Gamewell-FCI 1415 Ionization Detector

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-1415-ionization-detector-1952807643.pdf
Type PDF
Size 640.33 KB
Downloads

Text Preview

1415 Sensor Smoke Detector Uses a unique dual unipolar sensor that provides stability Offers an easy plug in of the head to base Provides the following built in features Tamper resistant Test switch Visual alarm indicators Displays a 360 view angle of alarm LEDs Compatible with the Gamewell FCI fire alarm control Performs field adjustable sensitivity and field metering detector sensitivity Furnishes insect resistant screening 020 508 mm a removable insect screen and cover for field Sealed against dirt insects and back pressure ISO 9000 2000 Company MEA R LISTED System Sensor 1451 ionization type smoke detectors specifically designed to meet the performance require of fire detection and fire alarm systems The 1451 detector uses a state of the art dual unipolar chamber The detector is designed to provide area detection and when installed in a two wire base compatible with Gamewell FCI fire alarm control panels detectors operation and sensitivity can be tested in 1451 detector is built of plug in construction and plugs the same base as the 2451 Series photoelectronic detectors making both models interchangeable bases are available for two wire four wire and 120 four wire operation visible LEDs on each detector flash approximately ten seconds indicating that power is being applied to detector The LEDs light steadily when the detector is alarm A remote LED annunciator is available as an accessory 1451 detector is Listed for use inside ducts up to a of 1,200 FPM testing is performed by placing a test magnet the cover The LED on the detector should light 5 seconds metering of detector sensitivity may be performed the aid of a voltmeter and Test Kit MOD 400R Sensitivity 1.5 ft Voltage Humidity 10 93 relative humidity Velocity FPM ft flame retardant plastic inches 15.7 cm inches 8.1 cm lb 277 g 35 VDC 24 VDC nominal to 120 F 0 to 49 C are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 by Honeywell International Inc All rights reserved Rev C page 1 of 2 On a 4 inch square box with or without plaster ring or adapter Minimum depth 1.5 inches On a 3.5 or 4 inch octagonal box Minimum depth 1.5 On a single gang box Min depth 1.5 inches the detector into the detector base Turn the detec clockwise until the detector locks into place use the tamper proof feature break the smaller tab on scribed line in the tamper proof tab located on the mounting bracket Install the detector To remove detector from the base when using the tamper proof insert the blade of a small screwdriver into the on the side of the base and push the plastic lever from the detector head This will allow the detector to rotated counterclockwise for removal The decorative ring must be removed in order to the head when using the tamper proof feature tamper proof feature may be defeated permanently by the plastic lever off the base The number of two wire smoke detectors which can accommodated per zone varies with different control Consult the control panel instruction manual to the capacity to NFPA 72 Chapter 5 3 Sensing Fire for spacing location of detectors and other may be tested in the following ways Place a test magnet against the cover opposite the test socket See illustration The detector should into alarm within 5 seconds Field metering of detector sensitivity may be performed the aid of a voltmeter and Test Kit MOD 400R For complete procedure refer to the Installation and Instructions furnished with each detector programs should be adapted to the individual We recommend at least an annual cleaning the unit The detector screen and cover assembly can removed revealing the sensing chamber A vacuum can be used to remove dust from the screen and sensing chamber For the complete procedure to the Installation and Maintenance Instructions fur with each detector EC ESSED SW ITCH M PER T M O D U LE C K ET s Show Position of Test M agnet SH R EC ESSED ITC H W ITH A 0.1 A X D IA M ETER O L EM O VA B LE O VER FO R LEAN IN G EM O VA B LE R EEN C K PR O N G 1 To prevent detector contamination during con smoke detectors must be protected from dust contamination until the area is clean and dust free see 72 5 3.7.1.3 Information Detector two wire A four wire 24 VDC operation A A A C four wire 120 VAC operation A C Supvervisory alarm indicator relay 24 VDC B Test kit Number Alarm Current Supervisory Current Current Supervisory Current Contacts Contacts Alarm Current 007 A Alarm Current 015 A load A 2.0 A 30 VAC DC C 2.0 A 30 VAC DC 1.0 A 120 VAC Alarm current of detector is limited by control panel device circuit Rev C page 2 of 2 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118

Related Files