
File preview
Click below to download immediately for free
File data
- Filename: 8421675930_Siemens_CP-35_Operation_&_Installation_Manual.pdf
- File size: 2 MB
- File type: pdf
- Download count: 38
Text Preview
Fire Safety CP CP CP CP CP-35 C C C CONONONONONTRTRTRTRTROLOLOLOLOL P P P P PANELANELANELANELANEL C MAINTENANCE MANU MAINTENANCE MANU MAINTENANCE MANUALALALALAL AND MAINTENANCE MANU MAINTENANCE MANU Building Technologies, Inc. Fernwood Road Park, New Jersey 07932 315-085063-20 Building Technologies, Ltd. Kenview Boulevard Ontario L6T 5E4 CN WIRING MUST BE DONE AS DESCRIBED BELOW, TO OBTAIN AND PROPER SYSTEM OPERATION Earth ground the System 3 enclosure see the latest edition of National Electrical Code for methods. Conduit ground NOT adequate. Separate all wiring for initiating (i.e., detectors, manual etc.) from all other wiring in System 3 enclosure. INSULATE ALL CABLE DRAIN WIRES any conduit or other earth electrical box, including in the System 3 enclosure. Connect shield cable drain wire ONLY the SPECIFIED location inside the 3 enclosure. Earth ground all conduit runs the installation. additional wiring information, to this manual or call Building Technologies, Inc. Support Department at 1 View of CP-35 Power Supply (PS-35) Modules Selected AND WIRING System 3 depends to a great reliability of the SIEMENS upon proper installation of the control panel, modules, associated equipment, and wiring. These instruc- outline the requirements for a satisfactory installation. completion of each detail provides an automatic and control system that is dependable and gives operation. terminals for the Control Panel are shown the WIRING DIAGRAM in the centerfold. The wiring for a typical system with control panel and is shown in Figure 3, TYPICAL SYSTEM WIRING. terminals for the individual modules are shown the Operation and Installation Instructions sheet pro- with each of the modules. questions regarding the equipment or installation be directed to the Siemens Building Technologies, Technical Support Group. the Control Panel Enclosure 2) fasten the control panel enclosure to a shock vibration-free surface in a clean, dry area. It should mounted with the top of the enclosure approximately feet above the floor. The location should ensure that control panel is easily visible and readily accessible for Leave sufficient room to open the door. should be in accordance with national and local for fire alarm circuits. Use the knockouts provided. AC supply power, use No. 14 or larger AWG, 600V wire. up the module/frame assembly by the straps provided the end of the wiring channels. Do not place hands the modules, as the circuitry may be damaged. the module/frame assembly in the enclosure, secur- it to the studs with the 5/16 inch nuts provided. Do not overtighten nuts (do not use ratchet wrench), as the studs can be broken if force is applied. Requirements CP-35 is designed to operate from the 24 VDC out- provided from the Model PS-35 power supply. Con- from the CP-35 to the power supply is made by a harness assembly. PS-35 power supply operates from a 120 volt, 50/60 three-wire, grounded neutral, power source. The power must be connected directly through separate or fuses, to the line side of the main power for the building. No other equipment may be sup- from these separate circuitbreakers or fuses. Wire run continuously from the AC power source to the input terminals. Refer to the WIRING DIAGRAM. the Control Panel and Power Supply the system power supply PS-35 in the upper right- corner of the enclosure. It oc