Silent Knight Technical Specifications of Intelligent Bases

File Preview
File Preview
Click below to download for free

Text Preview

INTELLIGENT BASES Relay Isolator Sounder and Low Frequency Sounder Bases meet local code and application requirements Silent Knight offers standard 4 and 6 as well as specialty base designs including relay isolator sounder and low frequency bases that are UL listed for low frequency operation and comply with NFPA 72 for sleeping spaces for the new SK W Series of addressable detectors as well as generations standard 4 and 6 bases offer a plug in detector base intended for use in intelligent with screw terminals provided for power and and remote annunciator Communication takes place over the power and lines The 4 base offers a design while the 6 base provides compatibility with a wider range of junction specialty bases support application driven requirements These bases employ a mounting plate that installs on various junction box sizes to eliminate unsightly boxes The mounting plate enables pre wiring of all connections to speed simplify installation bases B224RB WH B224RB IV provide one form C contact relay for control of functions such as door closure and elevator recall The relay can operate in two modes short and long delay The activation time for the short delay is 60 100 while the activation time for the long delay is 6 10 seconds A shunt with pin located on the base PC board is used to set the delay timing bases B224BI WH B224BI IV allow the Signaling Line Circuit SLC loop to under fault conditions created from a short circuit preventing an entire loop from being disabled The base isolates the section of the loop the short circuit from the remainder of the circuit and automatically restores the fault is corrected and low frequency LF sounder bases are designed for new and existing dwelling applications They offer maximum flexibility in installation configuration and operation meet or exceed UL 268 and UL 464 requirements The low frequency sounder bases are to meet the NFPA 72 sleeping space requirement to produce a fundamental of 520 Hz 10 with a square wave or its equivalent Studies show that a lower centered around 520 Hz is the most ideal to wake sleeping occupants even with mild to severe hearing loss Standard 6 Standard 6 White Ivory Sounder White Low Frequency Base White Flangeless Flangeless Base White Base Black AND BENEFITS Bases enable quick and secure detector Standard white color with ivory and black Sounder bases both UL268 and UL464 SEMS Screws provide easy wiring Mechanical locking feature restricts UL 268 compliant Support for 12 24 AWG provides flexibility of attached sensor head Specialty Base Features Pre wired mounting plate simplifies Multiple base formats meet application Application driven feature sets B200S sounder and LF sounder bases B200S WH B200S IV adopt the same address as the but use a unique device type on the loop The Fire Alarm Panel FACP can use that address to command an sounder or a group of sounders to activate The set from the FACP can be tailored to multiple event tone outputs allowing selection of volume 75 or 85 dBA ANSI Temporal 3 ANSI Temporal 4 or March Time and group addition some FACPs will enable custom tone patterns The series sounder bases recognize the System Sensor protocol This enables them to be used as a of the general evacuation signal along with other Sensor AV appliances when connected to a power supply FACP output capable of generating the System Sensor pulses B200SR sounder and LF sounder bases B200SR WH are fully compatible existing B501BH Series sounder base installations The device users to select one of two B501 supported tones ANSI 3 or Continuous through a jumper LINE INFORMATION BASES suffix indicates Ivory color model suffix indicates Black color model and suffix indicates White color model White 6 base standard flanged low profile mounting base base for the B210LP Bulk pack of B300 6 package contains 10 for the B210LPBP Ivory 6 base standard flanged low profile mounting base White 4 standard European flangeless mounting UL ULC listed Bulk pack of B501 WHITE contains 10 Black 4 standard European flangeless mounting base Ivory color 4 standard European flangeless mounting White relay base Ivory relay base White isolator detector base Ivory isolator detector base White Intelligent addressable sounder base capable of sound output in high or low volume with ANSI Temporal ANSI Temporal 4 continuous tone marching tone and custom Uses SK protocol Ivory Intelligent addressable sounder base capable of sound output in high or low volume with ANSI Temporal ANSI Temporal 4 continuous tone marching tone and custom Uses SK protocol White Low Frequency Intelligent programmable base produces a fundamental frequency of 520 Hz with a square wave or its equivalent designed to meet the 72 sleeping space requirement Ivory Low Frequency Intelligent programmable base produces a fundamental frequency of 520 Hz with a square wave or its equivalent designed to meet the 72 sleeping space requirement White Intelligent sounder base capable of producing output with ANSI Temporal 3 or continuous tone Intended retrofit applications Ivory Intelligent sounder base capable of producing output with ANSI Temporal 3 or continuous tone Intended retrofit applications White Low Frequency Intelligent programmable base produces a fundamental frequency of 520 Hz 10 a square wave or its equivalent designed to meet the NFPA 72 space requirement intended for retrofit applications Ivory Low Frequency Intelligent programmable base produces a fundamental frequency of 520 Hz 10 a square wave or its equivalent designed to meet the NFPA 72 space requirement Intended for retrofit applications KITS AND ACCESSORIES White replacement flange for B300 6 base Ivory replacement flange for B300 6 IV base Remote LED annunciator 3 32 VDC mounts to a U S electrical box For use with B501 and B300 6 Test magnet Test magnet with telescoping handle White detector color kit pack of 10 Ivory detector color kit pack of 10 Black detector color kit pack of 10 BOX SELECTION GUIDE Models B224RB depth contingent on base and wire size to National Electric Code or applicable local codes for appropriate recommendations to all model variants and See Product Line Information for detailed model description Gang Double Gang 3.5 Oct Square with 3.0 mud ring Square Oct mm mm mm mm 2 of 3 SK 61045 B 7 8 2019 BASES TECHNICAL SPECIFICATIONS B300 6 Series bases Operating voltage 15 to 32 VDC Standby current 170 maximum B501 Series bases Operating voltage 15 to 32 VDC Standby current 150 maximum B200 Series bases External supply voltage 16 to 33 VDC FWR Standby current 500 maximum Alarm current for B200S IV WH gauge B224BI B224RB 14 to 24 AWG B300 6 B501 B200S B200SR12 to 24 AWG range B224BI B224RB B200S B200SR 32 to 0 to 49 Knight and System Sensor registered trademarks of Inc document is not intended to be for installation purposes We to keep our product information and accurate We cannot all specific applications

Related Files