Silent Knight 6820EVS Intelligent Fire Alarm Control Panel with Emergency Voice System Data Sheet

File Preview
File Preview
Click below to download for free

Text Preview

6820EVS Fire Alarm Control Panel with Emergency Voice System 6820EVS panel and accessories provide to meet the requirements for Mass Systems as described in UL 2572 6820EVS is an intelligent addressable Fire Alarm Control Panel combined with an Voice System EVS and are direct replacements for the 5820XL EVS FACP the EVS features are enabled they are integrated with the fire alarm and voice functions of the control panel emergency voice system operations include an onboard supervised microphone All call non active call buttons can quickly select all active or non active output groups The also allows for emergency messages over fire 6820EVS FACP has one built in signaling line circuit SLC which can support 159 SK and 159 SK modules or 127 SD protocol devices Additional SLC loops can be for a maximum of 1110 SK or 635 SD points per panel built in digital alarm communicator transmitter DACT is dual technology IP and The POTS transmits system status alarms troubles AC loss etc to a Central Station the public switched telephone network The IP communicator internet monitoring sends alarm signals over the Internet saving the monthly cost of two dedicated telephone lines Although not required the secondary telephone line may be providing backup communication over the public switched telephone line Optional reporting is available 6820EVS has six onboard Flexput circuits that can be configured as notification or auxiliary power The 6820EVS also has a form C trouble relay and two form C relays along with powerful features such as drift compensation pre maintenance alert a built in sensor test to comply with NFPA 72 calibration testing and a calibration trouble alert common communications and annunciation link allows up to 17 panels to be connected copper or fiber optic cable A designated panel is configured as the communicator for all in the link for convenient single point communications AND BENEFITS Single enclosure for both fire and Selectable strobe synchronization for Two programmable relays and one fixed voice components Ability to select EVS messages as priority fire System Sensor Wheelock and devices Built in DACT with IP and optional cellular 15 Recordable one minute messages that be mapped to eight EVS buttons Built in USB interface for quick and easy Capable of producing 520 Hz tones to meet 72 requirements JumpStart auto programming reduces Support for up to 4 LOCs and 8 addressable time relay Compatible with SWIFT wireless devices Convenient field upgradeable firmware Network support for up to 17 sites Network card allows copper network with a multi mode or single fiber connection Real time clock calendar with automatic 999 software zones 999 output groups savings control Expandable SLC loops to 1110 SK or 635 flexible design options History file with 1,000 event capacity point capacity 23 preset notification cadence patterns Six Flexput circuits for NAC outputs or ANSI 3.41 power Allows up to 24 SBUS devices Four programmable function keys INTERFACE INDICATORS General Alarm Red Supervisory Yellow System Trouble Yellow System Silenced Yellow System Power Green 12 key numeric pad Acknowledge Alarm Silence System Reset Drill F1 F4 Programmable Function Keys 6820EVS system offers several options to simplify and expedite JumpStart auto programming minimizes required to start a new system The built in keypad or remote annunciators give on site access to current system System programming can also be accomplished the Windows Honeywell Fire Software Suite HFSS INFORMATION Addressable fire alarm control panel red EVS EQUIPMENT 50 Watt amplifier 125 Watt amplifier 50 100 Watt amplifier External backup amplifier 50 Watt internal amplifier Provides 4 additional audio circuits Remote voice module 24 switch expander Network voice control module Local operator console SBUS DEVICES 4x40 LCD remote fire annunciator with four programmable red 4x20 LCD remote fire annunciator gray 4x20 LCD remote fire annunciator red 4x20 LCD remote fire annunciator red LED annunciators display up to 30 LEDs 15 red 15 LED annunciators display up to 30 LEDs 15 red 15 Key switches for silence and reset and a system trouble LED LED I O module with 40 programmable LED outputs and supervised dry contact inputs Relay interface Provides 10 Form C relays 2 of 4 351606 D 3 31 2020 Serial Parallel printer interface module for printer connection COMPATIBLE ADDRESSABLE DEVICES SKand SD devices cannot be mixed in the same fire alarm Multi criteria photoelectric smoke detector with 135 fixed temperature Reflected beam smoke detector without test feature Reflected beam smoke detector with test feature Reflected beam smoke detector SK protocol Supervised control module Six circuit supervised control module Photoelectric duct smoke detector with extended air range Four criteria fire and carbon monoxide detector Four criteria fire and carbon monoxide detector Fixed thermal detector 135 Fixed thermal detector 135 white Fixed rate of rise detector Fixed high temperature heat detector 190 Fixed high temperature heat detector 190 Fixed rate of rise detector white Fault isolator module Mini monitor module Monitor module Dual input monitor module 10 input monitor module Photoelectric smoke detector Photoelectric smoke detector white Photoelectric detector with remote test capability Photoelectric det with remote test capability Photoelectric smoke detector with fixed heat 135 Photoelectric smoke detector with fixed thermal 135 white Multi criteria photoelectric smoke detector with thermal fixed temperature white Addressable single action pull station Addressable dual action pull station Addressable relay module Addressable Six relay control module Addressable Dual relay monitor module Addressable zone interface module Six zone interface module BASES 6 mounting base 4 Flangeless mounting base Intelligent sounder base 6A power supply with 6 Flexput circuits 2 Form C 6 amp NAC power expander with 4 power limited output ckts COMMUNICATORS Cellular communicator metal enclosure w lock Cellular communicator plastic enclosure Dual path fire alarm communicator cellular and or IP or backup selectable 2 Remote reporting via the Internet Requires a VisorALARM at the central station ACCESSORIES Network Interface Card Provides a common link for the IFP 300 Installation Accessory Kit Fiber Optic Multi Mode transmitter and receiver Fiber Optic Single Mode Remote battery box accessory cabinet Seismic compliance kit used to fasten batteries to the fire SOLUTIONS Silent Knight Selection Tool provides the installer or design with a Windows software system configuration to create a detailed bill of material BOM and battery Honeywell Fire Software Suite provides remote and local programming detector status event history and additional Databases can be uploaded downloaded via the panel USB using a flash drive Requires a PC running Microsoft Low frequency intelligent sounder base Relay base Isolator base COMPATIBLE ADDRESSABLE DEVICES SK and SD devices cannot be mixed in the same fire alarm Addressable 6 base Addressable 6 short circuit isolator base Addressable 6 relay base Addressable 6 sounder base Addressable input module switch input Addressable notification module Addr

Related Files