PC4701 Fire Expansion Module Instructions PC4701 is a fire expansion module for use with PC4010CF/ Maxsys security systems. One module may be per system. The PC4701 cannot be used on a Maxsys system if an is also connected. Connects to control panel via 4-wire Combus Current Draw: 40 mA (from Combus) Class B / Style B 2-Wire Smoke Detector Supervision Operating Voltage Range: 8.9-12.0 VDC Maximum Alarm Current: 80mA Maximum Ripple: 0.5 VP-P Compatibility Identifier: FM1 Maximum line resistance: 50W Class B / Style B Waterflow Supervision Supervised Dual Telephone Lines Service Type: Automatic, Manual, Sprinkler Supervisory, the PC4701 Signaling Type: Non-Coded Unpacking PC4701 package includes the following parts: One PC4701 circuit board 2 listed end-of-line resistors (2200 ohms) Four plastic stand-offs Mounting the PC4701 on either side-wall of the PC4010CF/ cabinet, mounted in a dry, secure location. the following steps to mount the unit: Press the four plastic stand-offs through the mounting holes the side wall of the cabinet. Secure the cabinet to the wall in the desired location. Use wall anchors when securing the cabinet to drywall, concrete, brick or other surfaces. Press the circuit board into the plastic stand-offs to secure the to the cabinet. the unit is mounted, complete the wiring. Wiring beginning to wire the unit, ensure that all power (AC and battery) is disconnected from the control panel. the following steps to complete wiring: Connect the four Combus wires to the PC4701. Connect the black, yellow and green Combus wires to the RED, BLK, and GRN terminals, respectively. Complete all other wiring according to the wiring diagrams Fire Trouble Contact the Common Fire Trouble Contact is connected, the output will when any of the following troubles occur: Fire Zone Trouble Any Bell Trouble Any AC Trouble Any Battery Trouble Ground Fault Trouble Communication Troubles output will deactivate when all trouble conditions are Refer to the PC4010/PC4020CF Installation Guide for information on these trouble conditions. Fire Alarm Contact the Common Fire Alarm Contact is connected, the output will when an alarm occurs on any fire zone. The output will when all fire zones have been successfully reset. Line Switching the PC4701 detects a TLM trouble on either telephone line, will automatically use the other telephone line if a needs to be sent. If there are no TLM troubles, PC4701 will use telephone line 1, leaving telephone line 2 for the premises telephones. Applying Power all wiring is completed, apply power to the control panel. the battery leads to the battery, then connect the AC For more information on control panel power see the control panel Installation Manual. Do not connect the power until all wiring is complete. all wiring is complete, the module must be enrolled on the To enroll the module, perform the following: Enter installer programming by pressing [*] [8] [Installer the Module Scroll to Hardware and press the [*] key. Scroll to Module and press the [*] key. Scroll through the different modules until Fire is Press the [*] key. After this is done, the keypad the module number and confirms enrollment (e.g. Fire Mod 01 Enrolled refer to the System Installation Manual for information on limitations regarding product use function and information on the limitations as to liability of the manufacturer. the Module more information regarding module enrollment, see the panel Installation Manual. access PC4010/PC4020 programming, enter [*][8] followed the Installer code. Program the sections indicated on this and record your programming choices in the space The waterflow and 2-wire smoke zones are hard-coded the zone type cannot be changed. Refer to your Commercial I