Gamewell-FCI Flex 4 & Flex 8 CS-2081

File Preview
File Preview
Click below to download for free

File Data

Name gamewell-fci-flex-4-flex-8-cs-2081-2104867359.pdf
Type PDF
Size 714.24 KB
Downloads

Text Preview

Description Gamewell Flex 4 and Flex 8 Fire Alarm Control Panels designed for small to medium commercial residential in and industrial occupancies Simple and easy con of the microprocessor based controls is accom via DIP switches product flexibility allows compliance with the specific requirements at each installation Two standard are available The Flex 4 includes 4 Class B B Initiating Device Circuits IDCs which are easily and wired to perform as 2 Class A Style D For signaling an alarm condition the Flex 4 provides Notification Appliance Circuits NACs that may be wired for A B Style Z Y performance and are rated for loads up 1.7 Amperes each twice the circuit capacity the Flex 8 provides 8 Class B which are easily configurable as 4 Class A circuits and Class A B NACs Each NAC is also rated for a maximum of Amps with total notification appliance power for the Flex at 5 Amps maximum A Flex 4 may be expanded in the field provide the circuit capacity of a Flex 8 by installing a Circuit Module CEM The CEM provides an additional 4 B 2 Class A IDCs and 2 Class A or B NACs initiating circuits of the Flex 4 and Flex 8 are factory set to for Class B Style B wiring performance Through programming all circuits can easily be converted to Class Style D circuits integral 6 Amp power supply is included in both products provide system power 4 wire resettable smoke power 24 100 mA and up to 5 Amps of notification appliance Flex 4 and Flex 8 use simple DIP switches for IDCs and NACs as well as enabling and of system functions such as signal silence fire drill auxiliary disconnect Notification circuits may be for audible or visual devices and silenceable or operation The Flex 4 and Flex 8 allow for verification on all Initiating Device Circuits IDCs IDCs may be optionally configured for Waterflow 3 Flex 4 or zones 3 7 Flex 8 or Latching Non Supervisory zone 4 Flex 4 or zones 4 8 Flex 8 4 Flex 8 Alarm Panels Listed MEA Approved Initiating Device Circuits IDCs may be individually for General Alarm Waterflow Supervisory Alarm Verification Supervisory operation may be Latching or Non Latching Notification Appliance Circuits NACs may be programmed as Silenceable Non Silenceable Auto Silenceable Coded March Time Temporal Code California Code 5.0 Amps of total NAC power Common Alarm Supervisory and Trouble contacts Resettable four wire smoke detector power 100 mA Integral Walk Test operation EIA 485 interface for up to 3 model RA8 Remote Annunciators Polarity Reversal and City Tie connection optional Digital Alarm Communicator Transmitter DACT optional Relay by zone capability with RY4 Flex 4 or RY8 Flex 8 modules Rev 1201 3 1 Digital Alarm Communicator Module RY8 Remote Trouble Indicator Annunciator and Programming Tool CFG Flex 4 and Flex 8 can meet the following UL installation system designations with indicated options selected Local Auxiliary using PRM Remote Station Protected Premises using DACT or PRM Central Station Protected Premises using DACT Type of Service Signaling A M WF SS SS is only Local or with DACT Non coded 4 Flex 8 Fire Alarm Control Panels Input Power Power Charging Capacity Device Circuits Compatibility Identifier Output Power Output Ratings Power Output Smoke Power Consumption Circuit Board Fuse Relays Trouble Supervisory Connection Indication Output resistor 30177 VAC 60 Hz 4 Amp 12 volt batteries in series to 24 Amp hours max VDC 003 A standby 1.5Vp p ripple 050 A max alarm power limited Amp maximum VDC unfiltered 1.7 Amp max circuit 5 Amp max power limited VDC unfiltered 3 A max power limited VDC unfiltered 100 A max 1.5Vp p ripple resettable power limited A standby 220A alarm Amp Amp resistive 28VDC Form C up to 3 RA8 Remote Annunciators single RTI Remote Trouble Indicator K Ohm 1 2 Watt 5 with spade lugs Listed 4 Flex 8 Optional Modules Annunciator 8 Zone Consumption Trouble Buzzer Consumption Alarm Communicator Transmitter Consumption Module 4 Form C Consumption Module 8 Form C Consumption Reversal City Tie Module Consumption A standby 090 A alarm A standby 035 A alarm A standby 120 A alarm A standby 160 A alarm 1 Amp resistive 28 VDC A standby 160 A alarm 1 Amp resistive 28 VDC A standby 3 A alarm Supervised City Tie 24 VDC unfiltered 210 A 14 Ohms trip coil NOT power limited VDC open 12 VDC 003 A 008 A max shorted power limited Reversal Expander Module Flex 4 only Consumption Device Circuits Compatibility Identifier Output Ratings A standby 120 A alarm VDC 003 A standby 1.5Vp p ripple 050 A max alarm power limited VDC unfiltered 1.7 Amp max circuit power limited Dimensions Space Humidity Rating H x 14 W x 5 D 12 AH batteries max non condensing 49 32 120 Rev 1201 3 Information 4 8 expandable microprocessor based Fire Alarm Control Panel with 4 B Style B or 2 Class A Style D Initiating Device Circuits IDCs 2 Class Style Z Y Notification Appliance Circuits NACs and a 6 Amp power supply up to 8 Class B Style B IDCs or 4 Class A Style D and 4 Class A Style Z Y NACs Allows for installation of one DACT Digital Alarm Communi Transmitter or one PRM Polarity Reversal City Tie Module and one RY4 or Auxiliary Relay Module Red surface or flush mount enclosure with CAT 60 locked door microprocessor based Fire Alarm Control Panel with 8 Class B Style or 4 Class A Style D Initiating Device Circuits 4 Class A B Style Z Y Appliance Circuits and a 6 Amp Power Supply Allows for Installation one DACT Digital Alarm Communicator Transmitter or one PRM Polarity City Tie Module and one RY4 or RY8 Auxiliary Relay Module Red or flush mount enclosure with CAT 60 key locked door Expander Module to field modify a Flex 4 to a Flex 8 Alarm Communicator Transmitter Module Transmits in ADEMCO Contact and SIA DCS protocols CFG configuration and diagnostics tool is required for Reversal City Tie Module Note Only one of a DACT or PRM module be used with the Flex 4 or Flex 8 Relay Module with 4 configurable Form C relays Relays programmable Relay by Zone Common Alarm Common Supervisory etc Relay Module with 8 configurable Form C relays Relays programmable Relay by Zone Common Alarm Common Supervisory etc Trouble Indicator with trouble LED and piezo buzzer Annunciator with common control features indicators and 8 bi colored Listed End of Line Resistor assembly with wire leads and spade lugs Configuration and Diagnostics programming tool for DACT of Manuals for the Flex 4 and Flex 8 product line 4 and Flex 8 Main Board Display replacement 12 VDC 4 Ampere Hour 2 required per panel 12 VDC 7 Ampere Hour 2 required per panel 12 VDC 12 Ampere Hour 2 required per panel and wiring information are provided for information only and are believed to be accurate Gamewell assumes no responsi for their use Data and design are subject to change without notice Installation and wiring instructions shipped with the product always be used for actual installation For more information contact Gamewell Gamewell Company Pleasant St MA 01721 508 231 1400 888 347 3269 508 231 0900 2001 Rev 1201 3 4

Related Files