliance or the controller with FACP mode selected at the appliance 1 ES Addressable A V application reference selection of visible notification is dependent on occupancy and local codes ES operation advantage ES addressable appliances on IDNAC SLCs separate visible and audible notification using a single two circuit that also confirms connection to the individual notification electronic circuit This operation increases circuit supervision by providing supervision that extends beyond the appliance connections current usage on IDNAC SLCs IDNAC SLCs a constant 29 VDC source voltage is maintained even battery standby allowing strobes to operate at higher voltage lower current and ensuring a consistent current draw and voltage margin under both primary power and secondary battery standby may include the following Wiring distances up to three times farther than with conventional Support for more appliances for each IDNAC SLC Use of smaller gauge wiring provides installation and maintenance savings with high assurance appliances that operate during normal system testing will operate worst case alarm conditions installation and testing time separate controls on the same two wire SLC installation time and for both retrofit and new construction can be significantly When Class B wiring is used wiring can be T tapped to allow savings in distance wire conduit size and utilization and overall efficiency Use of Self Test and Magnet Test features improve efficiency TrueAlert device reports conveniently identify about each connected appliance Rev 1 7 2019 Notification Appliances Weatherproof Ceiling Mount Multi Candela Horn Strobe Model Series A49AV ES Diagnostics features IDNAC SLCs are in diagnostic mode Self Test and Magnet Test features provide individual appliance testing With the Self Test feature appliance can be confirmed without leaving the control panel Additionally each appliance LED can be selected to pulse when it receives a poll during normal operation details Self Test Mode from the control panel allows on board sensors depending on the device type to detect its own strobe and or horn output then report their status to the control panel Operation is by selected VNAC appliance groups and is either automatic all briefly simultaneously or individually activated by applying a magnet Refer to control panel data sheet for more Self Test information see a list in Table 10 appliance Magnet Test this test mode in response to application of a magnet the appliance LED pulses sequentially to conveniently indicate the appliance address appliance Magnet Test this test mode after the address is indicated by pulsing the appliance LED the strobe will briefly flash and the horn will briefly sound to indicate operation Instrument Two TSIT second generation of the Autocall TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs and IDNet communications before connection to the control panel Please contact your local Autocall representative for additional information addressable wiring isolator Model A4905 9929 Model A4905 9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring to data sheet AC4905 0001 device reports reference 2 Rev 1 7 2019 Notification Appliances Weatherproof Ceiling Mount Multi Candela Horn Strobe Model Series A49AV selection Visual A V Appliances ES Addressable A V Appliance dimensions with cover 8 in H x 7 in W x 3 in D 206 mm x 180 mm x 76 mm color appliance only Select cover and separately instructions 1 Ceiling Mount Audible Visual Only V O Appliances 2 Back boxes 3 S V Covers required when ordering APPLC O models ALARM logo only 4 Wire guards and wire guard back boxes ceiling mount red wire guard ceiling mount red wire guard back box ES A V specifications 5 Environmental specifications application 23 VDC 30 VDC to 151 40 to 66 DC control strobe voltage range temperature rating CD W135 CD W185 CD temperature rating for and uncontrolled wet Public Mode 110 CD temperature rating humidity range The appliance covers and backboxes are available in red and white Do not paint or otherwise alter the factory finishes in way to 120 40 to 49 non condensing at 140 60 for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 to 120 0 to 49 6 Maximum RMS operating current Only AO 3 mA mA mA mA mA mA mA mA mA Rev 1 7 2019 Notification Appliances Weatherproof Ceiling Mount Multi Candela Horn Strobe Model Series A49AV

Related Files