System Introduction Panel Specifications Zone Configuration: 8 Fully Programmable Zones 37 Access Codes: 32 User, 1 System Master, 2 Partition Master and 2 Duress Expandable to 32 Zones Hardwired expansion available using the PC5108 Eight Zone Expansion Module Wireless expansion available using the PC5132 NB Wireless Zone Expansion Module (up to 32 wireless 418 MHz, Wireless technology, fully supervised). Normally Closed, Single EOL, Double EOL 27 Zone Types, 8 Programmable Zone Options 2 Partitions Alarm Output: Supervised Bell Output (current limited at 3 amps), 12 VDC Steady or Pulsed Output Memory: Will not lose programming or system status on complete AC and Battery failure Outputs: Up to 14 Programmable Voltage Outputs, 14 programmable options One Low Current (50 mA) PGM output on main panel Eight Additional Low Current (50 mA) PGM outputs available using the PC5208 module Four High Current (1 Amp) PGM outputs Available Using the PC5204 module 1 PC5204 Output Fully Supervised for Siren Output 1 Amp Regulated Power Supply: 500 mA Auxiliary Supply, 12 VDC Positive Temperature Coefficient (PTC) components replace fuses Supervision for loss of AC Power, Low Battery Internal Clock Locked to AC Power Frequency Requirements: Transformer = 16.5 VAC, 40VA Battery = 12 volt 4 Ah minimum rechargeable sealed lead acid Keypad Specifications: 4 Different Keypads Available: PC5508 8 Zone LED Keypad PC5532 32 Zone LED Keypad PC5516 16 Zone LED Keypad LCD5500 Alphanumeric Keypad Each Keypad has 5 Fully Programmable Function Keys Connect up to 8 Keypads Four Wire (Quad) Connection to Keybus Built in Piezoelectric Buzzer Communicator Specifications: Supports all Major Formats including Scantronics 4-8-1 slot, SIA and Contact ID Event Initiated Personal Paging 3 Programmable Phone Numbers 2 Account numbers DTMF and Pulse Dialling DPDT Line Seizure Anti-jam Feature Split Reporting of Selected Transmissions to Each Telephone Number Trouble by Zone Telephone Line Trouble Bell Output Trouble AUX Power Supply Fault Failure to Communicate Supervision Features Power832 continuously monitors a number of possible trouble conditions including: AC Power Failure Fire Trouble Low Battery Condition Loss of Internal Clock Tamper by Zone Module Fault (Supervisory or Tamper) Alarm Prevention Features Audible Exit Delay Urgency on Entry Delay Swinger Shutdown Communication Delay Features Keypad Activated Alarm Output and Communicator Test Keypad Lockout Audio Capability using the PC5908 Audio Interface Module which allows local intercom and Central Audible Exit Fault Quick Exit Recent Closing Transmission 2-Way Listen in. All modules connect to the system via a four wire Keybus up to 1000 from main panel Event Buffer can be printed using PC5400 RS232 Serial Interface module Supports the Escort5580 Voice Prompt Module with Automation/Lighting Control 256 Event Buffer, Time and Date Stamped Upload/Download Capability Devices maximum of eight (8) keypads can be connected to the control panel and can be any combination of the listed. Different keypads (with function keys) can be used for different size systems; 8 zone, 16 and 32 zone. zone LED keypad zone LED keypad zone LED keypad keypad Eight Zone Expander Module zone expander module can be used to increase the number of zones on system. Up to 3 modules can be connected to increase the system zones to maximum of 32. NB Wireless Receiver Module PC5132 NB Wireless Receiver module can be used to connect up to 32 devices. All devices are spread spectrum, 418 MHz, fully supe