Autocall TrueAlarm Photoelectric Smoke Detectors for Two-Wire and Four-Wire Bases

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Smoke Detectors Photoelectric Smoke Detectors for Two Wire and Four Wire Bases ULC CSFM Listed FM Current Current 2 Wire Current 4 Wire Relay Ratings Velocity Range Listed Temp Range Temp Range Temp Range Range 1 Specifications to 32 VDC from Fire Alarm Control IDC 24 VDC to 86 mA maximum exact current is by alarm current limiting of IDC mA typical 24 VDC to page 2 under Product Selection ft min 0 610 m min to 100 F 0 to 38 C to 122 F 9 to 50 C to 140 F 18 C to 60 C to 95 RH from 32 to 122 F 0 to C non condensing White Dia x 1 7 8 H mounted in base mm x 48 mm Smoke Detector Features Data Evaluation Conventional smoke detectors will drift toward being too sensitive due to the accumulation of dust dirt With TrueAlarm analog detection data from the photoelectric is monitored and analyzed at the detector to provide a shifting reference point Compensation The data evaluation and its shifting reference provide a software filtering process that compensates for factors dust dirt etc and component aging establishing accurate reference for evaluating new activity With this filtering resulting drift compensation provides a significant reduction in the of false or nuisance alarms caused by shifts in sensitivity up or down Test Information Status information is available by the magnetic test and observing the detector LED pulses LED will normally go directly into alarm with the magnetic test there is an off normal condition the LED pulses first to indicate condition and then goes into alarm See Detector Status LED Reference Locations Locations should be determined only after careful of the physical layout and contents of the area to be Refer to NFPA 72 the National Fire Alarm Code On smooth smoke detector spacing of 30 ft 9.1 m may be used as a guide detailed installation information refer to A4098 Detectors Sensors Bases Application Manual 574 709AC Selection The A4098 9601 standard sensitivity detector recommended for most applications When a special application for reduced sensitivity detector is required the A4098 9605 should be Consult your local Autocall product supplier for assistance in the proper selection 1 TrueAlarm Detector Mounted in Base smoke detector with on board TrueAlarm drift compensation chamber enclosure Louvered design enhances smoke capture by directing flow to Entrance areas are minimally visible when ceiling mounted Operation is for ceiling or wall mounting indicator LED indicates normal and alarm operated functional test Initiates alarm and verifies performance Identifies general sensitivity status using detector LED available in two sensitivity settings A4098 9601 Standard Sensitivity nominal 2.8 ft obscuration A4098 9605 Special Application Sensitivity nominal 3.5 ft options Bases for 2 wire or 4 wire operation Auxiliary alarm relay output Remote alarm indicating LED for EMI compatibility listed to Standard 268 TrueAlarm photoelectric detectors provide many of the proven analog sensing features for applications where detectors connected to conventional 2 wire or 4 wire initiating device circuits Each TrueAlarm detector has an on board microprocessor that its photoelectric light scattering chamber activity and makes intelligent decision based on light obscuration history as to whether alarm condition is present detectors are packaged in a patented housing that minimizes visibility of the air intake louvers from the normal viewing locations maintaining a high performance smoke capture ability Bases are for remote alarm LED indicator connections and auxiliary relay This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7272 2269 0510 7300 2269 0508 and 7300 2269 0550 for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local supplier for the latest status Rev 9 03 2021 Photoelectric Smoke Detectors for Two Wire and Four Wire Bases Selection Sensitivity standard special application sensitivity not listed Base with connections for Remote LED Indicator Base with Auxiliary Alarm Relay and connections for Remote LED Indicator external 24 VDC for operation Base with Auxiliary Alarm Relay connections for Remote LED Indicator be connected as the only device on IDC to ensure relay operation Plate LED Indicator 2 Smoke Detectors Photoelectric Detector with bases A4098 9788 and A4098 9683 3 Compatible Bases and LED connections are screw terminals for in out wiring 18 to 14 AWG Ratings Single Form C For Suppressed Loads limited 3 A 28 VDC Non power limited 3 A 120 VAC Connections In Out where required contacts and IDC wiring color coded 18 AWG leads LED wiring screw terminals for to 14 AWG Ratings Dual Form C For Suppressed Loads limited 1 A 28 VDC Non power limited 1 2 A 120 VAC Connections In Out where required contacts and IDC color coded 18 AWG leads IDC and LED wiring screw for 18 to 14 AWG 4 Detector Accessories for mounting to surface mounted 4 102 mm square or 4 octagonal boxes to 4 square flush mounted boxes be used when retrofitting existing bases with detector bases A4098 9788 9682 9683 on single gang stainless steel plate 2 1 2 x 1 1 2 x 1 64 x 38 mm x 25.4 mm on single gang stainless steel for 4 wire circuits using A4098 9682 one per circuit select mounting type as wiring is color coded 18 AWG wire Refer to Dimensions and Reference Information for dimensions and additional mounting details 18 AWG 0.82 mm2 14 AWG 2.08 mm2 Mounted VDC End of Line Status LED Indications Indication approximately every 4 seconds On 5 LED Response to Magnetic Test Indication turns ON pulses quickly 6 times in 3 then turns ON pulses slowly 4 times in 8 then turns ON By is initiated is initiated is initiated not initiate Alarm sensitivity is within compensation sensitive out of normal range sensitive out of normal compensation is malfunctioning or other service is is required Testing requires placing a magnet at the designated location on the detector cover for 4 seconds Refer to Application Manual 574 709AC for further and maintenance information 2 Rev 9 03 2021 and Reference Information Photoelectric Smoke Detectors for Two Wire and Four Wire Bases 2 9605 Dimensions Mounted on Base 3 Remote LED Indicator not to scale 3 Rev 9 03 2021 Information Electrical boxes are supplied by others Photoelectric Smoke Detectors for Two Wire and Four Wire Bases 4 Information 4 shows 4098 9832 adapter plate required for mounting to surface mounted boxes and to 4 square flush mount boxes A4098 9682 and A4098 9683 include a relay module that mounts in base electrical box smoke detector bases A4098 9788 A4098 9682 and A4098 9683 Box Requirements Without relay base A4098 9788 4 octagonal or 4 square 1 1 2 deep Single gang 2 deep With relay bases A4098 9682 and A4098 9683 4 octagonal 1 1 2 deep with 1 1 2 extension ring 4 square 1 1 2 deep with 1 1 2 extension 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without notice

Related Files