DSC PC5320 Multiple Wireless Receiver Module

File Preview
File Preview
Click below to download for free

File Data

Name dsc-pc5320-multiple-wireless-receiver-module-0183492765.pdf
Type PDF
Size 770.38 KB
Downloads

Text Preview

FCC COMPLIANCE STATEMENT Changes or modifications not expressly approved by Digital Security Controls Ltd could void your authority use this equipment equipment generates and uses radio frequency energy and if not installed and used properly in strict accordance with manufacturer instructions may cause interference to radio and television reception It has been type tested and found comply with the limits for Class B device in accordance with the specifications in Subpart of Part 15 of FCC Rules are designed to provide reasonable protection against such interference in any residential installation However is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to or radio reception which can be determined by turning the equipment off and on the user is encouraged to try to the interference by one or more of the following measures Re orient the receiving antenna Relocate the alarm control with respect to the receiver Move the alarm control away from the receiver Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits necessary the user should consult the dealer or an experienced radio television technician for additional suggestions user may find the following booklet prepared by the FCC helpful to Identify and Resolve Radio Television Problems This booklet is available from the U S Government Printing Office Washington D C 20402 004 000 00345 4 Warranty warrants that for a period of one year from the date of purchase the product shall be free of defects in material and under normal use and that in fulfillment of any breach of such warranty DSC shall at its option repair or the defective equipment upon return of the equipment to its repair depot This warranty applies only to defects in and workmanship and not to damage incurred in shipping or handling or damage due to causes beyond the con of DSC such as lightning excessive voltage mechanical shock water damage or damage arising out of abuse alter or improper application of the product foregoing warranty shall apply only to the original buyer and shall be in lieu of any and all other warranties whether or implied and of all other obligations or liabilities on the part of DSC This warranty contains the entire war DSC neither assumes responsibility for nor authorizes any other person purporting to act on its behalf to modify or change this warranty nor to assume for it any other warranty or liability concerning this product no event shall DSC be liable for any direct indirect or consequential damages loss of anticipated profits loss of time or other losses incurred by the buyer in connection with the purchase installation or operation or failure of this product recommends that the entire system be completely tested on a regular basis However despite frequent testing due to but not limited to criminal tampering or electrical disruption it is possible for this product to fail to per as expected Digital Security Controls Ltd Canada www dsc com Support 1 800 387 3630 in Canada 29005945 R004 Multiple Wireless Receiver Module Instructions PC5320 connects to the primary Keybus of a control panel and provides four secondary 4 wire con for up to four wireless receivers The PC5320 does not provide additional zones but enables 32 zones to be distributed over a greater area When programming the first wireless receiver mod information all of the information is stored identically in all of the connected modules 1 PC5320 Module Range 12VDC 14VDC plus current draw of each receiver module Receiver Modules All receivers MUST be the same v3.0 or greater v3.0 or greater v3.0 or greater v3.0 or greater version Control Panels Field LEDs on the PC5320 indicate the status of the connected receiver modules The four LEDs on the PCB indicate the status of the connected receivers The LEDs will not turn on until at least one wire zone serial number has been programmed If the PC5320 module loses communication with the the corresponding LED will flash If there is a problem with the Keybus between the panel and the all LEDs will flash Supervision zones are supervised by all of the receivers connected A zone supervisory trouble will occur if a transmit supervisory signal is not received by any of the connected receivers during the programmed time period Tampers Violations and Restorals tampers violations and restorals are processed by the PC5320 When a receiver connected to the detects a tamper violation or restoral the PC5320 will send the information to the panel Tampers Troubles PC5320 tamper has a tamper input If the PC5320 has a tamper condition the panel will display Tamper If a receiver connected to the PC5320 has a tamper condition the panel will display Tamper The tamper trouble will not be restored until the tamper is restored on the PC5320 mod and all connected receivers Refer to Figures 1,2 and control panel Installation Manual for wiring details Select a location Select a location that ensures that the maximum wire run distances do not the guidelines indicated in Figure 2 The PC5320 can be mounted in the existing control panel or a plastic housing refer to the control panel Installation Manual Locate module so that service per will have easy access to the LEDs for troubleshooting and diagnostics Remove System Power Install PC5320 Module Insert the three standoffs provided into the cabinet Press firmly standoffs click into place Align the module mounting holes over the standoffs and press module into place Route the secondary bus wire in accordance with local regulations Wiring Receivers Wire the receivers to the secondary terminals of the PC5320 module as fol RED BLK and YEL are common to all receivers Connect the GRN wire of each receiver to GRN1 GRN3 and GRN4 as required NOTE One receiver MUST be connected to GRN1 to ensure proper operation NOTE Ensure that the connections to the terminals are secure before applying power Enroll Zones Refer to the receiver Installation Manual to enroll wireless devices Enroll each wire device and then program the zones and partitions as required The control panel sees the the PC5320 as a single receiver Programming is passed through the to all receivers so that they are all programmed identically Perform Module Placement Test module placement test is used to find a good location for the transmitter Perform multiple module tests before mounting a transmitter to ensure good placement refer to the receiver Installation for more information PC5320 will send the best test to the panel For example if one receivers indicates a test result one displays a test result then a test result will be displayed The control panel will not allow a module placement test on a zone if one or more receivers do not a serial number for a zone programmed The keypad will emit a steady error tone when the zone is entered This can happen if a receiver is added or replaced after the initial programming If a is added or replaced after initial programming all wireless data must be programmed again The can be downloaded or programmed using a keypad When programming using a keypad the correct wireless information may appear on the display the information by typing over the displayed information with the same information PC5132 Programming programming is not allowed if any of the receivers connected to the PC5320 are in supervisory i e missing from the Keybus If a receiver is removed from the PC5320 the PC5320 supervision be reset To reset PC5320 supervision turn ON option 1 in section 804 subsection 97 After supervision the PC5320 will automatically turn the option OFF 8 Installer Code 804 97 1 PC5320 Enrolled Field Used Used Used Used Used Used Used If a wireless zone is vio when in Installer Program the zone will show as when programming is After exiting program ensure that the status of wireless zones is correct If a zone indicates it is vio when it is actually secure

Related Files