Silent Knight SK-FIRE-CO-W Fire CO Detector Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name silent-knight-sk-fire-co-w-fire-co-detector-data-sheet-4281573609.pdf
Type PDF
Size 847.33 KB
Downloads

Text Preview

Addressable Devices Fire CO Detector Description is a plug in addressable device that provides both fire and carbon CO detection The detector combines four separate sensing elements to multiple components of a fire smoke CO light flame and heat This approach enhanced sensitivity to real fire with heightened immunity to nuisance For CO the detector electrochemical sensing cell creates a separate for life safety CO detection sensors and communication can greatly reduce nuisance alarms compared single sensing methods Sophisticated algorithms maximize the advantages of all sensor types creating our best detection strategy offering heightened immunity nuisance particulate and enhanced sensitivity to real fire Photoelectric sensors detect airborne particles associated with smoke Thermal sensors detect heat and rate of rise 135 fixed temperature threshold Infrared sensors discern light patterns in the environment as an additional data for alarm determination ability to reject certain nuisance alarm triggers such as theater smoke supports use of the fire CO detector in applications where moderate to heavy nuisance exist that might cause single sensing detectors to false alarm models meet UL 268 7th edition and UL 521 listing requirements for fire detection UL 2075 standard for system connected life safety carbon monoxide detection through the incomplete burning of various fuels CO is a colorless odorless deadly gas that is virtually impossible to detect with the human senses Because potential exists for dangerous levels of CO to accumulate in almost any building mandating the use of CO detection in commercial spaces continues to in B200S WH sounder base series intelligent sounder bases are recommended for use with SK FIRE CO W These bases can generate either a Temp 3 pattern for or a Temp 4 pattern for CO alarm indication The B200S series bases recognize the System Sensor synchronization protocol for use as a of the general evacuation signal along with other System Sensor Audible Visible devices when connected to a power supply or Alarm Control Panel FACP output capable of generating the System Sensor synchronization pulses BENEFITS Detects all four major Separate audible signal Automatic drift of a fire Separate CO detection fire or CO alarm used with a series base Highest nuisance immunity for and CO sensors New modern profile expanded color UL 268 7th edition UL and UL 2075 RealTest CO testing Uses only one address the SLC loop 10 year CO cell with warning Knight and RealTest registered trademarks of International Inc All rights reserved use of this is strictly document is not intended be used for installation We try to keep our information up to and accurate We cannot all specific applications anticipate all requirements specifications are subject to without notice of origin Mexico Technical Specifications INFORMATION Advanced multi criteria fire CO detector 4 Mounting base white 4 mounting base white 10 pack 4 Mounting base ivory 4 Mounting base black 6 Flanged mounting base white 6 Flanged mounting base white 10 pack 6 Flanged mounting base ivory Intelligent addressable sounder base white Intelligent addressable sounder base ivory Intelligent addressable sounder base white Intelligent addressable sounder base low ivory Isolator base white Isolator base ivory Relay base white Relay base ivory Surface mounting kit flanged Trim ring white Trim ring ivory IR color kit includes cover and trim ring white pack IR color kit includes cover and trim ring 10 pack IR color kit includes cover and trim ring 10 pack Remote LED annunciator Detector test magnet Telescoping test magnet 2.7 69 mm installed in B200S series sounder 6.875 175 mm installed in B200S series base 3.4 oz 95 g Humidity Range 15 to 90 Relative Non condensing Temperature Range 32 to 100 0 to Velocity 0 to 4000 ft min 0 to 1219.2 m min SPECIFICATIONS Voltage Range 15 to 32 VDC Current 24 VDC 200 uA one every 5 seconds with green LED blink on Alarm Current 2 mA 24 VDC one every 5 seconds with red LED solid on Current 4.5 mA 24 VDC one every 5 seconds with amber LED solid Load Rating 0.0063 MONITORING UL STANDARD REFERENCE thresholds in parts per million are as follows for 5ppm Detector response time 60 240 min 5ppm Detector response time 10 50 min 10ppm Detector response time 4 15 min UL standard 2075 the SK FIRE CO W has have been to the sensitivity limits defined in UL Standard Standard UL 268 7th Edition LISTINGS AND APPROVALS listings and approvals below apply to the SK FIRE In some cases certain modules may not be listed certain approval agencies or listing may be in process the factory for the latest listing status S6173 7272 0559 0517 Silent Knight Clintonville Road CT 06472 1610 A 05 19 Honeywell International Inc

Related Files