Cornell Communications Door Monitor Wiring and Operating Overview A-1000

File Preview
File Preview
Click below to download for free

Text Preview

A 1000 SERIES DOOR MONITOR AND WIRING INSTRUCTIONS SYSTEM OPERATION zone switch contains a red and a green LED Each time the zone switch is pressed the zone status toggles between and disarmed green LED indicates the disarmed status The associated door may be opened without causing an alarm A short open in the door contact wiring will cause the panel to go into the alarm condition steady red LED indicates the armed status If an armed door is opened the alarm condition occurs The re d LED will and an intermittent audio tone will sound Pressing the cancel tone switch on the master panel will silence the audio but will not clear the alarm If another zone should go into the alarm condition the tone would again sound until t he tone switch is pressed or until all alarms are canceled cancel an alarm simply press and release the zone switch This will return the zone to the disarmed status and cancel the alarm SUPPLY REQUIREMENT A 1000 Series Door Monitor System is designed to operate on regulated 12VDC power Connecting an AC power or a DC power supply with a voltage above 12V will damage the system Make sure you are using one of the CORNELL power supplies P 512241A P 512243A or the B 5243A Use minimum 18 gauge 2 conductor from power supply to the Master Panel The B 5243A power supply provides battery back up allowing a typical to operate 24 hours or more on back up power wiring to be minimum 22 gauge unless otherwise specified Refer to drawing D1000W A for basic system wiring FEATURES alarm volume Volume of intermittent tone is adjustable with a screwdriver from the front of the panel Door contacts The system can use either normally open N O or normally closed N C contacts Two 22 wires required between door switch and zone card Refer the drawing D1000W A output per zone Each zone card has a switched negative open collector transistor output at 9 which turns on whenever that zone is in the alarm condition Rating 500mA 40VDC output system The terminal on the tone board is a switched negative open collector output which turns on whenever any zone is in the alarm condition Automatically turns off when all are canceled Rating 100mA 12VDC Door Status Output Each zone card has a door status output at terminal 11 switched negative open collector that turns on whenever the door is open regardless of armed disarmed status Rating 100mA 12VDC Switch Disable Cutting the factory installed Zone Switch Enable jumper between terminals 1 and 3 of a card will disable the zone switch from making changes in the armed disarmed status of the door Status will then only be possible using a remote zone control product see OPTIONS REMOTE ZONE PRODUCTS Switch Disable during alarm Cutting jumper J1 on a zone card will disable the zone switch from making in the armed disarmed status of the door only when the zone is in the alarm condition The zone switch still function while the zone is either disarmed or armed Once in the alarm condition clearing the alar m will be possible from a remote zone control product Note If the Zone Switch Enable jumper see Zone Switch is cut the zone switch will be disabled under all conditions ZONE MONITOR CONTROL PRODUCTS The Remote Control Panel duplicates the functions of the Master Panel except it has a high low switch instead a Tone switch for control of the alarm tone When the Master Panel tone is silenced the tone for the Remote Panel is also silenced Individual zones have one green LED one red LED and a momentary three position neutral toggle switch Activating the toggle switch to the left or right will disarm or arm the zone respectively than one A 1600 panel may be used Two 18 gauge conductors one 22 gauge conductor plus four 22 gauge conductors per zone all to master panel to drawing DA1600WM The Remote Monitor Panel provides a visual and audible indication of any or all zones Each zone contains green LED and one red LED The panel contains a tone hi low switch to control the audible alarm tone volume the Master Panel tone is silenced the tone at the A 1700 panel is also silenced More than one A 1700 panel may used Two 22 gauge conductors one 22 conductor plus two 22 gauge conductors per zone all to master panel Refer drawing DA1600WM Remote control station for a single zone comprised of one green LED one red LED a key switch and a toggle on a single gang stainless steel plate The key switch will enable disable the use of the toggle switch When the toggle switch will change the status of that zone Requires 5 conductor 22 gauge cable to Master Panel Refer to drawing DA1800WM A key operated switch with built in timer designed to permit authorized personnel to pass though the door the zone is armed The A 1801 has a key switch and red LED mounted on a single gang stainless steel plate The LED will glow when the zone is armed The red LED will flash when the zone is in the alarm condition Operating key switch will disarm the zone and start the timer allowing the user to pass through the door After the user time period 1 second to one minute approximately that zone will automatically re arm itself Requires 5 conductor 22 gauge cable from switch to Master Panel Refer to drawing DA1800WM A key switch and a red LED on a single gang stainless steel plate It is designed to b e used in conjunction with A 1801 A typical application would consist of an A 1802 installed on the outside of a secured door allowing entry the building when the zone is armed Operating the key switch starts the timer in the A 1801 disarming the door the delay period of the A 1801 timer the zone will automatically re arm itself The red LED will glow when the is armed and will flash when the zone is in the alarm condition Requires four 22 gauge conductors to A 1801 Refer to drawing DA1800WM A keypad station with arm disarm exit delay feature The exit delay feature will disarm the zone for a user period of 10 60 seconds allowing passage though an armed door At the end of the delay period the zo ne automatically re arm itself The A 1806D contains a 12 key keypad a red LED a green LED and a yellow LED on a stainless steel plate The green LED glows when the zone is disarmed The red LED glows when the zone is and flashes when the zone is in the alarm condition The yellow LED glows during the exit delay period Requires six 22 gauge conductors to Master Panel Refer the drawing DA1806WM A keypad station with the exit delay feature The zone cannot be armed or disarmed using the A 1808D Requires six 22 gauge conductors to Master Panel Refer to drawing DA1806WM and A 1901 Disable switch Master Panel Option to disable individual zone switches at the Master Panel may be mounted on the Master Panel or at a remote location on single gang stainless steel plate A 1900 Use 2 conductor cable from switch location to pins 1 and 3 on terminal edge connector as shown Jumper from 1 to pin 3 must be removed The disable feature can be wired to selected zones Refer to drawing DA1900WM

Related Files