Wireless Zones LCD5501Z-433, RF5501-433 (Power864) wireless receiver can be used to connect up to 32 wireless detection devices. Each wireless requires a zone. wireless zones is eight-step process: Connect the wireless receiver to the KEYBUS Programming the zone definitions Programming the zone attributes Programming the zone assignments Programming the Zone Serial Numbers Disabling the Supervision of Panic Zones Programming the Wireless Supervisory Window Performing a Module Placement Test Sections: [001] [002] [101] [132] [202] [261] [804], [01] [32] [804], [82] [85] [804], [81] [904], [01] [32] Definitions Attributes Zone Assignment Serial Number Device Supervision Supervisory Window Placement Test 1 Connect the wireless receiver to the KEYBUS the four KEYBUS terminals of the wireless receiver to the four KEYBUS terminals of the control panel. If the receiver is not connected to the KEYBUS the wireless data cannot be 2 Program the Zone Definitions wireless zones will operate on the system, they must be defined. Zones 1 to 16 Definitions Zones 17 to 32 Definitions Only the first 32 zones can be programmed as wireless. Do not define wireless zones as [07], [08] or [09]. If using wireless smoke program zone definitions [87] or [88]. 3 Program the Zone Attributes panel must be told which zones are wireless. Turn Option [8] ON for all wireless zones in [101] to [132]. 4 Partition Zone Assignment any zone will operate on the system, the zone must be assigned to a partition. Turn ON correct toggle option in the appropriate Section for all zones preset on the system. 5 Enroll Wireless Devices the ESN number for each wireless detection device in Section [804], subsection [01] to [32]. HEX digits may be present in the ESN number. Use the following table to program [202] Section [205] Partition 1 Zone Assignments Zones 1 to 32 [210] Section [213] Partition 2 Zone Assignments Zones 1 to 32 [218] Section [221] Partition 3 Zone Assignments Zones 1 to 32 [226] Section [229] Partition 4 Zone Assignments Zones 1 to 32 [234] Section [237] Partition 5 Zone Assignments Zones 1 to 32 [242] Section [245] Partition 6 Zone Assignments Zones 1 to 32 [250] Section [253] Partition 7 Zone Assignments Zones 1 to 32 [258] Section [261] Partition 8 Zone Assignments Zones 1 to 32 HEX digits. [A] [B] [C] [D] [E] [F] [*][1][*] [*][2][*] [*][3][*] [*][4][*] [*][5][*] [*][6][*] 6 Disabling Supervision of Panic Zones wireless Panic Pendent (WLS918-433) does not send a supervisory signal. Supervision be disabled for these zones to prevent the panel from generating a zone fault trouble Turn the corresponding Option OFF in Section [804], subsection [82] to [85] for all panic pendants zones. 7 Wireless Supervisory Window transmitters check in with the wireless receiver every 64 minutes. The wireless window is programmed in 15-minute increments. For example, data [32] = 8 hours, [96] = 24 hours. Program the desired supervisory window in Section [804], subsection [81]. If signal is not received from the transmitter, a zone fault trouble will be generated. 8 Perform a Module Placement Test wireless transmitters must be tested. To test a wireless transmitter, enter Section [904], [01] to [32] (the zone to be tested). Activate the device as indicated below: Create/restore a tamper by removing the back plate then replacing it Hold a magnet near groove marked on outer rim of bracket Create/restore tamper by pressing the Tamper Tab for five seconds Create/restore a