Autocall Non-Coded Manual Stations A2099 Series Single Action Operation

File Preview
File Preview
Click below to download for free

Text Preview

Multi Application Peripherals and Accessories Manual Stations A2099 Series Single Action Operation listed Single action models Institutional option Key operated only Pull lever protrudes when alarmed Tamper resistant reset key lock keyed same as fire alarm cabinet Pre signal and annunciator contact options Surface or semi flush mounting Flush mounting option Two stage alarm English French or Bilingual Action Stations require a firm downward pull to activate the switch Completing the action breaks an internal plastic break rod below the pull lever The pull lever latches into the alarm position remains extended out of the cover to provide a visible indication of station was alarmed Stations are designed to activate by key operation This allows access for manual alarms to be limited to authorized Operation requires key insertion and opening of the station option activates when the lever is pulled General alarm requires a key to activate a keyswitch located behind the pull Reset requires use of a key to reset the pull station lever and the alarm switch If the break rod is used it must be replaced requires physical activation of the pull lever except for stations 1 action station 2 action station with institutional cover Additional listings may be applicable contact your local product supplier for the latest status Lexan is a registered trademark of General Electric Co Rev 2 02 2021 Manual Stations A2099 Series Single Action Operation to the National Building Code a manual pull station shall be installed in every floor area near every required exit CAN ULC S524 M91 states stations be mounted not less than 1200 mm nor more than 1400 mm above the floor level In addition the National Fire Protection NFPA gives specific minimum requirements on this subject When manual station coverage appears limited in any way additional units be installed Stations should be mounted with the bottom of the station not less than 1.07 m 3.5 ft or more than 1.52 m 5 ft from the Usually stations are mounted at the 1.37 m 4.5 ft level In order to make buildings and facilities accessible to and usable by the physically some specifications may require that the station be installed not more than 1.07 m 3.5 ft from the floor should be located in the normal path of exit and distributed in the protected area so that they are unobstructed and readily accessible should be provided on each floor to obtain a travel distance not more than 61 m 200 ft to the nearest station from any point in the building station should be provided for each floor where the maximum floor area is 930 m 10,000 ft or more Covers and pull levers are constructed of chip resistant and dirt resistant high impact Lexan polycarbonate Covers are red with white and pull levers are white with red lettering 2099 9819 Black and 2099 9820 Beige are optional adapter kits designed to flush mount any one of the A2099 series stations manual station specification chart action models 1 Single action model specifications Annun key Normally Open Contact N C Normally Closed Contact 2 Accessories gang box depth in 1.5 3.0 breakglass standard English break rod adapter kit black refer Figure 5 adapter kit beige refer to Figure 5 retaining clip for breakglass cover kit surface mount box sheet metal 5.1875 in H x 4 in W x 2.1875 in D 127 mm x 102 mm x 56 mm cast aluminum surface mount box 5 in H x 3.875 in W x 2.1875 in D 127 mm x 98 mm x 56 mm surface mount box sheet metal 5.1875 in H x 4 in W x 2.6875 in D 127 mm x 102 mm x 68 mm key for manual station reset 2 Rev 2 02 2021 information to installation instructions PER 21 502CAN for additional information Manual Stations A2099 Series Single Action Operation or 2975 9178 box 3 mounting Refer to selection chart for requirements 4 MOUNTING 4 BOX 3 Rev 2 02 2021 Manual Stations A2099 Series Single Action Operation adapter kit 2099 9819 beige adapter kit 2099 9820 5 MOUNTING REFERENCE INFORMATION 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 2 02 2021

Related Files