Fire-Lite 1412-1424 Smoke Detector

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-1412-1424-smoke-detector-8270495163.pdf
Type PDF
Size 760.64 KB
Downloads

Text Preview

July 14 1998 and 1424 Ionization Smoke Detectors Conventional Initiating Devices Fire 1424A Fire Marshal NO 1925 System Sensor 1400 Series direct wire ionization detectors respond quickly to fast flaming fires as by UL 268 a photoelectric smoke detector is faster detecting slow smoldering fires The unipolar dual sensor has the sensitivity needed to quickly de smoke and the stability needed to avoid false alarms Detects both visible and invisible smoke Used with UL listed control panels Unipolar ionization sensing chamber Provides exceptional stability Factory preset 1.9 nominal sensitivity Stable operation in air velocities up to 1,200 feet per 7.6 meters per second Removable cover for field cleaning Visible LED cid 147 blinks cid 148 in standby latches in alarm Sealed against dirt insects and back pressure Three year limited warranty Field metering of detector sensitivity using MOD400R Built in test switch Low standby current Built in tamper resistant feature Direct surface or electrical box mounting Remote LED option using RA400Z Insect resistant screening 0.020 0.508 mm openings SEMS screws for easy wiring for protection of life and property Superior to photo detectors in detecting fast flaming fires Superior bipolar detectors in avoiding false alarms AND OPERATION 400 Series ionization smoke detectors contain a unique source dual unipolar chamber detection design which sense the presence of smoke particles produced by combustion as well as slow smoldering fires Addi key features include a blinking LED standby status an easily visible alarm indication and provision convenient field test and metering back of the detector is sealed to block back pressure flow The chamber is protected by a fine mesh 0.020 mm screen to minimize problems with dust dirt and If cleaning is required it is easy to remove the with tool CRT 400 and obtain access to the screen chamber to perform a thorough cleaning 1412 1424 detectors are intended for use with UL listed control panels Easy to install and main this detector is designed for direct surface mounting bracket included or mounting to a 4 101.6 octagonal or smaller box Easy to wire screw termi allow fast and simple field wiring of in out and remote connections Fire cid 149 Lite control panel specifications for the maxi allowable loop resistance for the particular four wire panel to be used Installation and maintenance in are packaged with each detector prevent wiring mistakes observe polarities and make that each conductor is identifiable For further in refer to NFPA 72 and to local Authority Having document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all specific applications or all requirements All specifications are subject to change without notice For information contact Fire cid 149 Lite Phone 203 484 7161 FAX 203 484 7118 Clintonville Road Northford Connecticut 06472 and Manufacturing System Certified to Standard ISO 9001 in the U S A cid 151 Page 1 of 2 LINE INFORMATION smoke detector 12 VDC direct four wire smoke detector 24 VDC direct four wire End of line relay module 12 or 24 VDC Annunciator LED Field test module for all of the System Sen 400 Series smoke detectors Tool four wire ionization voltage 1412 12 VDC 1424 24 VDC current consumption maximum 100 cid 181 A current consumption maximum 77 mA for 1412 mA for 1424 voltage range 11.3 to 17.3 VDC for 1412 20 29 VDC for 1424 LED local alarm yes LED annunciator capability no contact ratings resistive or inductive 60 power load Alarm contacts Form A 2.0 A 30 VAC Auxiliary contacts Form C 0.6 A 110 VDC A 30 VDC 1.0 A 125 VAC 2.0 A 30 VAC base diameter 5.5 13.970 cm cover height 7.925 cm cover diameter 3.3 8.382 cm 0.683 pounds 310 grams options 4 101.6 mm square box 1.5 38.1 minimum depth with plaster ring 3.5 88.9 mm or 101.6 mm octagonal box 1.5 38.1 mm minimum or 50 mm 60 mm or 75 mm boxes Wiring 12 3.25 mm to 18 AWG 0.75 mm twisted pair rec temperature range 32 cid 176 F to 120 cid 176 F 0 cid 176 C to humidity 10 to 93 non condensing velocity rating 1,200 feet 365.76 m per minute DIAGRAM 1412 1424 2 of 2 cid 151 DF 50493

Related Files