Silent Knight SK-Control Addressable Notification Module Manual

File Preview
File Preview
Click below to download for free

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS Supervised Control Module Clintonville Road Northford CT 06472 Fax 203.484.7118 Operating Voltage Current Draw Operating Current NAC Line Loss Ext Supply Voltage NAC on External Supply NAC Current Ratings Range to 32 VDC mA LED on LED flashing in group poll mode 350 LED flashing in direct poll mode 485 Max LED flashing NAC shorted VDC Terminals T3 and T4 24VDC mA Maximum using 24 VDC supply class B wiring system 3A For class A wiring system 2A to 120 0 to 49 to 93 Non condensing H x 4 W x 11 4 D Mounts to a 4 square by 21 8 deep box Electrical Box 1A CONTROLS AND 1B JUMpER LOCATION 2A MODULE MOUNTINg BARRIER 2B INSTALLINg information is included as a quick reference installation guide Refer to control panel installation manual for detailed system information If the will be installed in an existing operational system inform the opera and local authority that the system will be temporarily out of service Dis power to the control panel before installing the modules This manual should be left with the owner user of this equipment DESCRIpTION Supervised Control Modules are intended for use in intelligent systems where the individual address of each module is selected the built in rotary switches This module is used to switch an external supply to notification appliances It also supervises the wiring to the loads and reports their status to the panel as NORMAL OPEN or CIRCUIT The SK Control has two pairs of output termination points for fault tolerant wiring and a panel controlled LED indicator REqUIREMENTS ensure proper operation this module shall be connected to a compatible Knight system control panels only list available from Silent Knight SK Control mounts directly to 4 inch square electrical boxes see Figure The box must have a minimum depth of 21 8 inches Surface mounted boxes SMB500 are available All wiring must conform to applicable local codes ordinances and When using control modules in nonpower limited applications requirements for the separation of power limited and nonpower limited and wiring must be met The barrier must be inserted into a 4 4 21 8 junction box and the control module must be placed into the barrier attached to the junction box Figure 2A The power limited wiring must placed into the isolated quadrant of the module barrier Figure 2B Install module wiring in accordance with the job drawings and appropri wiring diagrams the address on the module per job drawings Secure module to electrical box supplied by installer as shown in 2A When using the SK Control for fire fighter telephone applica remove Jumper J1 and discard The Jumper is located on the back as in Figure 1B 3 TypICAL NOTIfICATION AppLIANCE CIRCUIT CONfIgURATION NfpA STyLE y NOT LOOP WIRE ON TERMINALS 10 11 BREAK WIRE TO PROVIDE SUPERVISION OF CONNECTIONS VDC CIRCUIT MODULES TO COMPATIBLE CONTROL ONLY VDC POWER SUPPLY REGULATED LIMITED PER NFPA 70 FOR FIRE PROTECTION BATTERY BACKUP POLARITIES ARE IN ALARM LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED PANEL PREVIOUS NEXT EOL LISTED EOL SHOWN VDC COIL NEXT CONTROL MODULE OR RELAY ONE RELAY FOR EACH CIRCUIT SOME PANELS HAVE RELAY BUILT AND DO NOT REQUIRE EXTERNAL REFER TO PANEL MANUAL WIRING SHOWN IS SUPERVISED POWER LIMITED ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE 4 TypICAL fAULT TOLERANT NOTIfICATION AppLIANCE CIRCUIT CONfIgURATION NfpA STyLE Z VDC CIRCUIT NOT LOOP WIRE ON TERMINALS 10 11 BREAK WIRE RUN TO PROVIDE OF CONNECTIONS MODULES TO LISTED CONTROL ONLY PANEL PREVIOUS POLARITIES ARE IN ALARM VDC POWER SUPPLY REGULATED LIMITED PER 70 LISTED FOR PROTECTION WITH BACKUP RESISTOR INTERNAL TERMINALS AND 9 LISTED EOL SHOWN VDC COIL NEXT CONTROL MODULE OR RELAY ONE RELAY FOR EACH CIRCUIT SOME PANELS HAVE RELAY BUILT AND DO NOT REQUIRE EXTERNAL REFER TO PANEL MANUAL WIRING SHOWN IS SUPERVISED POWER LIMITED ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE relay switch contacts are shipped in the standby state open state but may have transferred to the activated closed state during shipping To ensure that switch contacts are in their correct state modules must be made to communicate with the panel before connecting circuits controlled by the module LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED NEXT Honeywell International Inc

Related Files