
File preview
Click below to download immediately for free
File data
- Filename: 2351690847_DSC_TL-250_with_4020_Quick_Install_Guide_WEB.pdf
- File size: 607 KB
- File type: pdf
- Download count: 58
Text Preview
Install Guide February 2, 2006 with 4020 Quick Install Guide Receivers III with a DRL3-IP line card Panels 4020 version 3.31 or greater (Rev04B hardware require). Overview T-LINK TL250 is a network communicator that sends alarm system information to the central and allows you to also perform uploads and downloads of the panel through the DLS you Begin programming the T-Link TL250 module, obtain the following information from the Network The static IP address for the T-Link TL250 module (only if static IP address is going to be The subnet mask for the T-Link TL250 module (only if static IP address is going to be The receivers IP address The gateway IP address 1 – Resetting to Factory Defaults Defaults Remove power from the T-Link TL250; disconnect battery and the control panel if Connect a jumper wire between the PGM1 and IN1 terminals Apply power to the system Wait approximately 20 seconds then remove the jumper between PGM1 and IN1. Install Guide 2 – Connect the TL-250 to the Alarm Control Panel Secure the T-Link module to the side of the cabinet using the supplied standoffs With both AC and battery disconnected from the DSC control panel, wire the T-Link TL- to the panel using the supplied cable Wire the panel’s AUX + and – to 12V and GND terminals of T-Link TL-250 Apply AC and DC to the main control panel. Both the T-Link TL-250 and the panel should Perform necessary programming that is required up 3 – Programming Program the Hex digits [CAAA] in the telephone number that will be used for T-Link communications Section [0004000000] Program YES for Enabled option Section [000401] using DLS communication over T-Link then program YES for Enabled Section Program the dialer direction options for the phone number that has been programmed to T-Link communications Section [000400XX02] where XX = telephone number T-Link module programming options Section [000406] Program the static IP address for the T-Link module Section [001] Program for DHCP Program the subnet mask for the T-Link module Section [002] this option will be if the unit is set for DHCP Program the receiver static IP address Section [007] the receiver is on a different network segment than the T-Link module, the gateway associated with the T-Link module must be programmed Section [008] Program the T-Link account number Section [003] After all T-Link TL250 module programming is complete, you must restart the module so programming changes will take effect. To restart the T-Link module enter the digits in T-Link TL-250 programming section [999] and wait 15 seconds for the module to Once complete, press the [#] key to exit T-Link TL250 programming. Install Guide 4 Testing Verify that the STAT LED is flashing once every 5 seconds, if not please procedure to the Trouble Shooting section Call the Central Station and put your account on test Trip a zone on the DSC control panel Call the Central Station and verify that the correct signal was received Shooting – LED Diagnostics LED will turn on when the network is present and will blink when there is network activity. LED will remain off for 10BaseT network connection and will be on to indicate 100BaseT connection. will blink to show network activity. Status The STAT (Status) LED will normally blink once every 5 seconds. Should a be present, the LED will blink a number of times (as per table) with a one second pause restarting the sequence. Should there be more then one trouble present, the LED will blink a rate that is equal to the highest pr