Cerberus Pyrotronics ZC-30 31 Control Module Zone Coder 3172

File Preview
File Preview
Click below to download for free

Text Preview

System 3 Control Module Zone Coder AND ARCHITECT SPECIFICATIONS ZC 30 ZC 31 110 Code Capacity Positive Non Interfering Coding Microprocessor Logic Placement Supervised Each Code Field Programmable One to Four Digits per Round to Fourteen Pulses per Digit ULC Listed NYMEA FM and City of Chicago Cerberus Pyrotronics ZC 30 and ZC 31 are zone modules designed for use with Cerberus Pyrotronics 3 Control Panels Zone Coders are required when alarm system requires an audible coded alarm signal one or more zones to facilitate fire location ZC 30 Zone Coder module is a microprocessor based module designed to output a pre programmed sequence when activated by a System 3 Zone Each zone or group of zones which requires a coded output signal has its zone output signal s fed an input terminal of the zone coder Associated with two input terminals is a ZC BD Dual Code Board boards are programmed with the code information for their respective zones The ZC 30 will accept to five ZC BD for a capacity of ten individual codes Zone Coder Extender modules are available to the capacity of the basic zone coder module Each will accept ten ZC BD which will generate 20 codes Up to five ZC 31 Extenders may be to a ZC 30 for a total capacity of 110 unique input terminals are continuously scanned for an alarm from a zone module When an alarmed zone is the information programmed on the respective ZC Dual Code Board is read into the microprocessor The then processes this information and outputs the NUMBER code in a form compatible with System 3 output If the alarm inputs occur faster than the codes transmitted they are stored by the microprocessor When the first code has completed the required of rounds the microprocessor will transmit the priority code in its memory Priority is determined physical terminal location on the ZC 30 and ZC 31 No 1 has the highest priority while terminal No has the lowest code may contain from one to four digits as re Each digit may consist of from one to fourteen The system may be programmed to sound from to four rounds All code information for a given zone be programmed or changed in the field if required consists of removing selected diodes on the No special equipment is required The system rate is adjustable from 1.6 to 3.8 pulses per second two pulses per second the standard factory setting coder output may be set to either remain energized or after the completion of the code rounds ZC 30 Zone Coder module and the ZC 31 Zone Coder module each require four module spaces in the 3 enclosure The ZC BD Dual Code Boards plug the ZC 30 and ZC 31 and require no space in the The ZC 30 derives its power from the System 3 conductor bus Connections between the ZC 30 and ZC 31 Extenders are made with the supplied ribbon The ZC 30 is placement supervised Any failure of ZC 30 software or internal power supply will generate a trouble and light a yellow LED on the ZC 30 and Architect Specifications system shall be provided with a UL listed solid state coder Activation of any zone shall automatically rounds of the respective code on all audible Alarms shall sound in a positive non interfering Wiring successive fashion so as to sound all codes without zone coder shall be of totally solid state design the need for motors or code wheels The system be programmable in the field as to the number of it sounds Each code shall contain from one to four with from one to fourteen pulses per digit all field The coder shall be expandable in the field accommodate up to 110 different codes The coder be programmable for either continuous after ring or at the end of the coding time coder shall transmit its codes on a priority basis with highest priority codes being transmitted first All codes sound in positive successive fashion without inter from subsequently received codes The coder be compatible with the subsequent alarm feature of control panel Failure of the coder software or internal supply shall generate a system trouble The zone shall be a Cerberus Pyrotronics Model ZC 30 ZC 31 Information or MA 10 MA 1 MA Information Coder Module MA 10 MA 1 MA lb 90 kg Coder Extender Module lb 90 kg Code Boards lb 23 kg Pyrotronics Ridgedale Avenue Knolls NJ 07927 201 267 1300 201 397 7008 in U S A Pyrotronics East Pearce Street Hill Ontario 1B7 CN 905 764 8384 905 731 9182 1995 sheet dated 8 94

Related Files