Fire-Lite SD355CO Datasheet

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-sd355co-datasheet-3694815270.pdf
Type PDF
Size 718.80 KB
Downloads

Text Preview

SD355CO Photoelectric Detector fire and carbon monoxide CO detection combined in a addressable device provides a practical solution for today SD355CO Advanced Multi Criteria Fire CO Detector is a plug addressable device that provides both fire and carbon monoxide detection For fire the detector combines four separate sens elements in one unit smoke CO light flame and heat to sense components of a fire This approach enables enhanced to real fire with heightened immunity to nuisance particu For CO the detector electrochemical sensing cell creates a signal for life safety CO detection is a colorless odorless and deadly gas that is virtually impossi to detect with the human senses It is released whenever car fuels from fossil fuels to firewood burn without enough to form CO2 Because the potential exists for dangerous lev of CO to accumulate in almost any building legislation mandat the use of CO detection in commercial spaces continues to across the U S The SD355CO is listed to the UL 268 stan for smoke detectors and the UL 2075 standard for system con life safety carbon monoxide monitoring SD355CO should be used in conjunction with the B200S intelli sounder base which can generate either a Temporal 3 pattern fire or a Temporal 4 pattern for CO alarm indication SD355CO can also be used with the B210LP 6 standard base B501 4 standard base the B224BI base or the B224RB relay The SD355CO fire alarm control panels ES 50X C and compatible with Unique ability to detect all four major elements of a fire smoke heat and light flame Separate CO detection signal Highest nuisance alarm immunity Automatic drift compensation of smoke sensor and CO cell Uses only one address on the SLC RealTest CO testing capability Separates audible signal for fire or CO alarm when used with the base CO cell end of life warning and fault LiteSpeed operation SPECIFICATIONS 3.46 8.79 cm high x 6.875 17.46 cm diameter installed in base weight 4.6 oz 130.41 g Ivory humidity range 15 90 relative humidity non con temperature 32 to 100 0 to 38 velocity 0 4000 ft min 0 to 20 m sec Devices SPECIFICATIONS Voltage range 15 32 volts VDC current max avg 300 24 VDC one communica every 5 seconds with LED blink enabled Alarm Current LED on 7.2 mA 24 VDC ALARM ACTIVATION LEVELS activation levels as defined by UL Standard 2034 of CO Maximum Alarm Time Response 5 PPM 5 PPM 10 PPM min not less than 60 min min not less than 10 min min not less than 4 min Information SD355CO Advanced Multi Criteria photoelectric smoke CO B210LP Standard base B200S Sounder base B224RB Relay base B244BI Isolator base B501 Base without flange M02 04 00 Detector test magnet M02 09 00 Telescoping test magnet Listings and Approvals listings and approvals below apply to the SD355CO In some certain modules may not be listed by certain approval agen or listing may be in process Consult the factory for the latest list status UL S1059 CSFM 7275 0075 0505 4 27 2018 Page 1 of 2 is a trademark and Fire Lite Alarms and Realtest are registered of Honeywell International Inc by Honeywell International Inc All rights reserved Unauthorized use of this is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Fire Alarms Phone 800 627 3473 FAX 877 699 4105 of Origin Mexico 2 of 2 DF 60963 B 4 27 2018

Related Files