Simplex 4098-5214, 920080, 920081, 920082 MX Technology Addressable Duct Sensor Housing and sampling tubes (B)

File Preview
File Preview
Click below to download for free

Text Preview

Listed Technology Addressable Devices Addressable Duct Sensor Housing 4098 5214 the 4098 5202 Photoelectric Sensor air duct sensor housing with clear to monitor for the presence of smoke an internally mounted base for use with a Photoelectric Sensor sensor is ordered Compatible with Simplex fire alarm control panel series 4100ES 4010ES or 4100U equipped an MX Technology Addressable Loop Module Clear cover allows visual inspection Sampling tubes ordered separately are available in lengths to match duct size UL listed to Standard 268A Analog sensor information is communicated to the host panel for accurate analysis module options ordered separately alarm LED 2098 9808 Please note that smoke detection in air ducts is intended to provide of the presence of smoke in the duct It is not intended and will not replace smoke detection requirements for open or other non duct applications 4098 5214 duct smoke sensor housing allows a MX Technology smoke sensor to monitor for conditions in air conditioning or ventilating ducts sampling tube selected per duct width is installed into duct allowing air to be directed to the smoke sensor in the housing and is discharged back into the via the exhaust tube Description Sensor Construction The MX 4098 5202 sensor provides robust and reliable which has undergone stringent environmental Electrical contacts are molded into the plastic to movement Construction uses durable fire FR110 plastic Sensors communicate to the MX Loop Module using Technology communications Additional listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property of Fire Protection Products Sensor Housing Front View Information Reference to NFPA 90A Standard for the Installation of Air and Ventilating Systems NFPA 72 the Fire Alarm and Signaling Code the NEMA for Proper Use of Smoke Detectors in Duct and Installation Instructions 579 962 Addressing technology sensors and addressable devices are using the 801AP programming tool which a simple menu driven user interface that can increment addresses following each write This simple to use addressing technique misaddressing errors that often occur when coded are used 801AP address programmer can also change stored in a sensor or other addressable device memory which makes addressing errors easy rectify 12 2011 Sensor Details Photoelectric Sensor 4098 5202 Photoelectric Sensor incorporates a optical chamber design with a high signal to noise that provides resilience to dust dirt and small for reduced service cost Indicator Details Remote LED Indicator Remote LED Alarm Indicator Red LED provides a remote indication that the sensor is in Refer to Specifications on page 3 for Information Sensor Loop Module Instructions Duct Sensor Location Reference Damper OK Air not locate here air air Air not locate here or other bank OK mount if appropriate Duct inlet Duct Sensor Location Considerations Proper duct smoke detection location must ensure airflow within the duct housing Duct air velocity rating is 500 to 4000 ft min 2.54 to m sec Pressure differential between intake and tubes is required to be between 0.016 mm and 1.0 25.4 mm of water To avoid air turbulence a location of six duct widths from bends or inlets is desirable Ensure for test and service Proper Locations downstream side of filters to detect in the filters in return ducts ahead of mixing upstream of air humidifier and cooling coil Other locations and orientations may be required for duct smoke detection depending on duct system design and duct airflow testing to Avoid Where dampers closed for comfort control would with airflow Next to outside air inlets unless the intent is to smoke entry from that area return air damper branch ducts and mixing areas airflow may be restricted 12 2011 Product Selection Smoke Sensor Housing Duct Sensor Housing with internally mounted sensor base 7 178 mm exhaust tube sampling tube end mounting screws and mounting template requires 4098 5202 sensor and selection of a sampling tube Sensor One Required Per Sensor Housing Ordered Separately MX Technology Addressable Photoelectric Sensor for the 4098 5214 Tubes Ordered Per Duct Width One Required Per Sensor Housing Ordered Separately Length 762 mm 1524 mm 3048 m Width Range to 30 152 mm to 762 mm to 60 76 mm to 1524 mm to 120 1524 mm to 3048 mm Specifications Mechanical Environmental approximate Velocity Range linear ft min Listed Temperature Range Range Communications Connections Remote LED Indicator H x 8 W x 2 D 254 mm x 216 mm x 57 mm to 4000 ft min 2.54 to 20.3 m sec F to 100 F 0 C to 38 C to 85 RH non condensing Loop 1 address per sensor base blocks 18 to 14 AWG 0.82 mm2 to 2.5 mm2 or two 1.5 mm2 4 H x 2 W 114 mm x 70 mm holes 3 9 83 mm apart standard US single gang box mounting mA coded wire leads 18 AWG 0.82 mm2 12 2011 SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm are trademarks of the National Fire Protection Association NFPA Fire Protection Products Westminster MA 01441 0001 USA 12 2011 2011 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice

Related Files