Siemens ABHW-4B Audible Base (with Loop Power Option), Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

s Sheet Safety Products Bases Audible Sounder Base with Loop Power Option ABHW 4B AND ENGINEER SPECIFICATIONS Innovative two wire loop power option Highly flexible programming and configuration options independently controlled outputs by device Provides six 6 field configurable audible tone patterns Steady American National Standards Institute ANSI Temporal 3 ANSI Temporal 4 Carbon Monoxide CO March time 120 and Canadian March time 30 Synchronization by loop Power options include NACs Loop two wire Siemens PAD series NAC Extenders Model ZIC 4A for FireFinder XLS FACPs Any other UL Listed 24VDC regulated power supply Overview Model ABHW 4B Audible Sounder Base from Siemens Fire Safety is an intelligent supervised and addressable base designed for use in standard applications in an audible notification device is required The Model base generates a 3,000 Hz audio signal that with NFPA 72 Standard used with a Desigo intelligent detector Model which is UL ULC Listed has the option of powered directly from a signal line circuit SLC in a configuration In turn this connection feature each audible sounder base the distinction of being first base of its kind to attain agencies approval loop power feature and advanced configuration contained with each audible sounder base are available when a Siemens Model detector is Conversely Model ABHW 4B will function similar to of a Model ADBH 11 audible base when a Model or detector is used innovative loop power option provides easier two wire for new or expansion applications where wiring or power options are limited View View Compatible with Desigo Fire Safety intelligent devices and and addressable detectors Standard 3,000 Hz Buzzer tone UL268 UL464 UL2075 Listed ULC S525 S529 Listed 3150 3230 3010 CSFM 7300 0067 0271 Approved Model ABHW 4B can be powered in a four wire configuration utilizing a notification circuit NAC a Siemens PAD series NAC Model ZIC 4A or any UL Listed 24VDC power supply See the Model ABHW 4B Installation and Operation IOM A6V10405587 for further details ABHW 4B provides six 6 field configurable tone two 2 volume levels are used with compatible intelligent addressable detectors and FACPs Temporal 3 pattern Temporal 4 pattern Temporal with low power March Time 120 and Canadian March 30 are supported by each audible sounder base sounder bases wired in the same device loop are fully synchronized with the Desigo Fire Safety S and C Line detectors and support Siemens Remote Models RL HC and RL HW used in conjunction with agency listed compatible fire components Model ABHW 4B may be used in of a single multiple station smoke alarms to achieve system level functionality Industry Inc Technologies Division ABHW 4B Audible Sounder Base 6159 audible sounder base consists of a standard Siemens Fire Safety Series detector base layout combined supportive circuitry for Desigo Fire Safety and Model of addressable detectors ABHW 4B houses a pre wired audible sounder capable of generating a 3,000 Hz tone that provides signal up to 85dBA at 10 feet 3.1m for localized options are available to provide power to the Model audible base Additionally all Model ABHW 4B are capable of sounding simultaneously individually in any combination depending upon the system used on a Siemens FACP For power and wiring options see IOM A6V10405587 ABHW 4B is a UL ULC Listed supplementary device that meets or exceeds the 85dB at ft 3.1m audibility requirement specified in UL268 ULC S529 as well as UL464 UL2075 for 520 Hz low frequency tones with s FACPs ABHW 4B functions with the following panels XLS FC2005 Type Machine Interface PMI or later or later Loop Card Model DLC or later 50 point addressable FACP 24 v01.02.16 53 v6.0.0R1 or later FC2025 FC2050 Data smoke detectors used with Model ABHW 4B are to the maximum 30 ft center spacing sq ft as referred to in the National Fire Association Standard 72 This spacing is based on ideal conditions namely ceiling no air movement and no physical between the fire source and the device center spacing format should be referred to as a for detector installation layout Do not mount in areas close to ventilating or air conditioning It is mandatory for NFPA 72 guidelines to be to detector placement and spacing Data Cross Cable 18 AWG Wire Gauge 2 back end blocks of up to four screw terminals on each side Data continued Voltage Current Current max Humidity Output Box Power 16 33 VDC Power 16 33 VDC SLC Loop 250 External Source 20 dBA 7.5 mA dBA 4.5 mA dBA 8.0 mA dBA 3.5 mA 120 49 95 85 dB 75 dB 10.2 cm square gang box A 4 10.2 cm octagon box is not compatible with Model ABHW 4B for Ordering S54320 F13 A1 Sounder Base Loop Power Option Audible Base tone C O O USA Intelligent Detectors Remote Lamps Detector Detector Heat Detector Heat Detector Optical Heat w CO Detector Series Detectors Remote Alarm Lamp Wall Remote Alarm Lamp Ceiling Optical Heat Detector Heat Detector Optical Detector Optical Heat Detector Heat Detector Optical Detector Models SFP 11 SFPO 11 and SFPT 11 detectors are approved in Canadian installations Model bases limited in audible base functionality Technical Support at 1 800 248 7976 for further details This marketing data sheet is not intended to be for system design or installation purposes Custom Configuration Software S54320 F13 A2 Industry Inc Technologies Division Safety Fernwood Road Park NJ 07932 973 593 2600 908 547 6877 www usa Siemens com Fire in U S A Safety North Service Road Oakville Ontario 0H6 Canada 905 465 8000 www Siemens CA 2016 sheet dated 3 2015 4

Related Files