Autocall Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

File Preview
File Preview
Click below to download for free

Text Preview

Automatic Extinguishing Deluge and Preaction Sprinkler System Releasing Control control using the Autocall 4007ES Fire Alarm Control Panel to provide Coverage for multiple areas of Automatic Extinguishing Release and or Deluge and Preaction Sprinkler System Release including audible Control of compatible Listed Approved 24 VDC automatic control actuators Releasing appliance circuits RACs by connecting Notification appliance circuits NACs to Suppression Release Peripherals for actuator Additional actuator circuit control NACs are available using 4009 IDNet Addressable NAC Extenders with Suppression Release Peripherals of events and control Escalation of Events Temporal or 20 bpm march time pattern for first cross zone alarm 120 bpm march time pattern to indicate releasing timer active On steady indicate releasing timer expired and actuator is activated Requires NACs dedicated to conventional horn control not SmartSync operation with strobes controlled on separate NACs IDNet NAC Extenders provide Up to eight NACs for notification requirements and input to suppression release peripherals controlled via IDNet Suppression Release Peripheral SRP with Dual Command Control Dual command control requires IDNet and an activated NAC to initiate release NAC provides wiring supervision to the actuator including monitoring of coil continuity and short circuit supervision to the coil supervision Release Peripheral control features range An on board DC DC regulator compensates for voltage drops to the peripheral and ensures proper control circuit voltage over a wide Provides a single RAC for control of actuators for up to 2 A using a 3 A NAC input 1 A using a 2 A NAC input system components 4007ES Series control panel with Releasing Appliqu Dedicated NAC output from 4007ES or compatible NAC Extender Coil supervision module one per RAC Maintenance Switch one per RAC Abort Switch Listings reference UL 864 Control Units System UOJZ Control Unit Accessories System Fire Alarm UOXX Control Units Releasing Device Service SYZV UL 2017 Emergency Alarm System Control Units CO detection FSZI ULC S559 Central Station Fire Alarm System Units DAYRC ULC S527 Control Units System Fire Alarm UOJZC Control Unit Accessories System Fire Alarm UOXXC Control Units Releasing Device SYZVC Rev 6 Extinguishing Deluge and Preaction Sprinkler System Releasing Control 1 Series Releasing Control Typical Block Diagram combined with Suppression Release Peripherals the 4007ES series fire alarm control panel provides actuator supervision and control for in automatic extinguishing and deluge or preaction releasing systems Hazard area initiating and notification devices are controlled using either or addressable circuits per standard 4007ES capabilities The necessary releasing system logic is implemented within the 4007ES control as required for the local application Extinguishing Release Systems systems automatically activate electrically controlled actuators for the release of a fire extinguishing agent such as dry chemical water spray CO2 or clean agent in response to fire detection device inputs as determined by programming of the host fire alarm control panel Extinguishing Release System Panels are required to have a minimum of 24 hours of standby power Initiating devices must be Listed for the application and may be wired either Class A or B Control actuators must be electrically compatible with the control panel circuits power supplies and are wired Class B to provide coil supervision or Preaction Sprinkler Systems systems automatically activate water control actuators in response to fire detection device inputs 2 Rev 6 Extinguishing Deluge and Preaction Sprinkler System Releasing Control Sprinkler Systems employ open sprinkler heads and provide water flow when the fire detection system activates a common automatic water actuator They are used to deliver water simultaneously through all of the system sprinkler heads This type of system is applicable where the application of large quantities of water over large areas is the proper fire response Sprinkler Systems are similar to deluge systems except that normally closed sprinkler heads are used and supervisory air pressure is in the pipe Operation requires both an activated sprinkler head and an activated fire alarm initiating device with specific programming at the host fire alarm control panel System Requirements Releasing actuators are controlled from a Suppression Release Peripheral A4090 9005 or A4090 9006 Connections are 2 wire Class B circuits with only one 24 VDC actuator per circuit Where applicable two 12 VDC actuators in series or one 12 VDC actuator manufacturer supplied resistor may be used refer to the actuator manufacturer installation documentation for additional details and Coil Supervision Module A2081 9046 must be wired electrically before the actuator and located in the actuator wiring junction box The RAC provides continuity supervision of the actuator coil and wiring and provides short circuit supervision to the coil supervision Cross zoning or other alarm initiation logic per system requirements is to be implemented by programming at the fire alarm control UL Listed Automatic Extinguishing Releasing operation requires that battery standby must be a minimum of 24 hours with 5 minutes alarm and that listed actuators are used refer to Suppression Release Peripheral Wiring Reference FM Approved Automatic Extinguishing Release requires secondary standby to be a minimum of 24 hours with 5 minutes of alarm must be electrically compatible FM Approved Deluge and Preaction Sprinkler operation requires that initiating device circuits be Class A and wired to Listed Approved standby power capacity must be a minimum of 90 hours with 10 minutes of alarm and that compatible Automatic Water Control must be used Refer to actuator list in the Specifications section Maintenance Switches one per RAC are required per NFPA 72 the National Fire Alarm and Signaling Code to allow the system to be or serviced without actuating the fire suppression systems Their use may not be allowed in some jurisdictions always confirm local When used Autocall Maintenance Switches are required to ensure that operation initiates a supervisory condition Abort Switches are available when abort operation is required When used connect to an addressable Supervised IAM model A4090 9001 similar addressable adapter module The Autocall abort switch and the IAM mount in a single gang box 2 1 2 minimum depth Addressable Manual Releasing Stations are used to initiate activation of the releasing actuators with the appropriate time delay by the fire alarm control panel Notification Requirements Each hazard area typically requires general audible and visible fire alarm notification and additional dedicated for area releasing status notification Suppression releasing is compatible with conventional panel mounted NACs as well as for use the 4009 IDNet NAC Extender Additional Suppression Release Peripheral Reference Refer to Installation Instructions 579 385AC Releasing Systems Reference additional information refer to Factory Mutual Research Corporation FMRC FMRC Approval Guide FM Approval standard Automatic Releases Preaction and Deluge Sprinkler Systems note that proper operation of releasing control systems requires that the system design installation and maintenance be performed correctly in accordance with all applicable local and national codes and equipment manufacturer instructions No liability for total system operation is or implied Selection 1 4007ES Releasing Control System Modules Supervision Module Series Switches Refer to data sheet AC2080 0010 for Abort and Maintenance switch details mount mount Switch one per RAC mounts in the releasing actuator wiring junction box see section for details per RAC flush or surface mount indicator lamp models require separate 24 wiring required connects via an IDNet addressable interface module mounted on a gang stainless steel plate installation requires a single gang box 2 1 2 64 minimum depth 2 Releasing Appliqu Required for 4007ES Suppression Releasing Applications Releasing Appliqu field applied 3 Rev 6 Extinguishing Deluge and Preaction Sprinkler System Releasing Control 3 Suppression Release Per

Related Files