Simplex 4004 Fire Alarm ™ City Connect Card and DACT Module Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

Cautions and Warnings Fire Alarm Connect Card and DACT Module Installation Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of carton for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components use the 553 484 Control Kit Keep uninstalled components wrapped in anti static material at all times FREQUENCY ENERGY This equipment generates uses and can radio frequency energy and if not installed and used in accordance with instruction manual may cause interference to radio communications It has tested and found to comply with the limits for a Class A computing device to Subpart J of Part 15 of FCC Rules which are designed to provide protection against such interference when operated in a commercial Operation of this equipment in a residential area may cause in which case the user at his own expense will be required to take measures may be required to correct the interference 4004 Fire Alarm System is capable of supporting either one City Connect 565 577 565 999 or 566 078 or one DACT module This publication the procedure for installing a city connect card into a 4004 Panel It also the procedure for re installing a 2080 9044 DACT into a 4004 Panel for jobs new DACT installations use the 4004 9810 DACT 565 626 Refer to the Closure DACT Digital Alarm Communication Transmitter Installation Instructions 574 049 for more information on the 4004 9810 Page Connect Card Installation Module Installation This Publication following topics are covered in this publication 1999 Simplex Time Recorder Co Gardner MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice B Connect Card Installation Circuit 1 plugs and P3 all wiring information use the 4004 Field Wiring Diagram 841 992 Also the Contractor Wiring Termination Label 519 698 inside the 4004 Panel The label shows the following information The installation location of the city connect card The location of the wiring harness Harness interconnection with the system card The location of the city disconnect switches Programming information necessary to configure the card mount the city connect card follow Steps 1 through 3 while referring to 1 Disconnect 4004 Panel power at the breaker before the city connect card Remove the city connect card from the packing material the city connect card by securing it with four 6 Torx screws Connect the Cable Harness 733 875 from the City Connect Card P1 to System Board P5 or operation plug P6 1 1 CITY1 CITY2 CITY2 1 City Connect Card Circuit 2 plugs and P5 Switches and SW2 on 565 577 and only The are not present 566 078 on next page Connect Card Installation Continued Settings city connect card has jumper settings that select either the Remote Station Polarity Interface see Table 1 which is the default jumper setting the factory or the Municipal Master Local Energy Interface Jumper to configure the city connect card for the Remote Station Interface or Municipal Master Interface are listed below The city connect card has that illustrates the jumpers and selectable configurations Reverse Polarity Local Energy 1 Jumper Settings Master Energy Station Polarity to P2 2 to P3 8 to P3 10 to P4 2 to P5 8 to P5 10 to P2 3 to P3 2 to P3 4 to P3 6 to P4 3 to P5 2 to P5 4 to P5 6 Circuit 1 Circuit 2 City Circuit 2 can also be selected for Remote Station Supervisory or Operation See Table 2 by setting the following jumpers City Circuit 2 is selected for Trouble Operation City Circuit 1 Alarm only 2 Operation of City Circuit 2 Operation Operation to P6 2 to P6 4 to P6 3 Settings City Connect Card 565 577 and 565 999 only has two disconnect service SW1 and SW2 the normal position for both switches is the active position City Connect Card 566 078 does not have these switches and Configuration the 4004 System and configure the city connect card using the instructions located on the Termination Wiring Label inside the door Module Installation and Information The following installation procedures are for the Silent Knight 5128 only Tape Mounting Method Steps 1 through 11 and refer to Figure 2 to mount a DACT module using Tape Disconnect power for the 4004 Panel at the breaker installing the DACT module all wiring information use the Field Wiring Diagram 841 992 DACT mount to the 4004 Back Box in a physical location where the DACT LEDs can be viewed from a cutout slot opening on the mounting plate Contractor Wiring Termination Label 519 698 located on the inside of the door panel does not directly indicate where the DACT module should be Instead the label illustrates the optional City Connect Card in the area the cutout slot is located to view the DACT status LEDs The door label provides the programming information to configure the DACT into the System are two installation methods to mount the DACT module to the 4004 Box using either VHB tape or screw mounting Use the appropriate method for your installation If possible install the DACT before field wiring on the 4004 system cards When installing the DACT module be careful not to non power limited and power limited wiring removing or installing the mounting plate to from back box Lay the mounting plate on a non conductive free table when installing DACT module Remove the module from its packing material Locate the DACT module onto the back box back wall so the green ON LED yellow TROUBLE LED and red LINE 1 and PHONE LINE 2 LEDs are over the cutout slot on the mounting plate Using a pencil trace the DACT module locations onto the back box back wall Remove the two bottom 6 Torx screws and loosen the two top 6 Torx that secure the 4004 Control Panel Mounting Plate to the back box Carefully remove the mounting plate from the back box by lifting it upward the plate left past the locking tab and forward to release the plate from back box Attach two 8 inch long strips approximate of double sided VHB tape to the back of the DACT module lengthwise Remove the protective paper and position the DACT module where the tracing marks are located Ensure the LED windows are over the slot opening on the mounting plate and that the TELCO wiring is at the top of the cabinet on next page Module Installation Continued Tape Mounting Method Mounting Method Steps 1 through 11 and refer to Figure 2 to mount a DACT module using self tapping screws Cut and strip the green Earth connect wire on the DACT module and to the 4004 Back Box using an 18 AWG green wire and wire nut the circuit ground connection from P1 1 of DACT The ground is provided through Wiring Harness 733 897 supplied the mounting plate onto the back box by positioning the right side of plate behind the locking tab Secure the plate with four 6 Torx screws Connect Wiring Harness 733 897 from System Board P5 to DACT P2 P5 and TB1 Power up and configure the 4004 System for the DACT module using the instructions located on the Contractor Wiring Termination 519 698 on the door Program the DACT in accordance with the installation programming that is supplied with the DACT Remove the module from its packing material Locate the DACT module onto the back box wall so the green

Related Files