Gamewell-FCI InnovairFlex D4120 D4120 Duct Smoke Detector

File Preview
File Preview
Click below to download for free

Text Preview

InnovairFlex Series Duct Smoke Photoelectric Smoke Detector Photoelectric integrated low flow technology Air velocity rating from 100 ft min to 4,000 ft min m s to 20.32 m sec Versatile mounting options square or rectangular Plug in sensor offers superb false alarm immunity and latest sensor technology Broad ranges for operating temperature to 158 humidity 0 to 95 non condensing Patented sampling tube installs from front or back of the with no tools required wiring space with a newly added knockout One easy access Test Reset button and improved LED Patented interconnect feature for multi fan shutdown New high contrast terminal designations Built in short circuit protection from operator wiring Field selectable settings for configuring the detector Two DPDT Form C relay contacts 24 VAC DC or 120VAC 3242 1653 0207 S911 InnovairFlex Series D4120 4 wire photoelectric smoke detector features a pivoting housing that fits square and rectangular footprints and mounts to or rectangular ductwork This unit senses smoke in most challenging conditions operating in airflow from 100 to 4,000 feet per minute temperatures of to 158 and a humidity range of 0 to 95 percent A plug in sensor head offers improved alarm immunity and simple installation testing and The improved cover design isolates the sen head from the low flow feature for simple maintenance InnovairFlex housing provides ample wiring space a conduit knockout and a built in short circuit protec to prevent damage to sensitive components during The high contrast terminal designations make easy With a 2 1 sensor to power capability the board of the D4120 may be used to simultaneously a second D4S sensor i e supply and return side to 50 InnovairFlex detectors can be interconnected one unit senses smoke all interconnected detectors switch the relays and only the detector sensing smoke go into alarm thus pinpointing the fire source easy access Test Reset button makes it possible to test unit with the cover on Three DIP switches can be used configure the following field selectable settings cover tamper delay number of sensors to be controlled shut down on trouble option power board has two LEDs that can be used to indi the status of connected sensors A quick reference imprinted on the cover displays the LED status indi Standby Maintenance Trouble and Alarm The duct smoke detector can be customized to local codes and specifications without additional wir The new InnovairFlex product line is compatible with previous Innovair models including the remote test Duct smoke detectors are a substitute for open area smoke detectors a substitute for early warning detection a replacement for a building regular fire detection to NFPA 72 and 90A for additional information is a trademark of Honeywell International Inc GAMEWELL FCI are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Rev C page 1 of 4 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 www gamewell fci com by Honeywell International Inc All rights reserved Specifications air duct smoke detector shall be a System Sensor InnovairFlex D4120 Photoelectric Duct Smoke Detector The detector shall be UL Listed per UL 268A specifically for use in air handling systems The flexible housing of the duct smoke detector multiple footprints from square to rectangular The detector shall operate at air velocities of 100 feet per minute to 4,000 feet per 0.5 to 20.32 meters second The unit shall be capable of controlling up to 50 air handling systems when interconnected other detectors The detector shall be capable of providing a trouble signal in the event that the front cover is removed It shall capable of local testing via magnetic switch test button on the cover or remote testing using the RTS2 AOS Multi Signaling or the RTS151KEY Remote Test Station Terminal connections shall be of the strip and clamp method suitable for 12 wiring Specifications Dimensions Dimensions Temperature Range D4120 D4S to 158 to 70 D4P120 to 158 to 70 Temperature Range D4S to 158 to 70 D4P120 to 158 to 70 Humidity Range to 95 relative humidity non condensing Duct Velocity to 4,000 ft min 0.5 to 20.32 m sec in 37 cm Length 5 in 12.74 cm Width 2.5 in 6.36 cm Depth in 19.7 cm Length 9 in 22.9 cm Width 2.5 in 6.35 cm Depth lbs 1.14 kg Ratings supply voltage capacitance voltage time with RTS151 time by power down up time response time Test Requirements Using No Accessories standby current alarm current VDC max VDC min to 0.3 sec sec max sec max sec detector label mA 24VDC mA 24VDC VAC 50 Hz max VAC min to 0.3 sec sec max sec max sec detector label VAC 50 Hz VAC min to 0.3 sec sec max sec max sec detector label mA RMS 24VAC 60Hz mA RMS 120VAC 60Hz mA RMS 24VAC 60Hz 35 mA RMS 120VAC 60Hz 30 VDC resistive 2.0A 125 VAC resistive Ratings initiation contacts SPST 2.0A 30 VDC resistive auxiliary contacts DPDT 10A 30 VDC resistive 10A 250 VAC resistive HP 240 VAC HP 120 VAC Alarm auxiliary contacts shall not be connected to initiating circuits of control panels Use the alarm initiation contact for this contacts SPDT Current Loads at 24 VDC mA mA mA mA 12 mA mA Max Any combination of accessories may be used such that the given accessory loads are 110 mA or less at the Aux output and mA or less at the Alarm output mA Max mA Max mA Max mA Max mA Max mA Max Rev C page 2 of 4 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 the InnovairFlex Sampling Tube InnovairFlex sampling tube may be installed from the front or back of the detector The tube locks securely into place and can removed by releasing the front or rear locking tab Figure 3 illustrates the front locking tab 1 2 3 for 4 wire Duct Smoke Detector and Accessories 4 Wiring for 4 Wire Duct Smoke Detector and Accessories 1 24V Power Inputs accept a non polarized 24VDC or 24VAC 50 60Hz 120VAC Power Inputs accept only 120VAC 50 Connect power source to appropriate terminals of each detector See specifications for additional power supply information 2 Auxiliary contacts shown in standby position Contacts switch during alarm as indicated by arrows Auxiliary contacts are to be used for connection to the control panel See specifications for contact ratings 3 Supervisory contacts shown in standby position Open contacts indicate a trouble condition to the panel See specifica for contact ratings 4 Alarm Initiation contacts shown in standby position Closed contacts indicate an alarm condition to the panel See specifi for contact ratings 5 For additional information refer to the InnovairFlex D4120 Duct Smoke Detector Installation Instructions I56 2967 002R and the Duct Application Smoke Detectors Application Guide Notes on 2 1 Sensor to Power Capability 2 1 sensor to power capability is only available on the D4120 4 wire conventional models 2 1 sensor to power capability can be enabled using one D4120 and one D4S or two D4S and one D4P120 Interconnect Notes When using the interconnect feature all interconnected units must be powered using the same independe

Related Files