DSC Power432 - Keypad zones on RF5501 432-632 rev 005

File Preview
File Preview
Click below to download for free

File Data

Name dsc-power432-keypad-zones-on-rf5501-432-632-rev-005-9548027163.pdf
Type PDF
Size 636.92 KB
Downloads

Text Preview

Programming Keypad Zones RF5501 433 v5.0 Power432 PC1555 Power632 RF5501 433 has a terminal This terminal can either be used as a zone input or a output The zone input can be used as any zone on the system from 1 through 8 If the zone is assigned a zone number that is present on the main panel it will replace the zone and the zone on the main panel will be disabled keypad zones on the RF5501 433 is a five step process Assign the keypad to a slot number Program a definition for the zone Assign the zone to the keypad slot Assign the zone to the system Enable the keypad zone Sections 000 0 001 020 202 804 90 Assignment 1 to 8 Definitions Zone Assignment Assignment Zones 1 to 8 Options to enable keypad zone 1 Keypad Assignment use keypad zones each keypad must be assigned to its own slot 1 to 8 To assign a keypad a specific slot perform the following a two digit number The first digit is the partition the keypad will be assigned to 0 for operation or 1 for partition 1 The second digit is the slot the keypad will be assigned to 1 8 Installer Programming Keypad Assignment Section Partition and Slot Assignment Section you are using keypad zones DO NOT assign more than one keypad to the same 8 Installer Code 000 0 LCD5500Z keypads are being used one keypad must be assigned to slot 8 for purposes 001 Zones 1 to 8 2 Keypad Zone Definition must be defined before they will operate Depending on the control panel being used 30 different zone definitions are available Enter Section 001 and program the 2 number corresponding to the required zone definition for each zone 3 Keypad Zone Assignment Section is used to program which zone will be assigned to which keypad slot Program the zone number that will be assigned to the keypad in the corresponding slot Enter data if no keypad is assigned to the slot or if the zone input on the keypad will not be used example installation has three LCD keypads assigned to slot 1 2 and 8 at least one LCD must be to slot 8 for downloading purposes to be used as zones 6 7 and 8 respectively section 020 with the following data 4 Assignment Zones 1 8 will not function until they are enabled Ensure that all zones being used are enabled by ON the appropriate option in Section 202 Keypad zones can only be assigned to zones 1 to 8 5 Enable Keypad Zone enable the terminal on the RF5501 433 keypad as a zone input turn option 6 ON in 804 subsection 90 Tips Slot 5 00 Slot 6 00 Slot 7 00 Slot 8 08 Slot 1 06 Slot 2 07 Slot 3 00 Slot 4 00 202 Zone Enable Zones 1 to 8 Keypad zones will use the same EOL resistor option as the panel normally closed or end of line resistors a powered detector is being connected to a keypad zone use RED and BLACK of the connection for power The built in Low Temperature Sensor requires the zone input If it is being used the input will not be available for use Test the keypad zone and ensure it is displayed on the keypad

Related Files