Siemens 5128 5129 Digital Fire Communicator Connected to the SXL-EX Control Panel, Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

OPERATION Instructions Knight Model 5128 5129 Digital Fire Connected to the Control Panel for the SXL EX Manual SXL EX Control Panel reports system to a Central Station using the Knight Model 5128 5129 a four chan digital communicator that reports alarm supervisory and miscellaneous When used with the SXL EX the Knight Model 5128 5129 uses the trouble and supervisory channels miscellaneous status channel may be to annunciate conditions other than fire the Central Station 84mA 18 40 VDC 154mA 18 40 VDC Knight Model 5128 the Silent Knight Model 5128 within SXL EX enclosure as shown in Figure 1 Knight Model 5129 Silent Knight Model 5129 must be outside of the SXL EX enclosure within 20 feet of it All electrical wiring be in metal conduit Safety all system power before first battery and then AC power up connect the AC first then the battery SXL EX Control Panel connects to the Knight Model 5128 5129 Digital Fire using the Alarm and Trouble contacts on the SXL EX Main Board See 2 The Supervisory dry contact is by using either the SZE 4X or the dry contact relay to follow any SXL EX event Refer to the SXL EX Installation and Maintenance P N 315 095997 for programming Also refer to the Silent Knight Fire Slave Communicator Installation August 1994 P N 150805 provided the Silent Knight Model 5128 5129 for instructions Silent Knight Model 5128 monitors all troubles through the SXL EX trouble The SXL EX delays the AC Fail trouble in accordance with NFPA and UL NFPA 72 remote station connections 60 hour backup battery capacity The SXL EX Control Unit delays the AC trouble transmitted by the Silent Model 5128 5129 dialer for 6 hours Building Technologies Inc Fernwood Road Park New Jersey 07932 315 093223 7 Building Technologies Ltd Kenview Boulevard Ontario L6T 5E4 Canada Silent Knight Model 5230 LCD Keypad can be connected temporarily to P4 on the Silent Knight 5128 Main Board Figure 1 for on site programming or of the communicator English messages assist in entering data the 24 hour test time and describ conditions currently in effect 1 lists the recommended program for Silent Knight 5128 5129 Digital Fire Before you begin program read the Step Programming Form in Silent Knight Model 5128 5129 Fire Slave Installation Manual August P N 150805 provided with the Silent 5128 5129 Knight Model 5128 5129 Programming Table 1 Option Name Option Name ACTIVE SUPERVISED CHANNEL INPUT CHANNEL INPUT CHANNEL RESPONSE 1 RESPONSE 2 RESPONSE 3 RESPONSE 4 1 CODE CODE TYPE ENABLE LINE 1 LINE 2 REPORT 1 REPORT 2 MONITORING LOSS HOURS See Note 2 Note 4 No ALARM CODE TROUBLE CODE RESTORE CODE TEST CODE 1 FIRST 1 FIRST 1 FIRST 1 1 1 1 2 2 2 2 ACCOUNT PHONE TIME TIME See Note 2 See Note 2 See Note 2 No 1 2 3 4 5 6 7 8 9 the selection is left blank the user must fill in the proper information Skip No selection is required After each selection is made press the ENTER key to proceed to the next step a the Silent Knight Model 5129 Digital Fire Communicator is used enter a from 0 to 15 hours the Silent Knight Model 5128 Digital Fire Communicator is used enter 0 NUT Remove hex nuts from the 4 studs on the of the SXL EX door Place the 5128 over the studs as shown the diagram Attach each of the 4 hex nuts to each of studs as shown the Silent Knight Model 5128 in the EN SX SXL EX Enclosure 1 CONTACT SZE 4X OR MODULE 1 2W 5 140 820388 Four EOLRs P N 140 820388 not provided These 4.7K 5 EOLRs are needed full installation For remote station provide 60 battery back up capacity 1 2W 5 140 820388 1 2W 5 140 820388 4 and Negative Ground Fault at 20K For Terminals on TB3 DC POWER 1 RING GREEN Knight 5230 NOT USED NC C NO Knight Model Fire Communicator 1 TIP RED 1 TIP GRAY 1 RING BROWN RJ31X 2 TIP GRAY 2 TIP RED 2 RING GREEN RJ31X 1 2W 5 140 820388 CHANNEL INPUTS 2 RING BROWN to Silent Knight Model 5128 5129 Wiring Diagram 2 315 093223 7

Related Files