Installation Instructions Please refer to the System Installation Manual for information on limitations regarding product and function and information on the limitations as to liability of the manufacturer. LCD5501Z keypad presents system status an LCD-style display along with fixed and numbers. The keypad can be used security systems with up to 32 zones. The is compatible with the following DSC systems: PC580 v2.3 and higher PC1555 v2.3 and higher PC5008 v2.3 and higher PC5010 v2.0 and higher PC5015 v2.2 and higher Connects to control panel via 4-wire Keybus One keypad zone input Current draw: 45mA (standby) Optional tamper version Five programmable function keys Ready (green), Armed (red) and Trouble (yellow) lights LCD5501Z package includes the following One LCD5501Z keypad Four mounting screws One keypad inner door label One set of Fire, Auxiliary and Panic key labels should mount the keypad where it is acces- to designated points of entry and exit. you have selected a dry and secure perform the following steps to mount keypad: Remove the keypad backplate by loosening the located at the base of the unit. Secure the keypad backplate to the wall in the location. Use the screws provided. Before attaching the keypad to its backplate, the keypad wiring as described in the section. 1.0 the Keypad all wiring is complete, you will need to a 2-digit number that tells the system the and slot assignment of the keypad. your system has partitions, you will need to assign the keypad to a partition (1st digit). slot assignment (2nd digit) tells the panel keypad slots are occupied. The panel then generate a fault when a keypad signal is not present. There are available slots for keypads. LCD5501Z are always assigned to slot 1 by You will need to assign each keypad its own slot (1 to 8). the following at each keypad installed on system: Enter Installer Programming by pressing Code] Press [000] for Keypad Programming Press [0] for Partition and Slot Assignment Enter a two digit number to specify the and slot assignment. If your system does not have partitions, [1] for the first digit. digit digit 0 for Global Keypad 1 for Partition 1 Keypad 2 for Partition 2 Keypad 1 to 8 for Slot Press the [#] key twice to exit programming. After assigning all keypads, perform a reset by entering [*][8][Installer The panel will now supervise all keypads and enrolled modules on system. Before beginning to wire the unit, ensure that power (AC transformer and battery) is from the control panel. Connect the four Keybus wires from the control (red, black, yellow and green) to the terminals (R B Y G). Consult the diagram You can connect a device – such as a door – to the terminal of the LCD5501Z. eliminates the need to run wires back to control panel for the device. To connect the run one wire from the device to the Z and the other wire from the device to B (black) terminal. For powered devices, the red wire to the R (positive) terminal and black wire to the B (negative) terminal. When end of line supervision, connect the zone to one of the configurations outlined your system Installation Manual. Power all wiring is complete, apply power to the panel: Connect the battery leads to the battery. Connect the AC transformer. more information on control panel power see the control panel Installation Do not connect the power until all wiring is the Keypad are several programming options avail- for the LCD5501Z keypad. These are below. Record all your programming in the programming worksheets in- in this manual. the LCD5501Z is similar to pro- the rest of the system. When you are the LCD5501Z programming sections, the will display which options are turned on the top of the display. To turn an option