Kidde 3101236-EN R05 FX-5 and FX-10 Series Operating Instructions

File Preview
File Preview
Click below to download for free

Text Preview

Frame these instructions and mount them adjacent to the control panel FX 5 and FX 10 Series Operating operating instructions are for the following FX Series conventional panel models FX 5 Series and FX 10 Series They are intended users who are trained and authorized to operate the control panel in event of an emergency additional information see FX 5 and FX 10 Series Technical Manual P N 3101172 EN no events Power LED is on All other LEDs are off The Power is always on except when operating on standby battery power events System Alarm LED is on one or more IDC Alarm LEDs on and the panel buzzer is on The system Waterflow LED is on if a switch is active events System Supervisory SUP LED is on one or more SUP MON LEDs are on and the panel buzzer is on events System Trouble LED is on one or more IDC or NAC TBL LEDs are on and the panel buzzer is on Depending on the the system Disable Annunciator ANN Trouble Battery BATT or Ground GND Fault LEDs may also be on events One or more IDC SUP MON LEDs are flashing and the buzzer is on to alarm signals Evacuate the area Notify the proper authorities immediately State the nature and of the emergency Be prepared to direct firefighters when they arrive alarm signals The protected premises may be occupied Do not silence signals or reset the panel unless you are authorized to do so and after all occupants have been evacuated silence alarm signals Press the Signal Silence Alarm On button for less than three The Signal Silence Alarm On LED on indicates that Silence is active Silence turns off all active audible notification appliances A new event or pressing the Signal Silence Alarm On button again turns notification appliances back on Signal Silence does not turn off coded signals city tie signals and alarm signals activated by a waterflow programming may inhibit Signal Silence for one minute after alarm are activated and may prevent Signal Silence from turning off notification appliances the panel Trouble conditions may affect the panel s ability to provide detection and indication of a fire Identify the source of the trouble notify authorized service personnel immediately silence the panel Press the Panel Silence button Silence turns the panel buzzer off New events will turn the panel back on If there are no new events the panel buzzer re sounds within 24 hours the panel Press the Reset button The Reset LED flashes at different intervals the system is resetting then turns off returns the panel to normal operation provided there are no active devices Before resetting the panel make sure all smoke detectors free from smoke and all manual pull stations are restored to normal programming may inhibit Reset for one minute after alarm signals activated a manual evacuation Press the Remote Disconnect button to avoid sending manual activation code to the CMS optional Press the Signal Silence Alarm On button for more than three The system Alarm LED steady and the Signal Silence On LED flashing indicates that Manual Evacuation is active Manual Evacuation feature places the control panel in the alarm e g activates the common alarm relay and turns on the Alarm turns on all fire alarm and city signals but not coded fire alarm and signals the central station Reset to cancel a Manual Evacuation recommendations and test the fire alarm system in accordance with NFPA 72 and local authority having jurisdiction Verify the correct fuse is installed at least once per year Replace the batteries every five years or sooner as required service contact Name Address Phone 2017 United Technologies Corporation 1 3101236 EN REV 05 ISS 10FEB17

Related Files