DSC Maxsys4020CFv3

File Preview
File Preview
Click below to download for free

File Data

Name dsc-maxsys4020cfv3-7835624190.pdf
Type PDF
Size 817.15 KB
Downloads

Text Preview

Maxsys n t e g r at e d s Y S T E M S T E C H N O L O G Y TO 128 ZONE FIRE CONTROL PANEL PC4020CF is the UL listed commercial fire version of the PC4020 control panel As such the PC4020CF has the same system and features as the PC4020 plus added features and for commercial fire applications as described herein Panel Fire Features addition to all of the features of the PC4020 see separate spec sheet following are additional hardware and software features of the for use in commercial fire applications PC4020CF control panel is supplied in red system cabinet c w PC4701 fire module 16VAC 40VA transformer PC4701 fire module includes 1 Class two wire smoke detector zone accommodating 12VDC compatible detectors supervised communicator outputs connection for house telephone 1 Class waterflow zone 1 fire alarm actuated relay Form rated 2A 30VDC 1 fire trouble actuated relay Form rated 2A 30VDC up to 112 DSC AMS 220 addressable smoke detectors can be added the system spread over one or both of the addressable loops addressable fire zones may be programmed as the following types standard fire zones delayed fire zones for residential only auto verify fire zones all hardwired zones on the PC4020CF can be programmed as fire with the following zone types standard fire zones auto verify fire zones supervisory zones waterflow zones delayed fire zones for residential only fire drill activates main bell output and PC4702BP fire bell outputs to their programmed fire signalling modes without activating functions and without sending reporting codes to the central Keypads display Fire Drill in Progress during test If an actual occurs during test the test is automatically cancelled and the fire alarm functions occur fire inspector test ensures that all fire initiating devices are and are supervised All test results are logged to system event buffer scheduled smoke detector tests 50 time date smoke detector test programmable by partition for addressable detectors only lamp test use keypad to activate annunciator lights for 2 seconds Expansion addition to all of the modules available for the PC4020 see separate sheet the following are specially designed for use with the in commercial fire applications PC4702BP fire system bell panel provides 2 supervised bell outputs c w battery charger 28VAC 170VA and cabinet with space for two 12volt 4Ah sealed rechargeable batteries PC4204CF fire system quad relay power supply module to PC4204 but c w battery charger 16VAC 40VA transformer cabinet with space for two 12volt 7Ah sealed lead acid batteries PC4612 fire zone annunciator 1 12 zone surface mount keypad plastic annunciator Includes common fire zone trouble fire bell trouble common system trouble and AC indicators system can also include PC4632 and PC4664 thirty two and four zone point graphic annunciators to annunciate fire zones zones and common system indications programmable fire alarm output patterns steady temporal pattern PS4350R fire system external battery charger for longer standby pattern pulsed or strobe fire required by listed fire systems programmable fire bell options bell cut off time and fire silence time all PC4702BP bell outputs are supervised for short circuit open circuit ground fault alarm autoscroll displays fire alarms and selected trouble at 2 second intervals on system LCD keypads displayed include bell zone trouble fire alarm zone label fire bell has been silenced failure to communicate fire alarm zone label supervisory zone label keypads with red bezels for fire application at least one LCD4521 LCD4520 must be used with the PC4020CF keypad piezo buzzer will sound continuously if communication is with control panel LCD4521 same as LCD4501 but with red bezel Five function have fire system specific assignments Silence Trouble Fire Reset Lamp Test Silence Bells Fire Drill LCD4520 same as LCD4500 but with red bezel Panel Electrical Specifications System Arrangement bell output 700mA max continuous for burglary only PTC over current protected self restoring AUX output 12VDC 500mA max SAUX output 12VDC 300mA max SAUX output is normally 12VDC and power is removed upon Typically used to reset 4 wire smoke detectors total for AUX output and SAUX output is 500mA max If the SAUX output is loaded to 200mA then only 300mA for the AUX output AUX and SAUX outputs protected by a common PTC over current which is self restoring PGM outputs as standard PGM outputs 12VDC 50mA max each outputs are normally unpowered and switch to 12VDC activation as addressable outputs 12VDC 170mA max each PGM outputs are individually programmable as addressable or as general purpose PGM outputs Combus 500mA max from the PC4020CF main panel additional power is provided by PC4204CF modules Maximum capacitance is 80nF which is typically 4,000 feet of wire Consult wire Mfg specifications total loading for the Bell output AUX SAUX PGM1 PGM2 the Combus must not exceed 900mA battery charger up to 350mA to charge 12volt lead acid batteries to 14Ah capacity Battery charger is supervised for opens and is by PTC over current device which is self restoring input power 16VAC 40VA ground fault detection built in and enabled by connecting earth to EGND terminal on PC4020CF main panel maximum power from the PC4020CF panel power supply may limited by its ability to maintain the required standby time The external battery charger can be used to assure maximum loading capability and provide the required standby See the Installation Manual for panel loading and standby calculations Specifications operating environment 32 to 122 0 to 50 90 RH non condensing PC4050CR red cabinet surface mount hinged door with screw closure provision for door and wall tamper switches space for one 12volt 7Ah lead acid rechargeable battery 14.8 H x 12.0 W x 4.9 D 37.6 x 30.5 x 12.5cm AC wiring compartment provision for door keylock Smoke Detectors 2 wire smoke detectors DSC MN220 220T DSC AMS 220 220T addressable addressable loops per system T tapped or star using 2 conductor station wire PC4204CF is added when additional power is required to power downstream from PC4204CF up to 16 PC4204CF per system leg up to 305m PC4020CF conductor wire 1 2 see PC4020 spec sheet Information control panel with fire option c w PC4701 fire module PC4050CR red cabinet manual user manual and programming worksheets PC4020CF main control module PT1016 transformer module mounting hardware and 32 EOL resistors as PC4020CF but with attack resistant cabinet are not supplied with the main panel at least one fire keypad red bezel is required per system Select from the following keypads alphanumeric keypad with red bezel without function keys as LCD4520 but with wall tamper switch alphanumeric keypad with red bezel and 5 function keys as LCD4521 but with wall tamper switch LCD4501 T are identical to the above but do not have bezels Control Units System CS A M SS WF Central Station Burglar Alarm Local Burglar Alarm Police Station Burglar Alarm Household Fire Warning Household Burglar Alarm Central Stati

Related Files