Simplex 4098-9795, 4098-9796 TrueAlarm Multi Sensor 4098-9754 with Dual Address Bases (B) (C)

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Analog Sensing Dual Address Bases for Multi Sensor Standard and Sounder photoelectric sensing and TrueAlarm sensing combined in one housing TrueAlarm photoelectric technology accurately for smoke activity TrueAlarm thermal sensing accurately monitors for temperature and rate of rise temperature selected combined as required per sensor Basic operation is UL listed to Standard 268 Sounder operation is also listed to UL Standard 464 as audible notification appliance Standard Base 4098 9796 provides Two sequentially addressed points automatically with one address selection Connections for remote LED or LED tracking relay for alarm status indication Sounder Base 4098 9795 provides features of 4098 9796 and also provides Built in piezoelectric sounder with high output dBA and low current requirements 20 mA Sounder power can be from 24 VDC or from a Notification Appliance Circuit NAC Sounder output can be synchronized via or by the NAC if NAC powered Sounder operation can be independently activated from host control panel analog sensing operation Analog sensor information is digitally communicated to control panel via IDNet or MAPNET II two wire sensor information is processed by the host panel to determine sensor status use with the following Simplex products Model Series 4008 4010 4100ES 4010ES and 4100U alarm control panels Note 4008 Series fire alarm control panels provide a feature set refer to data sheet S4008 0001 Legacy models 4020 4100 4120 Series fire alarm panels and Universal Transponders equipped MAPNET II operation For use with 4100ES 4100U or 4010ES control panels 4098 9754 is also available using single bases refer to data sheet S4098 0024 for more including TrueSense early fire detection combining photo and heat inputs and architecturally styled enclosures for ceiling or wall mounting Smoke sensor louver design directs air flow to chamber Sound louvers on sounder base exit both front and side smoke capture high output sound Built in magnetic test feature alarms both addresses Designed for EMI compatibility Optional accessories include remote alarm LED or alarm LED tracking relay Multi Sensor 4098 9754 Mounted in Sounder Base 4098 9795 Multi Sensor 4098 9754 Mounted in Base 4098 9796 Multi Sensor Description multi sensor 4098 9754 combines the performances of a TrueAlarm photoelectric sensor with a fast acting and accurate TrueAlarm sensor to provide both features in a single assembly Communication of Analog Sensing information from each sensor is digitally to the control panel where it is analyzed sensor input is stored and tracked as an value with an alarm or abnormal condition being by comparing the sensor present value its average value Thermal data is processed to for absolute or rate of rise temperature as desired Data Evaluation Monitoring each sensor average value provides a software process that compensates for environmental dust dirt etc and component aging providing accurate reference for evaluating new activity The is a significant reduction in the probability of false nuisance alarms caused by shifts in sensitivity either or down This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation Accepted for City of New York Department of Buildings MEA35 93E Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Fire Protection Total quantity of sounder bases available for coding on the same communications channel vary with panel application and availability of NAC power Refer to specific control requirements 9 2012 Description Continued Panel Selection Peak activity per sensor is to assist in evaluating specific locations The alarm point for each TrueAlarm sensor is determined at the panel selectable as more or less sensitive as the application requires Selection Alarm set points can be for timed automatic sensitivity selection as more sensitive at night less sensitive during Control panel programming can also provide operation per sensor For example a 0.2 may cause a warning to prompt investigation while a level may initiate an alarm Alarm and Trouble LED Indication Each base LED pulses to indicate communications the panel If the control panel determines that a is in alarm or that it is dirty or has some other type trouble the details are annunciated at the control panel that sensor base LED will be turned on steadily a system alarm the control panel will control the such that an LED indicating a trouble will return to to help identify the alarmed sensors Analog Sensor Features against rear air flow entry are EMI RFI shielded sensing Photoelectric sensing technology 360 smoke entry for optimum response Chamber screen provides protection from dirt dust insects sensing Fast response thermistor design Rate compensated self resetting operation Control panel can select per sensor for fixed sensing rate of rise temperature sensing the combination of both Sensing photoelectric sensors use a stable pulsed LED light source and a silicon photodiode to provide consistent and accurate low power sensing Seven levels of sensitivity are available each individual sensor ranging from 0.2 to 3.7 per of smoke obscuration Sensitivity is selected and at the fire alarm control panel sensor head design provides 360 smoke entry for smoke response Because of the photoelectric technology the 4098 9754 sensor is UL listed for velocity of up to 4000 ft min However care must be in determining sensor locations to avoid areas local airflow may also impact any smoke flow to the application reference section on this page Heat Sensing heat sensors monitor a fast reacting thermistor operation that is self restoring and rate Due to its small thermal mass the sensor and quickly measures the local temperature for at the fire alarm control panel The control panel alarm selection to be per sensor as fixed or rate of rise temperature or the of both temperature detection is selectable at the panel for either 15 F 8.3 C or 20 F 11.1 C minute Fixed temperature sensing is independent of sensing and selectable to operate at 135 F C or 155 F 68 C In a slow developing fire the may not increase rapidly enough to operate rate of rise feature However an alarm will be when the temperature reaches its selected fixed setting heat sensors can be programmed as a utility to monitor for temperature extremes in the range 32 F to 122 F 0 C to 50 C This feature can freeze warnings or alert to HVAC system Refer to specific panels for availability Reference locations should be determined after careful of the physical layout and contents of the to be protected Refer to NFPA 72 the National Fire and Signaling Code On smooth ceilings smoke spacing of 30 ft 9.1 m may be used as a guide detailed application information refer to 4098 Sensors and Bases Application Manual Part 574 709 Dimension Reference 164 mm output louvers extend front and side with 4098 9795 Multi Sensor Sounder Base 124 mm mm status indicator mm status indicator

Related Files