Kidde K85001-0645 -- Explosionproof Smoke Detector

File Preview
File Preview
Click below to download for free

File Data

Name kidde-k85001-0645-explosionproof-smoke-detector-5937142086.pdf
Type PDF
Size 814.80 KB
Downloads

Text Preview

Explosionproof Detector 30 3013 30 3013 detectors are high performance smoke detectors for use in hazardous locations They are corrosion resistant feature a non conducting aluminum alloy retaining ring that the detector sensor against the effects of explosions and catastrophic events retaining ring mounts securely to a companion junction box offers several common port configurations for conduit con Together the ring and box provide a sturdy protective for the detector head 30 3013 advanced optical detector performs effectively with smoldering fires as well as quickly rising flames sensor module is hot swappable and intrinsically safe while This allows maintenance work to be performed without to declassify the protected area as a hazardous location integrated Trouble relay ensures that the 30 3013 detector performs as expected On board Alarm and Auxiliary relays easily with Kidde fire systems as well as auxiliary equip such as dampers and door closers Features High performance optical smoke detection Built in 0 20 mA output for easy Distributed Control System integration Self diagnostics for reliable operation Alarm Auxiliary and Trouble relays for annunciator and control connection On board LED provides local annunciation Non latching operation Convenient magnetic switch for manual testing FM Approved for smoke detection in Class I Division hazardous locations IECEx Zone approved IP44 ingress protection level suitable for onshore or offshore 1 of 4 D A T A S H E E T K85001 0645 to be used for installation purposes Issue 1.1 Catalog u Conventional Initiating DevicesTechnology that saves livesfirealarmresources com 30 3013 Explosionproof Smoke Detector features a rugged built to withstand environmental extremes Its integrated outputs make it ideal for a wide range of industrial appli while its agency approval ratings make it suitable for both and off shore facilities applications for the 30 3013 Explosionproof Smoke Detec include Indication LED located on the 30 3013 annunciates detector status operating normally the LED flashes every four seconds the device is in alarm it is steady on operation detector will check the alarm status once every 10 seconds smoke falls below the alarm threshold the alarm condition clear within 10 seconds Combustible storage facilities Munitions manufacturing Volatile chemical storage Chemical processing plants Petroleum refineries Turbine enclosures Battery rooms HVAC applications external wiring to the device is connected inside the integrated box The 30 3013 has ports for up to four conduit entries port accepts conduit with 3 4 inch NPT in mm in mm and Maintenance Diagnostics normal operation the detector performs a self test function in the background once per second Detection is interrupted during the test and no indication is given if the test If the test fails a Critical Fault condition will occur If sen drift is found to be approaching critical levels an Advisory condition will occur Testing on board magnetic switch is used to initiate the Manual Self The LED will light when a magnet is detected at the switch test will immediately check the smoke chamber optics for degradation there is a failure the LED will shut off immediately after the one test and a Trouble condition will occur If the test passes Alarm will be annunciated while the LED remains active The will clear after 10 seconds 2 of 4 D A T A S H E E T K85001 0645 to be used for installation purposes Issue 1.1 proper temperature rated cabling type and diameter for input as well as output signal wiring Terminals accept 14 to 18 shielded stranded copper wire field wiring terminal connections are certified for a single wire size from 0.2 to 2.5 mm2 or two conductors with the same section 0.2 to 0.75 mm2 The screws must be tightened with a torque 0.4 to 0.5 N The metal housing must be grounded minimum of 12 Vdc must be present at the 30 3013 to ensure operation The maximum cable length from power source 30 3013 is 2,000 feet 610 m When the 30 3013 Smoke De is mounted remotely using an STB termination box maxi cable length from 30 3013 to STB is 500 feet 152 m Terminals NO Aux COM Aux NC Aux NO Alarm COM Alarm NC Alarm COM Trouble NO Trouble 0 20 mA mA Vin Vin Vin Vin Voltage Consumption alarm relay relay relay Range Range Protection Output Options Material Approvals Approvals Vdc 24 Vdc nominal watts maximum 2.75 watts at 24 Vdc C 5 amperes at 30 Vdc normally closed contacts and normally operation A 5 amperes at 30 Vdc normally open and normally energized operation C 5 amperes at 30 Vdc normally open closed contacts and normally de operation to 65 to 149 to 70 to 158 to 95 relative humidity ceiling mount application only mA mA dc current with maximum resistance of 300 ohms from 12 17.9 Vdc ohms from 18 to 19.9 Vdc and 600 ohms for 14 18 AWG or 2.5 0.75 mm2 wire inch NPT or M25 Polycarbonate ABS Box Copper free aluminum painted I Div 1 Groups B C D T4 I Div 2 Groups A B C D T4 I Zone 1 AEX db ia IIC T4 Gb to 65 FEG15.0014X db ia IIC T4 Gb to 65 Information Smoke Detector Weight lbs 3.56 kg 3 of 4 D A T A S H E E T K85001 0645 to be used for installation purposes Issue 1.1 that saves lives us 888.244.9979 Option 4 kidde esfire com kidde fire carrier com is a Carrier brand Town Center Pkwy FL 34202 2020 Carrier rights reserved 4 of 4 D A T A S H E E T K85001 0645 to be used for installation purposes Issue 1.1

Related Files