PC6216 Module Instructions Introduction PC6216 is an output module with 16 programmable outputs Specifications 16 output low current module 12V 50mA max each drawn from Ebus Up to 9 modules per system 9 modules programmable as alarm or zone annunciators Each of the 9 modules programmable for all 16 outputs output options determined by the control panel version Connects to control panel via 4 wire Ebus Nominal current draw of 30mA Tamper contact input Cabinets PC4003C PC4006C PC4001C 4002C Installing the PC6216 Unpacking PC6216 package should include the following parts One PC6216 circuit board 4 plastic stand offs Mounting PC6216 should be located inside a compatible cabinet in a dry secure location Preferably it should be at a convenient distance from the connected devices the following steps to mount the unit Press the four plastic stand offs through the mounting at back of the cabinet Secure the cabinet to the wall in the desired location Use wall anchors when securing the cabinet to plaster concrete brick or other surfaces Press the circuit board into the plastic stand offs to secure module to the cabinet the unit is mounted wiring may be completed and Wiring beginning to wire the unit ensure that all power AC and battery is disconnected from the control panel the following steps to complete wiring Connect the four Ebus wires to the PC6216 Connect the black yellow and green Ebus wires to the RED BLK and GRN terminals respectively Complete all output wiring as illustrated below latching output will cause the status of all 16 outputs to latch during a Ebus reset To do connect as shown above When using the PC6216 with the Relay Output Indicator Voltage Output connection you must short Ebus Red to V Standard connection diagram above to ensure proper operation you are using an external power supply Latching Output Ebus Red to V is NOT required Connect the external tamper switch if used the wiring diagrams for further information refer to the System Installation Manual for information on limitations regarding product and function and information on the limitations as to liability of the manufacturer Applying Power all wiring is completed apply power to the control panel the battery leads to the battery then connect the AC For more information on control panel power see the control panel System Manual Do not connect the power until all wiring is complete a Custom Group Scroll to System Area press PGM Outputs press 4216 Options press Scroll through the list of PC6216 modules to choose the you want to program 01 09 Press Scroll through the available options to choose a custom Press to select To exit press a Custom Group you have assigned a PC6216 module to a custom group you to program the 16 outputs in the group Scroll to System Area press PGM Outputs press 4216 Custom press Scroll to the custom group you want to program 01 09 Enter the number of the output to be programmed 01 16 Enter the number of the output option to be used for that Refer to your system Programming manual for of the available programmable output options Testing the PC6216 you have enabled the lamp test option on the PC6216 master users will be able to conduct a lamp test The LEDs on the PC6216 modules with the lamp test enabled turn on for 2 seconds to the Maintenance Manual for instructions Scroll to Module Hardware press then scroll to To exit press Enrolling and Programming the PC6216 the instructions below for enrolling and programming PC6216 module Refer to your System or Programming for more information on programming must enroll the PC6216 module with the panel before you program it After you enroll the module the system will if you want to enable lamp testing on the module See 4.3 for a description of the lamp test feature these steps to enroll the module s At a PC6010 system LCD keypad enter Installer 8 Installer code Module press Scroll to PC6216 16 O P press The LCD keypad displays Create Tamper on Desired Unit and then restore the PC6216 module open and close the tamper switch if one is installed on module OR momentarily disconnect the jumper wire between the and COM terminals LCD keypad displays PC6216 nn Enrolled where nn the number of the PC6216 module Record the number of the PC6216 module in the worksheet opposite Press any key The keypad displays Lamp Test Y N Press to toggle between yes and no To exit press To exit module enrollment press If you need to change the Lamp Test option on a PC6216 after it has been enrolled you must delete and then re enroll module the PC6216 module to follow one of 9 custom custom group is a set of 16 programming choices that to the 16 programmable outputs on each PC6216 Example a PC6216 is assigned to custom group 01 which output 05 is programmed as output option 18 follow for zone 020 which is a fire zone LED 5 turns when zone 020 is in alarm and turns off when zone 020 restored and a fire reset is performed If you assign a PC6216 to a custom group you must also assign an output to each programmable output in the group More than module may follow the same custom group Worksheet Options 0 06 3 01 09 Module the module number of the PC6216 module here Number Options see section 4.2 your programming choice for each PC6216 module here See module options below Module Options Custom Group 1 Custom Group 5 Custom Group 9 Custom Custom Group 2 Custom Group 6 Custom Group 3 Custom Group 7 Custom Group 4 Custom Group 8 you will use a Custom Group to program the PC6216 module you need to program the Custom Group that will used Record your programming choices for the relevant group below See your System or Programming Manual a list of valid output options Group l l l Output 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Seismic Timer Group Group

Related Files