Simplex 4090-9121 Security Monitor IAM - Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

Cautions and Warnings Label Switch Re sealable Label Security Monitor IAM Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of carton for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components Keep uninstalled component wrapped in anti static material at all times addressable 4090 9121 Security IAM monitors normally open or normally contacts on contact closure security devices The Security Monitor IAM four state status information OPEN NORMAL ABNORNAL and to the 4100U Fire Alarm Control Panel FACP via the IDNet The IDNet channel provides the communication link between security IAM and FACP and powers the circuit range of possible temperatures under which the 4090 9121 Security IAM function are between 0 C 32 F and 49 C 120 F 4090 9121 Security IAM operates normally under non condensing humidity up to 93 with relative humidity at 32 C 90 F Monitor IAM installation consists of the following Setting the Security Monitor IAM address Making electrical connections to the Security Monitor IAM Mechanically installing the Security Monitor IAM Note or Zone Input View View The LED flashes approximately once every three seconds to indicate communications with the FACP 1 4090 9121 Security Monitor IAM Assembly 2001 Simplex Time Recorder Co Westminster MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice is a trademark of the Simplex Time Recorder Company B the Security Monitor Address The IDNet channel supports address codes 1 through 250 Security Monitor IAM has a unique address The address of the Security IAM is set via an eight position dip switch Figure 1 DIP switch 1 is the least significant bit LSB and position 8 is the most significant MSB Set the Security Monitor IAM address using Figure 2 as reference a small screwdriver or pen to set the switches The device address for the Monitor IAM should be written on the re sealable label this provides an aid in troubleshooting the system DIP switch in position is while DIP switch in position is IS SHOWN SET AT ADDRESS 7 ON OFF SWITCHES 5 THRU 8 1000 0100 1100 0010 1010 0110 1110 0001 1001 0101 1101 0011 1011 0111 1111 128 144 160 176 192 208 224 240 129 145 161 177 193 209 225 241 130 146 162 178 194 210 226 242 131 147 163 179 195 211 227 243 116 132 148 164 180 196 212 228 244 117 133 149 165 181 197 213 229 245 118 134 150 166 182 198 214 230 246 119 135 151 167 183 199 215 231 247 120 136 152 168 184 200 216 232 248 121 137 153 169 185 201 217 233 249 122 138 154 170 186 202 218 234 250 123 139 155 171 187 203 219 235 124 140 156 172 188 204 220 236 125 141 157 173 189 205 221 237 126 142 158 174 190 206 222 238 127 143 159 175 191 207 223 239 2 Security Monitor IAM Address Chart the Security Monitor IAM to the 4100 panel using the 4100 Fire PC Programmer Programming Manual 574 849 Configuration Electrical Connections the Security Monitor IAM and output signals connect to the Security Monitor IAM via terminals 1 4 illustrated in Figure 1 Terminal connections for the IAM are illustrated in 3 Do not loop wire under terminals Break wire runs to supervision Shield Wiring IAM Next IDNet Notes to 5 Series Initiating Devices Normally Closed Switches Device Notes IDNet Wiring Method Shield IAM Device Note 3 Next IDNet Note 3 to 5 Parallel Initiating Devices Normally Open Switches Resistor Harness Assembly Part No 733 973 Resistor Harness Assembly Part No 733 093 Resistor Harness Assembly Part No 733 092 When connecting two wires to one terminal position one wire on each side of the screw Maximum allowable run from FACP to farthest device not to 2500 feet Maximum total wire including all T Taps from FACP is 10000 IDNet lines are 18 AWG twisted pair shield recommended The Security Monitor IAM counts as three unit loads maximum number of Security IAM devices is 83 per channel Maximum wire length 18 AWG is 500 feet Only dry contacts are allowed on the device wiring is supervised and Power Limited both IDNet wiring methods shown are appropriate for the wiring of normally open or closed switches 3 Security Monitor IAM Connections Installing the Monitor IAM the Security Monitor IAM into a UL Listed single gang 4 inch square or octagonal electrical box not supplied using Figure 4 as a reference the Security Monitor IAM to the electrical box as follows the Security Monitor IAM into the electrical box the attached field wiring the IAM in place inside the electrical box Secure the cover to the back box using the two 6 32 flathead screws Listed Box 2 Minimum Depth Supplied Wiring for Blank Plate and Screws Supplied Monitor IAM Simplex offers semi flush and surface covers ordered separately with light pipe The cover s with light pipe allow viewing of the LED without taking the cover off Installation of the semi flush cover and 4090 9807 surface cover are detailed publication 4090 IDNet Semi Flush Surface Covers and IAM Installation Instruction 574 796 4 Security Monitor IAM Back Box Installation B

Related Files