Simplex 2099 Series; 4099-9805 NO GRIP Retrofit Kit Manual Stations (D) (B) (C)

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Peripherals Non Coded Non Addressable Manual Stations Series Single and Double Action Operation fire alarm stations for general purpose Operation complies with ADA requirements Pull lever protrudes when alarmed Break rod is supplied use is optional Screw terminals for wiring connections Tamper resistant reset key lock keyed same as fire alarm cabinets Model key operated only types include Single action Double Action Breakglass or Push Type Optional NO GRIP Single Action Retrofit Kits are with a more easily operated pull lever for where anticipated users may find the station lever difficult to activate Optional Local Alarm cover Optional pre signal and annunciator contacts mounting options Surface or semi flush with standard boxes or matching boxes Flush mount adapter kit listed to Standard 38 of the Simplex single action manual stations a firm downward pull to activate the alarm switch the action breaks an internal plastic break rod below the pull lever use is optional The use of a can be a deterrent to vandalism without interfering the minimum pull requirements needed for easy The pull lever latches into the alarm position and extended out of the housing to provide a visible Action Stations Breakglass require the to strike the front mounted hammer to break the and expose the recessed pull lever The pull lever then as a single action station Action Stations Push Type require that a loaded interference plate marked PUSH be pushed to access the pull lever of the single action station reset requires the use of a key to reset the manual lever and deactivate the alarm switch If the break is used it must be replaced testing is performed by physical activation of the lever Electrical testing can be also performed by the station housing to activate the alarm switch Action Station Action Push Type GLASS Action Breakglass Fire Alarm Option Action Station with Cover NO GRIP kit Continued Stations activate by key operation only access for manual alarms to be initiated by personnel Operation requires key insertion opening of the station cover Action Station NO GRIP Retrofit Kit For applications such as California Building Title 24 which requires and operating shall be operable with one hand and shall not tight grasping pinching or twisting of the wrist model 4099 9805 Retrofit kit provides a more easily pull lever compared to standard stations Refer to page 2 for models with MEA acceptance These products have been by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the Health and Safety Code See CSFM Listing 7150 0026 175 Pull Boxes and NO GRIP Retrofit Kit for allowable values and or conditions concerning presented in this document It is subject to re examination revision and possible Additional listings may be applicable contact your local Simplex product for the latest status Listings and approvals under Simplex Time Recorder Co are property of Tyco Fire Protection Products 5 2012 Operation Continued Pre Signal Option activates when the lever is pulled alarm initiation requires a key to activate a located behind the pull lever Reset requires the use of a key to reset the station lever and deactivate the alarm switch the break rod is used it must be replaced requires physical activation of the pull lever for institutional stations Reference to NFPA 72 the National Fire Alarm and Signaling and all applicable local codes for complete for manual stations Product Selection Action Models General Alarm Application Reference Continued following summarizes the basic requirements Stations shall be located in the normal path of exit distributed in the protected area such that they unobstructed and readily accessible Mounting shall be with the operable part not less than in 1.07 m and not more than 48 in 1.22 m floor level At least one station shall be provided on each floor stations shall be provided to obtain a distance not more than 200 ft 61 m to the station from any point in the building When manual station coverage appears limited in any additional stations should be installed N O N C Alarm Action Models General Alarm N O N C Retrofit Kit for field conversion of a single action station to a NO GRIP station reference Instructions 579 1007 Replacement breakglass standard English Replacement break rod Flush adapter kit black refer to page 4 Flush adapter kit beige refer to page 4 Replacement retaining clip for breakglass Red surface mount box sheet metal 5 3 16 H x 4 W x 2 3 16 D 127 mm x 102 mm x 56 mm Red cast aluminum surface mount box 5 H x 3 7 8 W x 2 3 16 D 127 mm x 98 mm x 56 mm These models can be semi flush mounted using a standard single gang 2 1 2 64 mm deep switch box DO NOT RECESS BOX box flush or with 1 16 2 mm maximum protrusion These models can also be surface mounted on a Wiremold box model V5744S 4 5 8 H x 2 7 8 W x 2 1 4 D 117 mm x 73 mm x 57 mm cover kit For surface mount these models require 2975 9178 or 2099 9022 boxes For semi flush mount these models require a 4 mm square box with a single gang cover plate see diagram on page 3 Additional Manual Station Reference Manual Stations Sheet Addressable Manual Stations Data Sheet Standard Addressable Stations for hazardous locations Ring Pull Addressable for Releasing housing and explosion proof weather proof stations T Handle S2099 0009 Wire Guard addr non addr S2099 0004 5 2012 Surface Mounting Reference Box H x 4 W x 2 3 16 D mm x 102 mm x 56 mm separately located and bottom Cast Box H x 3 7 8 W x 2 3 16 D mm x 98 mm x 56 mm separately 2975 9178 box for reference DOWN View cover open for access mm for 3 4 threaded located top and bottom 25.4 mm 95 mm Semi Flush Mounting Reference Gang Box Mount gang box 2 1 2 deep mm RACO 500 or equal by others Square Box Mount 102 mm square box 2 1 8 54 mm minimum RACO 231 or equal supplied by others flush or with 2 mm extension NOT RECESS Square box cover plate DOWN gang cover plate 3 4 mm extension RACO 773 equal supplied by others view gang outline surface Mount Side View 5 2012 must be recessed into wall to 1 1 8 25.4 mm to 29 mm mount adapter kit Black Beige cutout must be a of 6 H by 5 W 152 mm by 127 mm Flush Mount Reference mm Specifications 121 mm 171 mm

Related Files