DSC FSA-210 - installation manual - English

File Preview
File Preview
Click below to download for free

File Data

Name dsc-fsa-210-installation-manual-english-2374960815.pdf
Type PDF
Size 1.06 MB
Downloads

Text Preview

FSA 210 Series Smoke Detector and Operating Instructions this instruction sheet thoroughly before installation and use of the 2 Wire Smoke Detector This instruction sheet is intended to be used the Installation Manual of the alarm control panel All the instructions spec within that manual must be observed Test Button magnet here Siren P A A I I N N T T N N O O T T Marks FSA 210 is a 2 wire photoelectric smoke detector with the available options fixed temperature and rate of rise detector internal piezoelectric alarm auxiliary form C and or remote LED output Three versions are available version UL Canadian version ULC and an International EU Heat detection based on rate of rise has not been by UL ULC every 7 to 8 seconds the unit tests for a smoke heat alarm condition During this sequence the unit also self diagnostics and checks for faults During normal the LED will flash every 50 seconds and the siren will sound Alarm smoke detector has a nominal fixed alarm sensitivity refer the Specifications on the last page and it will go into alarm Instructions Smoke Detector Placement smooth ceilings detectors be spaced 9.1M 30 feet as a guide Other spacing be required depending on height air movement the of joists uninsulated etc Consult National Fire Code NFPA 72 Chapter 11 national standards for recommendations the signal level exceeds the alarm threshold and send alarm signal to the control panel During an alarm the LED flash once per second and the siren will sound the evacua temporal pattern UL EU or continuous beeps ULC Alarm Interconnection detectors with sirens can be connected using the Polarity Reversal Module When a fire alarm occurs panel will signal the PRM 2W to reverse the polarity of the loop This will activate the sirens of all units connected the loop Refer to the PRM 2W 4W Installation Instructions installation details Drift Compensation detector automatically compensates for long term envi induced changes to maintain a constant smoke When the drift compensation has reached its high low limit of adjustment the detector will go into the trou state Alarm heat detector will go into alarm when the heat signal level the heat alarm threshold 135 and send the signal to the control panel The detector will also go into alarm if there is a rapid increase in the temperature over a period of time During an alarm the LED will flash once second and the siren will sound the evacuation temporal UL EU or continuous beeps ULC Indications Sensitivity Production Range Flash 1 50s 1 1s Smoke Heat or or 1 1s 1 50s Temporal or 1 50s Deactivated 1 50s Deactivated or Restore Alarm Power Trouble Trouble Switch Failed Switch Pass 1 1s NOT locate smoke detectors at the top of peaked or ceilings the dead air space in these locations may pre the unit from detecting smoke Avoid areas with turbulent flow near doors fans or windows Rapid air movement the detector may prevent smoke from entering the Do NOT locate detectors in areas of high humidity NOT locate detectors in areas where the temperature rises 38 100 or falls below 5 41 smoke detectors in accordance with NFPA 72 11 detectors shall be installed outside of each area in the immediate vicinity of the bedrooms and each additional story of the family living unit including and excluding crawl spaces and unfinished attics new construction a smoke detector shall also be installed in sleeping room Mount Smoke Detector Backplate backplate using screws pro and the appropriate holes on mounting plate Install wiring in accordance the appropriate national and electrical codes For UL ULC the power supply must supplied from a UL ULC Listed control unit The dust cover protects unit when not in service Remove dust cover before use EU and International versions shall be powered from an to the local authorities alarm controller Wiring to the wiring diagrams in this installation sheet and provided in the Installation Manual of the alarm control being used with the unit Before connecting the unit the wires from the electrical box for connection Do use frayed or bent wire Holes Device NC C Do NOT use looped wire under terminals Break wire run to provide supervision of connections wiring is completed inspect it and correct any errors applying power to the unit When the wiring has been reviewed neatly insert the wires into the electrical and secure the unit to the mounting plate connect this device use only wiring listed as fit for the pur Mounting Installation the detector on to the base using the detector and base plate marks Press the detector in place while rotating the detec clockwise until the detector snaps place Remove the side tab from locking tab to lock in place optional If the side tab is removed to lock the detector tab with a small flat blade screwdriver and rotate counter clockwise until the alignment marks line up detector Test Unit test for units without a siren by placing a magnet near LED Test Button for greater than 5 seconds Initiate test for with a siren by pressing the test button for greater than 5 activation is indicated by the LED the siren and the reporting to the Control Panel If the smoke detectors inter connected using model PRM 2W and a detector is then all detectors will sound The detector restores to when the test button is released or when the magnet removed Allow a minimum of 20 seconds between test activa the detector is in one of the following states when a test is it will not enter an alarm state Compensation trouble Failure of heat or smoke detector Other internal faults that could prevent a smoke or heat Smoke sensitivity of installed detectors can be mea without removal or an alarm being generated using the Smoke Detector Test Meter Unit with FSD 100 Smoke Detector Test Meter test the unit using the FSD 100 set the test meter up to devices as per the instructions supplied with the test Depress the test button or place the FSD 100 on outside edge of the plastics beside the test button to acti the reed switch on units without siren on the smoke for 1 second and release If the test button is held for 5 seconds or longer an will be generated Move the test meter over the center the detector wait until you hear the test meter beep the unit and the information can be immediately Please see the instructions supplied with the FSD Smoke Detector Test Meter for more information the tests one at a time Performing simultaneous tests multiple detectors may trigger an alarm at the control Removing the Chamber for Cleaning clean or replace the smoke chamber the detector must be Press the 3 tabs on the bottom of the detector outward to Remove the bottom portion which contains the PCB and chamber Place thumb and forefinger on the sides of the chamber in locations indicated by the arrows on top of the cham Squeeze gently inward and pull up and the chamber will The removable portion can now be replaced or cleaned can be done using compressed air Do not use a as it may leave particles on the inner wall Replace the new or cleaned chamber by pressing it down it snaps into place Locate and press the backplate the housing making sure the 3 locking tabs are into their locked position Compensation Reset replacement of the smoke sensor or other changes change the background signal noise of the detector this the drift

Related Files