Gamewell-FCI GWF-7075 – Addressable Fire Alarm Control Panel

File Preview
File Preview
Click below to download for free

Text Preview

Analog and Networking Systems Fire Alarm Control Panel Gamewell FCI GWF 7075 is an Addressable Fire Alarm Control Panel FACP GWF 7075 has a signaling line circuit SLC loop that is used to connect the detectors The SLC loop is capable of supporting up to 75 detectors and modules using the System Sensor Velociti Protocol and it also offers the built in for the SWIFT wireless fire alarm devices GWF 7075 is equipped with two configurable Notification Appliance Circuits that support a maximum output of 2.5A This panel communicates with the dual line digital and IP communicator including an optional cellular module GWF 7075 fire alarm control panel offers the following powerful features detector sensitivity day night thresholds drift compensation pre trouble maintenance alert calibration trouble alert GWF 7075 panel supports a variety of devices including the following RA 1000 Remote Annunciator 5880 LED I O Module GFPS 6S Intelligent Remote Power Supply 5824 Serial Parallel Printer Interface Module for printing system reports BENEFITS Built in support for up 75 detectors and 75 operating in mode Offers a four line LCD with 40 per line Available in a red or a cabinet GWF 7075 can be or flush used for Includes the date for Daylight Time Uses a JumpStart Auto feature easy programming Reports events to the Station by or by zone Contains a built in USB System programmable Supports up to four Offers a built in the front panel Provides a built in dual line digital communicator DACT IP optional cellular Firmware can be in the field wireless Each may include to 49 wireless Supports Class B Style and Class A Style 6 Style 7 configuration SLC and SBUS for models To identify the models refer the Compatibility to Gamewell Manuals DEVICES a list of compatible devices refer to the following Compatibility Addendum for Gamewell FCI P N 9000 0427 L8 SWIFT Intelligent Wireless Detectors 9021 60818 SWIFT Intelligent Wireless Modules 9021 60819 SWIFT Wireless Gateway P N 9021 60824 INFORMATION Intelligent Fire Alarm Control Panel Red Intelligent Fire Alarm Control Panel Accessories Remote Annunciator Black Dimensions 7.4 H x 9.1 W x 1.5 18.8 x 23.1 x 3.8 cm Remote Annunciator Red Intelligent Remote Power Supply Dimensions 16 H x 12.25 W 3 D 40.6 x 30.9 x 7.6 cm Serial Parallel Module Dimensions 6 H x 7.75 W x 1.44 D 15.0 x 19.4 x 3.6 cm LED I O Module Dimensions 7.75 H x 6 W x 1.94 D 19.4 x 15.0 x 4.8 cm Direct Connect Module Dimensions 1.31 H x 6.5 W x 2.13 D 3.33 x 16.51 x 5.40 cm Accessories Software Suite Provides programming upload and event reporting Remote Battery Box Cabinet Holds up to two Amp Hour batteries 16 W x 10 H x 6 D 40.64 W x 25.40 H x 15.24 D cm Accessories Remote Annunciator RA 1000 is a remote annunciator used to operate GWF 7075 Fire Alarm Control Panel FACP It to the control panel via the RS 485 system The RA 1000 is equipped with five status LEDs indicate Alarm System Silenced Supervisory AC Power Loss Trouble Intelligent Remote Power Supply GFPS 6S intelligent power supply delivers 6A of Appliance Circuit NAC power and offers synchronization for some appliances by the following manufacturers System Sensor Gentex Wheelock Sync Feature Restriction Not all devices can use the Sync To ensure that the selected device works with the Sync refer to the Compatibility Addendum to Gamewell FCI P N 9000 0427 L8 Faraday AMSECO GFPS 6S provides its own AC power connection charging circuit and backup battery for use the GWF 7075 FACP The output circuits can be as NACs or as auxiliary power for constant resettable or door holder Serial Parallel Module 5824 is equipped with one parallel and one RS serial port that allows the GWF 7075 to connect to any standard PC compatible printer to reports on site LED I O Module 5880 provides 40 programmable LED outputs and supervised dry contact inputs These devices an effective way to customize remote The GWF 7075 supports up to eight modules to offer maximum flexibility Direct Connect Module 5220 is a direct connect module used to connect a alarm control panel FACP to a city box or polarity communicator Technical Specifications Dimensions 15.12 H x 12.71 W x 3.33 D 38.40 H x 32.28 W x 8.46 D cm 25 lbs Red or Black Operating Temperature 32 to 120 0 to 49 0 to 93 relative humidity non condensing Primary AC 120 VAC 60 Hz 900mA Total Load 2.5A 27.4 VDC Class A Power Limited NAC Power 1A per NAC 2.5A Total Aux Power 27.4 VDC C Trouble Alarm Relay 2.5A 27.4 VDC Resistive Current 165 mA Current 310 mA Charging Capacity 7 to 35 AH Size 7 A H maximum allowed in the control cabinet Larger capacity batteries can be housed the BB 17F accessory cabinet AND HUMIDITY RANGES system meets NFPA requirements for operation at 0 49 120 and at a relative humidity 93 2 noncondensing at 32 2 90 3 the useful life of the system standby batteries the electronic components may be adversely affected extreme temperature ranges and humidity Therefore is recommended that this system and its peripherals be in an environment with a normal room of 15 27 80 GWF 7075 is designed to comply with the standard Standard UL 864 9th Edition STANDARDS 13 Sprinkler 15 Water Spray 16 Foam Water 70 72 Station Signaling Protective Signaling Systems Protected Premises Unit Water Deluge Service LISTINGS AND APPROVALS listings and approvals apply to the modules in this document In some cases certain or applications may not be listed by certain agencies or listing may be in process factory for latest listing status S1869 7165 1703 0500 COA 6255 CA Releasing Solenoids Asco T8210A107 24 VDC 3 A max 0 Hz Asco 8210G207 24 VDC 3 A max 0 Hz 9001 Certification a complete listing of all approvals and please visit System and Velociti are trademarks and is a trademark of International Inc is a registered of Kobishi America is a registered of Asco Power Inc is a trademark of LLC is a registered of Gentex Inc Windows and the Logo are registered or trademarks of Corporation is a registered trademark Underwriter Laboratories is a trademark of Inc document is not intended be used for installation We try to keep ou

Related Files