Cerberus Pyrotronics RLP-4 8 12 Remote Lamp Panel 8012

File Preview
File Preview
Click below to download for free

Text Preview

Remote Lamp Panels AND ARCHITECT SPECIFICATIONS RLP 4 RLP 8 RLP 12 Listed Cerberus Pyrotronics Remote Lamp Panels RLP 4 and RLP 12 are designed for use with all Cerberus systems where remote lamp annunciation of detection system activity is desired This activity could DI 3 type detector operation using a 24V lamp directly using dry contacts one may indicate zone alarm alarm trouble power failure etc RLP panels are normally fitted with neon lamps to the high voltage detector pulse lamp operation 6 volt 24 volt 48 volt and 120 volt lamps are as optional items to match the electrical charac of any desired system RLP 4 remote lamp panel is equipped with 4 lamps clear lenses and is designed for 2 gang switch mounting The RLP 8 has 8 lamps and requires 4 switch box mounting while the RLP 12 has 12 lamps requires 6 gang switch box mounting The panels are attractive whether mounted vertically or horizon panel has an upper and lower bracket to accommo plastic or nameplate strips for lamp identification Data RLP panel is completely assembled with screw type on its printed wiring board to facilitate wiring The panel is then connected to the switch with upper and lower fastening screws The plate screws are in such a position that they are by the nameplate strip after installation and Architect Specifications remote lamp panel for the Cerberus Pyrotronics shall be Cerberus Pyrotronics RLP insert 4 8 12 The panel shall be capable of monitoring the of the Cerberus Pyrotronics DI 3 type detector 24V lamp directly or using dry contacts one may zone alarm system alarm trouble power failure The RLP panel shall be Underwriters Laboratories Inc NUMBER in conduit or 18 AWG limited energy shielded without conduit if permitted by local building codes wiring shall be performed as indicated in drawings supplied by Cerberus Pyrotronics electrical contractor shall mount the RLP 4 panel on a deep switch box the RLP 8 panel on a 4 gang switch box and the RLP 12 on a 6 gang deep box The wiring between the panel and the system shall be 18 AWG thermoplastic fixture wire Information No Lamp Panel 4 position Lamp Panel 8 position Lamp Panel 12 position Lamps order total quantity needed lb lb lb No lamp lamp lamp lamp lamp Pyrotronics Ridgedale Ave Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1995 sheet dated 3 94

Related Files