Siemens 5128 5129 Digital Fire Communicator Connected to the MXL Control Panel5128 5129 Digital Fire Communicator, Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

OPERATION Instructions Knight Model 5128 5129 Fire Communicator Connected to the Control Panel for the MXL Manual MXL from Siemens Industry Inc reports system to a Central Station using the Silent Knight 5128 5129 a four channel digital communica that reports alarm trouble supervisory and status When used with the MXL the Knight Model 5128 5129 uses the alarm and supervisory channels The miscellaneous channel may be used to annunciate conditions other fire at the Central Station RATINGS all system power before installation battery and then AC To power up the AC first and then the battery Knight Model 5128 the Silent Knight Model 5128 within the MXL Alternate mounting for the Silent Knight may include double sided tape velcro or Knight Model 5129 Silent Knight Model 5129 must be mounted to the MXL Control Panel and within 20 feet it using electrical conduit MXL Control Panel connects to the Silent Model 5128 5129 Digital Fire Communicator the Alarm Trouble and Supervisory dry on the MXL Main Board See Figure 1 to the Silent Knight 5128 5129 Fire Slave Installation Manual P N 150805 with the Silent Knight Model 5128 5129 for instructions Silent Knight Model 5128 5129 monitors all troubles through the MXL trouble relay The delays the AC fail trouble signal in accordance NFPA and UL requirements NFPA 72 Remote Station install batteries to 60 hour standby capacity For signalling DACT wire according to the Figure 1 NFPA 72 Central Station connections AC fail is delayed The delay is typically 6 hours of 24 hours Only the reporting of the trouble delayed power must be present for a full minute before system switches back to AC power from the the optional AC monitor input See Figure 1 Silent Knight Model 5128 5129 monitors AC fail When the MXL System reports an AC fail the Silent Knight Model 5128 5129 sends a code to the Central Station that identifies the as AC fail to the MXL MXLV Manual P N 315 092036 MXL System information Industry Inc Technologies Division Park NJ 315 093294 7 Building Technologies Ltd Safety Security Products Kenview Boulevard Ontario 5E4 Canada Silent Knight Model 5230 LCD Keypad Program can be connected temporarily to Pin P4 on the Knight 5128 Main Board See Figures 1 and 2 on site programming or troubleshooting of the English language messages assist in data changing the 24 hour test time and conditions currently in effect 1 lists the recommended program for the Silent 5128 5129 Digital Fire Communicator Before begin programming read the Step Program Form in the Silent Knight Model 5128 5129 Slave Communicator Installation Manual P N provided with the Silent Knight 5128 5129 Knight Model 5128 5129 Programming Table 1 No Option Name Option Name ACTIVE SUPERVISED CHANNEL INPUT CHANNEL INPUT CHANNEL RESPONSE 1 RESPONSE 2 RESPONSE 3 RESPONSE 4 1 CODE CODE TYPE ENABLE LINE 1 LINE 2 REPORT 1 REPORT 2 MONITORING LOSS HOURS See Note 2 Note 4 See Note 2 ALARM CODE TROUBLE CODE RESTORE CODE TEST CODE SPRINKLER SUPERVISORY 1 FIRST 1 FIRST 1 FIRST 1 1 1 1 2 2 2 2 ACCOUNT PHONE TIME TIME See Note 2 See Note 2 No 1 2 3 4 5 6 7 8 9 the selection is left blank the user must fill in the proper information Skip No selection is required After each selection is made press the ENTER key to proceed to the next step a For Systems Configured as NFPA 72 Local enter 6 hours For Systems Configured as NFPA 72 Auxiliary or Remote Station enter 15 hours

Related Files