Radionics - D9024 D10024 Fire Control Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

D9024 and D10024 Analog Fire Alarm Control Panels Instructions material and instructions covered in this manual have been carefully checked for accuracy and are to be reliable However the manufacturer assumes no responsibility for inaccuracies and the right to modify and revise this document without notice instructions cover the installation of the D9109A Enclosure and the installation of the D9024 or system components within it See the Fire Alarm Control Panel Operator Manual for on powering up and operating the system and Cautions Notices is used in these instructions to indicate procedures to follow to avoid injury used in these instructions to indicate procedures to follow to avoid damage to 15 equipment has been tested and found to comply with the limits for a Class A digital device pursuant Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful in a commercial installation This equipment generates uses and can radiate radio energy and if not installed in accordance with the instructions may cause harmful to radio communications However there is no guarantee that interference will not occur in a installation If this equipment does cause harmful interference to radio or television reception can be determined by turning the equipment on and off the user is encouraged to try to correct the by one or more of the following measures Reorient or relocate the receiving antenna Connect the equipment into an outlet on a circuit different from that to which the receiver is the separation between the equipment and the receiver Consult the dealer or an experienced radio TV technician for help Notices UL listed for NFPA 72 Local references to NFPA and related requirements are based upon compliance with the 1993 edition of 72 National Fire Alarm Code Since installation specifications are nearly always based upon a specific of a standard which has been legally adopted by the Authority Having Jurisdiction AHJ earlier of NFPA standards will generally apply Consult with the appropriate AHJ for confirmation Radionics All rights reserved The Radionics logo is a registered trademark of Radionics 1800 Abbott Street Salinas CA 93901 USA 01 97 Installation Page 1 of 17 of Contents 1 and Cautions 1 Notices 1 D9109A Enclosure Installation 4 A 1 Semi flush Mounting 4 A 2 Surface Mounting 4 Circuit Connections 5 B 1 Polling Circuit D9067 5 B 2 Peripheral Circuits 6 B 3 Notification Appliance Indicating Device and Output Circuit Connections 6 Control Panel Components 7 C 1 Control Module 7 C 1 a Control Module Installation 7 C 1 b Front Panel Display Connection 7 C 2 D9067 Polling Circuit Module 8 C 2 a D9067 Module Installation 8 C 2 b D9067 Module Connection to the Control Module 9 C 2 c D9067 Module Connection to Class Style 4 Circuit 9 C 2 d D9067 Module Connection to Class Style 6 Circuit 10 C 2 e Shielded Cable 10 C 3 D9051 RS 485 Bus Module 10 C 3 a D9051 Module Installation 11 C 3 b D10024 Attachment Points 11 C 3 c D9024 Attachment Ports 11 C 3 d D9051 Module Connection to the Control Module 12 C 3 e Connecting Circuit Wiring to the D9051 12 Power 12 D 1 AC Power Connections 12 D 2 D1605 Transformer 13 D 3 Standby Batteries Installation 14 D 3 a Standby Battery Selection 14 D 3 b Battery Wiring Connections 15 D 4 System Startup 15 Normal Operation 17 E 1 Normal Power and Polling Activity 17 E 2 Trouble or Fault Conditions 17 E 3 Alarm Conditions 17 E 4 Resetting the System 17 E 4 a Trouble Fault Reset 17 E 4 b Alarm Reset 17 Radionics All rights reserved The Radionics logo is a registered trademark of Radionics 1800 Abbott Street Salinas CA 93901 USA 01 97 Installation Page 2 of 17 of Figures 1 D9109A Enclosure and Removable Door 4 2 Ground Location on Control Module 5 3 Output Connection Points on the D9024 and D10024M Control Module 6 4 D10024M Control

Related Files