Kidde K85001-0369 -- 202 Synchronized Strobe

File Preview
File Preview
Click below to download for free

File Data

Name kidde-k85001-0369-202-synchronized-strobe-1208679354.pdf
Type PDF
Size 821.29 KB
Downloads

Text Preview

Synchronized MS 8A Series strobes are specially designed for use with compatible safety communication and control equipment to alert the hear impaired of a life safety event Strobes are available with 15 75 and 110 cd effective flash intensity They are fully compatible Genesis signals are shipped with standard wall mount style lens Where ceiling mount other languages or different lens are required Kidde offers optional LKW and LKC series Marking Kits These optional lens markings simply snap on the strobe Series strobes are designed for 16 to 33 Vdc operation and be connected to signal circuits that output a constant not voltage A diode is used to allow full signal circuit supervi and polarized connections are made to terminals that accept to 12 AWG 2.5mm wire strobe housing front plate is finished in red or white and is from durable and fire retardant high impact plastic with a textured surface Features UL 1971 listed synchronizing strobe strobes synchronize to the latest UL 1971 require when used with a synchronization source Genesis compatible Genesis and Integrity strobes on the same circuit meet UL synchronization requirements when used with an external module Approved for public and private mode applications 1971 listed as signaling devices for the hearing impaired UL 1638 listed as protective visual signaling appliances Rated for wall or ceiling installation Field changeable field markings language or standard marking is easily changed optional LKW and LKC series lens kits Screw terminal wire connection terminals speed installation and accept up to 12 AWG wire Fits one gang flush box for retrofit and renovation projects Optional color surface boxes available 1 of 4 D A T A S H E E T K85001 0369 to be used for installation purposes Issue 1.1 Catalog u Strobes Horns Bells Chimes04 05 20Technology that saves livesfirealarmresources com The installation of visible and audible signals are subject to national and local standards codes and ordinances your Authority Having Jurisdiction for device installation requirements application standards and minimum performance specifications are UL 1971 listed for use indoors as wall mounted public notification appliances for the hearing impaired Prevailing require strobes to be used where ambient noise conditions specified levels where occupants use hearing protection in areas of public accommodation Consult with your Authority Jurisdiction for details part of the Enhanced Integrity line of products MS Series exceed UL synchronization requirements within 10 mil other over a two hour period when used with a syn source Synchronization is important in order to avoid sensitivity strobes are fully compatible with Genesis Series signals The flash intensity of some visible signals may not be adequate alert or waken occupants in the protected area Research indicates the intensity of strobe needed to awaken 90 of sleeping persons is 100 cd Kidde recommends that strobes in sleeping rooms rated at at least 110 cd These devices will not operate without electrical power As frequently cause power interruptions further safeguards such as power supplies may be required cd 5A Series Strobes Output and Mounting models fit to a standard flush mounted North American one electrical box two inch 51mm deep minimum Optional indoor surface mount boxes are available Strobes cd 5A Series Strobes cd 3A Series Strobes be connected to signal circuits which output a constant not voltage Kidde recommends that these strobes always installed in accordance with the latest recognized edition of and local fire alarm codes cd 7A Series Strobes Output Output Output e grees e grees e grees Distribution Patterns 1971 WALL MOUNTED STROBE LIGHT OUTPUT cd 7A Series Strobes cd 4A Series Strobes cd 3A Series Strobes cd 8A Series Strobes cd 4A Series Strobes Output Output e grees e grees Output Output e grees e grees Output VIEW 20 30 100 100 VIEW mm 20 10 mm 20 30 Output Output mm Output Output mm mm lens wall orientation supplied Other lens markings are available see ordering table mm Output Output min min min min min min min min Output Output Output PLATE pan head slotted screws are provided to mounting plate to 1 gang electrical box 2 of 4 D A T A S H E E T K85001 0369 to be used for installation purposes Issue 1.1 Strobe an end of resistor on the device resistor with panel This unit is designed to be used on signal circuits that output a constant Do not connect this unit to a coded or pulsating voltage Electrical supervi requires wire run to be broken at each device Do not loop signal circuit field around the strobe terminals Wiring 24 Vdc Listed dc Alarm Panel circuit Current RMS Rating cd Vdc Vfwr Current Vdc Vfwr Vac cd Volts direct current regulated and filtered Volts full wave rectified Number 1971 Rated Strobe Output candela cd 1638 ULC S526 Rated Strobe Output Flash Rate Operating Volts Sources for Rating for Outdoor Rating Markings Connections Tube Enclosure Plate Finish Listings cd cd mA Draw Notes and Comments Current values are shown in mA UL Nameplate Rating can vary from Typical Current due to measurement meth and instruments used Kidde recommends using the Typical Current for system design including NAC Power Supply loading and voltage drop calculations Use the 16 Vdc RMS current ratings for filtered power supply and battery AH Use the 16 Vfwr RMS current ratings for unfiltered power supply Fuses circuit breakers and other overcurrent protection devices are typically for current in RMS values Most of these devices operate based upon heating affect of the current flowing through the device The RMS current the heating affect and therefore the trip and hold threshold for th

Related Files