KFRTI-20/52 A MANUAL Company Foster Avenue, Wheeling, IL 60090-6574 847 f 847 e-mail [email protected] Internet www.kfco.com RISK OF ELECTRICAL SHOCK. READ THIS INSTALLATION MANUAL COMPLETELY BEFORE OR SERVICING PANELS. CHASSIS MUST BE CONNECTED TO EARTH GROUND. OBSERVE HOT AND NEUTRAL POLARITY WHEN CONNECTING AC DO NOT APPLY AC OR BATTERY POWER DURING INSTALLATION. AVOID INSTALLATION IN DIRECT SUNLIGHT AND IN RAIN RUNOFF DO NOT INSTALL CONDUIT INTO THE TOP SURFACE OF THE SELECTION- LOCATE AND INSTALL THE PANEL SO THAT VIBRATION OR WILL NOT CAUSE ACCIDENTAL OPERATION. MOUNT PANEL ON A STRUCTURALLY SOUND WALL. GENERALLY, LOCATION IS A WALL AREA CONVENIENT TO RUN THE FOR ZONE INPUTS, ANTENNA, AND AC POWER THE PANEL SHOULD BE LOCATED TO PROVIDE; A CLEAR VIEW OF AN ARC OF 16 FOR PANEL DOOR CLEARANCE, OF SWITCHES, AND MAINTENANCE OPERATIONS. Company Foster Ave., Wheeling, IL. 60090-6574 847 f 847 e-mail [email protected] Internet: www.kfco.com OF ENCLOSURE shall be undertaken only by properly skilled, trained and qualified professionals who are in modern industrial installations and all applicable codes and requirements. all instructions first. not connect batteries or apply power until wiring and installation is complete and checked. Co. equipment must be installed in accordance with NFPA-72 / NFC codes, The Electric Code, the Local Authority Having Jurisdiction and King-Fisher Co. manuals and a suitable position and structure for mounting the enclosure. REMOVE the subplate(s) assembly from the enclosure by removing the four (4) nuts and washers (8) nuts & washers KFRTI-52 panel REMOVE the mouting hole knockouts located at the rear of the enclosure. HOLES HOLES HOLES Company Foster Ave., Wheeling, IL. 60090-6574 847 f 847 e-mail [email protected] Internet: www.kfco.com 75853 05/01 1 MOUNT the enclosure on a wall using appropriate hardware shown. Use stainless steel hardware for the enclosure in accordance with proper installation requirements. MOUNT HARDWARE all conduit necessary to the enclosure. must NOT enter through the top of enclosure. Knockouts are provided on the and bottom of the cabinet. DO NOT knockouts with sub-plate(s) installed. conduit to the enclosure using water- fittings with star locknuts. DO NOT reducing washers. S.S. SCREW S.S FLAT WASHER separate conduit runs are required: Power Inputs and Audibles Coax Cable Reinstall sub-plate(s) and secure with 4 nuts washers (8 nuts & washers in KFRTI-52 panel). Remove all PC boards. Slide each circuit board out, one at a time, and lay them down in order on a dry, non-conductive surface. Keep all circuit boards and zone boards in sequence as they are coded for proper transmission. MOUNTING SIDE VIEW (SIDE VIEW) ANCHOR Mtdg. Detail WIRING ZONE LUG 2 75853 05/01 Company Foster Ave., Wheeling, IL. 60090-6574 847 f 847 e-mail [email protected] Internet: www.kfco.com WIRING wiring must be based on current NFPA ( National Fire Protection Association) and NEC (National Code) standards. Due to varying local and/or other building, electric, and fire codes, it is highly that the installer review all applicable codes in addition to NFC (National Fire Codes). and final acceptance of system installation shall be subject to the authority having jurisdiction. drawing 76807, 76810, 76803-1, and 76806-1 while reading the following instructions. Dress field wiring around the bottom and right sides of the enclosure. Pull AC wiring into the cabinet. The KFRTI-20/52 panel operates on 120 VAC. 50/60Hz. single phase Connect HOT and NEUTRAL to terminals. This panel requires a 15 Amp/120 VAC Circuit or fused circuit to be installed external t