Autocall SmartSync 2-Wire Operation, Non-Addressable Multi-Tone Horns

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM Notification Appliances 2 Wire Operation Non Addressable Multi Tone Horns current 24 VDC Autocall SmartSync operation electronic horns provide Per appliance tone selection of Horn Bell 500 Hz Horn Canadian Slow Whoop Siren or Hi Lo selected using an on board DIP Note 500Hz horn tone is not compliant with NFPA 72 Low Frequency Requirements for Sleeping Areas Output level selectable as standard or high Rugged high impact flame retardant thermoplastic housings available red with white lettering or white with red lettering Diode polarized input for connection to reverse polarity supervised control Notification Appliance Circuits NACs two wire control of audible and visible notification provides Control of horn and bell tones as Temporal Pattern March Time or on continuously controlled separately from visible on the same circuit Slow Whoop Siren and Hi Lo tone selections sound their tones synchronized to each other when receiving SmartSync commands SmartSync March Time pattern produces a 60 BPM output for the 500 Hz Horn and the Bell tone Visible appliances on the same circuit operate at a synchronized 1 Hz Refer to page 2 for SmartSync control list and additional operation notification appliance design provides flexible easy convenient semi flush or surface wall mounting Easily mounts to single gang double gang or 4 inch square electrical In out wiring terminals 18 AWG to 12 AWG Rear of housing does not extend into box accessories Mounting adapters to cover surface mounted electrical boxes and to to Autocall 2975 9145 boxes UL listed wire guard UL ULC listed sound damper for locations requiring attenuation of 5 to dBA stairwells small rooms highly reverberant areas etc Covers are available separately to change color or for replacement reference UL listed to Standard 464 ULC listed to Standard S525 rate 1 Multi Tone Horns are Available as with Red Lettering or Red with White Lettering non addressable multi tone horns provide a flexible of output tones for fire alarm audible notification Tone and output level is set per appliance allowing notification to be tailored to specific area requirements See Table 5 Tone Selection DIP Switch selection determines the local tone A separate DIP Switch position allows selection of a standard or high output sound level selectable appropriate to the location See 5 mounting Multi tone horns can be semi flush or surface on a standard single gang double gang or 4 square 102 mm box Optional accessories are available to increase mounting application flexibility two wire control operation mode allows a two wire circuit to provide the ability activate both the horn and strobe on the same NAC and then allow horn to be silenced while the strobe remains flashing The horn as while the strobe operation is control sources two wire control is available from 4006 4007ES Hybrid 4010ES 4100ES and 4100U Fire Alarm Control refer to individual product data sheets for more information 4009 IDNet NAC Extenders SmartSync Control Module SCM Model A4905 9938 This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7125 2269 0524 7125 2269 0525 and 7135 0026 0334 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local supplier for the latest status Rev 5 2 2020 2 Wire Operation Non Addressable Multi Tone Horns selection 1 Sound damper and adapters Sound Damper package of 20 field installed adhesive backed output attenuator reduces output 5 to 6 dBA After Sound Damper installation measure sound level to ensure with applicable code requirements mount red adapter skirt mount white adapter skirt to cover 1 1 2 in deep surface boxes Plate red for mounting to Autocall2975 9145 box typically for may be mounted vertical or horizontal mounting box requires Adapter Plate A4905 9931 3 8 in H x 5 in W x 1 5 8 in D mm x 133 mm x 41 mm Total with horn 3 1 8 in 79 mm 3 8 in H x 5 in W x 1 5 8 in D mm x 133 mm x 41 mm Total with horn 3 1 8 in 79 mm 5 in x 5 3 4 in x 0.060 in Thick mm x 146 mm x 1.5 mm 7 8 in x 5 1 8 in x 2 3 4 in D 200 x 130 mm x 70 mm Control Module Class A or Class B installs in 4 in square box 2 Synchronization control module in x 4 1 8 in x 1 1 4 in D 102 mm x 105 mm x 32 horn cover with white lettering horn cover with red lettering wire guard with mounting plate compatible with semi flush or surface boxes 1 8 in H x 5 in W x 1 1 2 in D 130 mm x 127 x 38 mm 1 in H x 6 1 in W x 3 1 8 in D 154 mm 154 mm x 79 mm 3 Covers and guard UL listed by Space Age Electronics Inc horn specifications Voltage Range Current Range Range Hz Horn1 Whoop 4 Multi tone horn specifications VDC to 33 VDC mA to 122 0 to 50 to 93 non condensing 100 38 blocks for 18 AWG to 12 AWG 0.82 mm2 to 3.31 mm2 two wires each terminal for in out wiring 5 Multi tone horn sound output characteristics see notes as indicated output ratings per UL 464 chamber test 10 ft 3 output High output dBA dBA output ratings per ULC S525 chamber test 3 m 10 ft output High output dBA dBA to 3700 Hz sweep modulated at Hz rate dBA Hz modulated at 7 ms intervals dBA Hz tone Hz to 1200 Hz sweep dBA Hz to 1200 Hz 1 sec on then repeat 67 dBA tones of 1000 Hz and 800 dBA 250 ms duration dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA dBA Dispersion per ULC S525 testing dBA at 30 off axis dBA at 50 off axis UL output ratings below 75 dBA are for NFPA 72 Private Mode applications ULC output ratings below 85 dBA are for use in applications per local codes Horn Bell and 500 Hz Horn are controlled by SmartSync commands to produce Temporal Pattern March Time Pattern or Continuous Note 500Hz tone is not compliant with NFPA 72 Low Frequency Signal Requirements for Sleeping Areas Horn 500 Hz Horn and Bell provide a 60 BPM March Time Pattern when receiving the SmartSync March Time command Slow Whoop Siren and High Low tones are for use with SmartSync Continuous commands As with the horn and bell tones they are to the controlling SmartSync timing commands allowing synchronization across multiple NACs 2 Rev 5 2 2020 references 2 Wire Operation Non Addressable Multi Tone Horns 2 Adapter plate installation information A4905 9931 A4905 9961 2975 9145 A4905 9931 3 Rev 5 2 2020 2 Wire Operation Non Addressable Multi Tone Horns A4905 9838 A4905 9961 Red skirt A4905 9937 white skirt A4905 9940 3 or semi flush multi tone horn mounting 2020 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice listings may be applicable contact your local Autocall product supplier for the latest status Listings and approvals under Tyco Fire Security GmbH and the names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are registered of the National Fire Protection Association NFPA Rev 5 2 2020

Related Files