Xtralis Protocol HLITM Protocol High Level Interface Xtralis VESDA Open Protocol High Level Interface HLI links your with PC software monitoring tools Building Management BMSs and Fire Alarm Control Panels FACPs otherwise known There are two models available depending on whether you require between your host and VESDAnet to be master slave or Open Protocol HLI master slave the master slave model the host supervises the communications link itself and the HLI slave by regularly polling the HLI to determine there has been a change in the status of a detector on VESDAnet response to polling by the host the HLI generates a single response which sent back to the host In this way no unsolicited messages are sent from HLI to the host Depending on the polling strategy adopted the Master of a detector going into alarm Exact performance is dependent on polling strategy adopted Open Protocol HLI peer to peer the peer to peer model the host polls the HLI for information about on VESDAnet while the HLI sends unsolicited messages to the In this way both the HLI and host are responsible for supervising the link between them the peer to peer model the host can request and receive multiple from the HLI is a propriety communications protocol allowing your VESDA range of smoke detectors displays programmers and units collectively known as devices to communicate with each other on the one network VESDAnet is a fault tolerant protocol This means that if one direction of communication fails then your VESDAnet messages are transmitted in opposite direction or VHX 0310 access and monitoring of VESDAnet system data transfer HLIs are recommended for only They are not approved use as a primary reporting device available using the Protocol HLI Type VLC VLS VLP status Alert Action Fire1 Status System Zone Urgent Network Flow Filter Isolated Normalizing Scanning info Alarm thresholds name update Smoke level Alarm Fault status details list of active fault strings ASCII strings to each fault code controls Reset Isolate Test Scan or Normalize2 Slave only Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use www gamewell fci com GF12352 03 page 1 of 2 Protocol HLITM VESDAnet system with Open Protocol HLI mm x 98 mm x 40 mm in x 3.9 in x 1.6 in approx or VHX 0310 Consumption W Quiescent Voltage VDC Consumption mA Quiescent kg 0.9 lbs With RS 232 9 way serial cable RS 485 15 way cable male of Detectors Supported to 40 detectors your network has more than 40 detectors please contact your representative Support support is not available Warranty years Information Part number Protocol HLI Protocol HLI RS 232 9 way serial part RS 485 15 way cable VSP 511 part Americas 1 781 740 2223 Asia 852 2297 2438 Australia and New Zealand 61 3 9936 7000 Europe 41 55 285 99 99 UK and the Middle East 44 1442 242 330 contents of this document are provided on an is basis No representation or warranty either express or implied is made as to the obligation and without further notice Except as otherwise provided all warranties express or implied including without limitation any document includes registered and unregistered trademarks All trademarks displayed are the trademarks of their respective owners use of this document does not constitute or create a licence or any other right to use the name and or trademark and or label document is subject to copyright owned by Xtralis AG You agree not to copy communicate to the public adapt distribute transfer modify or publish any contents of this document without the express prior written consent of Xtralis 12352 03 number 21152 page 2 of 2 www gamewell fci com Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118

Related Files